CS Paper Radar

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan, Chang-Fu Su, Eng-Che Huang, Yuan-Ren Cheng

cs.SD ·submitted 2026-10-27 11:46 UTC · v1

Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

Closest papers

Nearest neighbours by meaning across the whole index.

Listening for Airway Stenosis: A Foundation Model-Based Method for Rapid and Accessible Detection

cs.SD ·2026-09-14 ·Jean Groeninger, Zihao Zhao, Juliana de Castilhos, Sven Nebelung, Daniel Truhn
code/data similarity 0.69
Abstract · Jean Groeninger and Zihao Zhao contributed equally. Code is available at https://github.com/JeanGrng/listening-for-airway-stenosis

Airway stenosis can cause severe respiratory complications, yet its detection often relies on specialized examinations and medical imaging. This study explores the potential of acoustic AI for rapid and accessible airway stenosis detection using readily acquired patient voice recordings. We systematically investigate whether acoustic foundation models (AFMs) can extract acoustic representations associated with airway stenosis-related speech patterns. Experiments are conducted on a cohort of 748 participants from the Bridge2AI-Voice dataset, 134 with airway stenosis and 614 without. The best-performing model achieves an AUROC of 0.952 and an accuracy of 0.924 (means over five-fold cross-validation), highlighting the potential of AFMs to transfer beyond general-purpose speech applications to clinical diagnostic tasks. Further analysis reveals that the model primarily relies on connected-speech recordings rather than isolated acoustic tasks, such as sustained phonation and breathing. Overall, these results suggest that voice-based acoustic AI could complement existing diagnostic workflows by enabling rapid, low-burden, and widely accessible screening for airway stenosis.

0.43

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.68
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.18

WIPSNet: Deep Learning for Paediatric Wheeze Detection from Overnight Impedance Pneumography

cs.LG eess.SP ·2026-09-30 ·Felix Oury, Harley Day, Karina Mayoral, Ville-Pekka Seppä, Sejal Saglani +1 more
publishedcode/data similarity 0.64
Abstract · Accepted at the Workshop on Structured Data for Health, ICML 2026. Code: https://github.com/felix-oury/WIPSNet

Overnight impedance pneumography (IP) is used to monitor paediatric respiratory health. Its current clinical readout, the Expiratory Variability Index (EVI), compresses each IP recording into a single scalar and achieves an AUC of 0.633 for night-level wheeze classification. We introduce Wheeze Impedance Pneumography Scalogram Network (WIPSNet), a 3D ResNet operating on stacked continuous wavelet transform scalograms of overnight IP signals. On a 15-patient cohort (60 nights, 281 hours), WIPSNet achieves an AUC of $0.783 \pm 0.026$, outperforming EVI, a state-space model (Mamba), and two modern sleep-staging architectures. Performance peaks at a volumetric depth corresponding to 32 minutes of temporal context, suggesting that multi-scale temporal aggregation is important for modelling nocturnal respiratory dynamics. Overall, these results indicate that structured time-frequency representations combined with 3D convolutional architectures provide an effective approach for learning from long, irregular physiological time series.

0.46

BreathGRU: A Novel Semi-Supervised Bidirectional Gated Recurrent Unit Framework for Speech and Breath Segmentation for Respiratory Audio

cs.SD cs.LGeess.AS ·2026-09-25 ·Sania Fatima Sayed, John W. Holloway, Reyer Zwiggelaar, Faisal I. Rezwan
similarity 0.62
Abstract

Speech-breath segmentation is a fundamental preprocessing step in respiratory audio analysis, enabling applications such as respiratory acoustic biomarker extraction, lung function prediction and disease monitoring. Existing approaches, including threshold methods, Fourier Transform-based techniques, and unsupervised and pretrained voice activity detection (VAD) models, primarily focus on speech detection and often classify breathing events as non-speech or silence, limiting their applicability for precise breath detection. To address this limitation, we propose BreathGRU, a semi-supervised Bidirectional Gated Recurrent Unit (BiGRU) framework specifically designed for speech-breath segmentation. The proposed framework combines frame-level acoustic feature extraction with bidirectional recurrent modelling, pseudo-label refinement and duration-constrained Segmental Viterbi decoding to produce speech and breath segmentation. BreathGRU was evaluated against the existing approaches, using manually annotated recordings. Performance was assessed using event-based, time-based, overlap-based, duration-based and boundary-based segmentation metrics. Experiment results demonstrated that BreathGRU achieved the highest breath event recall (0.83), the lowest onset-localisation error (0.14s) and the highest Mean Match Intersection over Union (0.81), with competitive overall segmentation performance compared to large pretrained VAD models like Silero. Qualitative evaluation on manually annotated recordings further showed close agreement between BreathGRU and manual annotation, with better breath detection compared to Silero. These findings demonstrate that explicit breath event modelling provides advantages over general-purpose VAD models and establish BreathGRU as an effective speech-breath segmentation framework which can be applied for respiratory audio analysis and pulmonary healthcare applications.

0.29

Analysis of Respiratory Sinus Arrhythmia with Neural Networks

cs.LG cs.AI ·2026-09-04 ·Julian Szymanski, Patryk Orkisz, Higinio Mora
top venue similarity 0.62
Abstract

The paper introduces a neural network-based approach for analyzing ECG signals to estimate respiratory rate by leveraging the phe- nomenon of Respiratory Sinus Arrhythmia (RSA). Our method employs a deep learning model trained to predict respiratory waveforms directly from ECG input data. To achieve this, we developed and evaluated three different neural network architectures capable of automatically extract- ing relevant features from ECG signals without the need for manual preprocessing. The proposed approach offers a robust and scalable solu- tion for non-invasive respiratory monitoring, with potential applications in healthcare and wearable technology

0.40

Metadata-Conditioned Audio Transformers for Adaptive Respiratory Sound Classification

cs.SD cs.AIeess.AS ·2026-11-02 ·George Kontogiannis, Pantelis Tzamalis, Sotiris Nikoletseas
publishedbenchmark similarity 0.61
Abstract

Respiratory sound classification from auscultation recordings is confounded by heterogeneous acquisition conditions, including recording device, auscultation site, and patient characteristics, that introduce systematic variability unrelated to the underlying pathology. Although such metadata is often available, existing approaches either ignore it or rely on naïve fusion strategies that do not model how distinct metadata sources influence different components of the acoustic representation. We propose a family of metadata-conditioning mechanisms for the Audio Spectrogram Transformer (AST), progressing from gated residual fusion to Feature-wise Linear Modulation (FiLM) adapted to the Transformer architecture. We further introduce two novel variants: Token-Aware FiLM (TAFiLM), which applies distinct modulation to classification and patch tokens, and Soft-Factorized FiLM (SoftFiLM), which learns soft masks to align metadata factors with disentangled feature subspaces. Experiments on the ICBHI benchmark demonstrate consistent gains across all conditioning strategies. SoftFiLM achieves 64.11% on the official 4-class task (+3.94% over the baseline) and 72.40% on the 2-class task, establishing a new state-of-the-art on the 2-class task and competitive performance on the 4-class benchmark.

0.24

RespFocus: Learning Temporal Evidence for Weakly Supervised Respiratory Sound Classification

cs.LG cs.AI ·2026-10-11 ·Yi Tian, Xiaohuan Chen, Yufei tang, Xinyu Lin, Hongliang Li +3 more
similarity 0.61
Abstract · 9 pages, 5 figures,2 tables

Respiratory auscultation provides a low-cost means of assessing pulmonary function, yet transient crackles and sustained wheezes can be difficult to recognize in noisy clinical recordings. Conventional deep learning classifiers often operate as black boxes, offering limited insight into the temporal acoustic evidence supporting their predictions. We present RespFocus, a weakly supervised framework that uses multiple instance learning (MIL) to learn inspectable temporal evidence from cycle-level labels and integrate it into classification. We also introduce PedResp2026, a multicenter pediatric respiratory sound cohort collected in routine clinical environments with adjudicated cycle-level annotations. In classification experiments, RespFocus achieves four-class Scores of 69.55\% on public ICBHI 2017 and 72.91\% on PedResp2026. Evidence diagnostics and matched temporal interventions support the functional contribution of the learned evidence to model predictions. Together, these findings highlight RespFocus's potential as a tool for automated respiratory sound diagnosis.

0.30

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.61
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13