CS Paper Radar

Analysis of Respiratory Sinus Arrhythmia with Neural Networks

Julian Szymanski, Patryk Orkisz, Higinio Mora

cs.LG cs.AI ·submitted 2026-09-04 20:09 UTC · v1
top venue

Abstract

The paper introduces a neural network-based approach for analyzing ECG signals to estimate respiratory rate by leveraging the phe- nomenon of Respiratory Sinus Arrhythmia (RSA). Our method employs a deep learning model trained to predict respiratory waveforms directly from ECG input data. To achieve this, we developed and evaluated three different neural network architectures capable of automatically extract- ing relevant features from ECG signals without the need for manual preprocessing. The proposed approach offers a robust and scalable solu- tion for non-invasive respiratory monitoring, with potential applications in healthcare and wearable technology

Closest papers

Nearest neighbours by meaning across the whole index.

A New AFIB Detection Method with Deep Neural Networks

cs.LG ·2026-10-29 ·Sara Gjorgjieva, Ana Angjelevska, Dimitar Trajanov, Marjan Gusev
benchmarkhot direction similarity 0.66
Abstract · 10 pages, 7 tables, 3 formulas

Early detection of atrial fibrillation (AFIB), characterized by irregular heart rhythms, can potentially save thousands of lives annually [20]. Numerous studies have attempted to address this challenge using various algorithms and methodologies. This paper introduces a novel and robust method that enhances the precision of AFIB detection. Neural Networks (NN) are widely recognized for their ability to identify complex electrocardiogram (ECG) patterns, facilitating the accurate detection of irregular heart rhythms. This study explores multiple conventional machine learning algorithms alongside neural network approaches to develop a robust AFIB detection system. To evaluate the effective- ness and robustness of the proposed method, the MIT BIH arrhythmia database (MITDB) and the Long-term Atrial Fibrillation Database (LTAFDB), both available on the Physionet site. Our approach presents a novel feature engineering technique, employing specific features such as a time series of the differences in successive heart rates (dBPM) rather than traditional inter-beat intervals. The model analyzes inputs labeled into five distinct classes, using only clean intervals identified through a new labeling method for training while treating others as outliers. This strategy ensures a more accurate and reliable AFIB detection process. The best-performing model, a Deep Neural Network (DNN), achieved an F1 score of 95.18% for binary atrial fibrillation classification on a benchmark dataset distinct from the training set. Models trained using our approach have demonstrated superior performance than previously published models.

0.47

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
similarity 0.65
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

cs.SD ·2026-10-27 ·Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan +3 more
similarity 0.62
Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

0.21

Accurate and Auditable ECG Classification via Visibility Graph Neural Networks

cs.LG cs.AI ·2026-10-30 ·Artur Xavier, Guilherme Henrique Gomes Evangelista, Aitazaz Khan, Antonio Luiz Pinho Ribeiro, Mohammed J. Zaki +2 more
hot direction similarity 0.62
Abstract · 43 pages, 10 figures, 21 tables, including Supplementary Information

Physicians read electrocardiograms (ECGs) from waveform shape and timing, yet accurate deep-learning classifiers rarely show which waveform regions drive their predictions. We introduce LYNX-ECG, a graph neural network that represents each heartbeat as a sparse visibility graph of timestamped turning points. On CODE-Test, LYNX-ECG reaches a macro F1 score of 0.889, outperforming five baselines including the ECGFounder foundation model, while its graphs need about 14% of the storage of graphs built from every sample. Because each node maps to a specific ECG time, we can delete clinically defined waveform regions and alter beat timing to audit predictions. For conduction disorders, the clinically expected region was the strongest evidence in more than 90% of correct predictions. Bradycardia and tachycardia calls follow heart rate with conduction intervals held fixed, and atrial fibrillation calls vanish when beat-to-beat variation is removed. Sparse visibility graphs thus pair accurate ECG classification with clinically grounded, testable explanations.

0.31

GNN-Enhanced TCN Algorithms for ECG Anomaly Detection

cs.LG ·2026-11-12 ·Angelica Simonetti, Ferdinando Zanchetta
published similarity 0.61
Abstract · Follow-up to arXiv:2310.02774, which introduced a pipeline for an industrial dataset. A shortened version of that earlier paper appeared in …

To a time series can be also given the structure of directed graph, opening the doors to the usage of graph neural networks (GNNs) in this context. In this paper we develop a new pipeline involving novel geometric deep learning models that merge the capabilities of ordinary TCNs with the ones of GNNs to solve an anomaly detection problem on electrocardiogram signals.

0.25

TinyCardioUNet: IMU-to-ECG Translation with Graph-Encoded Inter-Axis Dependencies and Tensor Decomposition-Based Parameter Reduction

cs.LG ·2026-09-24 ·Seungwoo Han, Ingon Chanpornpakdi, Motoi Noda, Puwadej Leelasiri, Ibuki Hiruma +1 more
code/data similarity 0.61
Abstract · The source code and pretrained models are available at https://github.com/ttlabtuat/TinyCardioUNet

Estimating electrocardiography (ECG) from a chest-worn inertial measurement unit (IMU) enables continuous heart rate (HR) monitoring without the discomfort of electrodes. We propose TinyCardioUNet, a lightweight UNet that uses all six IMU axes without prior channel selection, refines its bottleneck with a graph neural network that encodes inter-axis dependencies, and employs tensor decomposition with automatic variational Bayesian rank selection for parameter reduction. On a public dataset, TinyCardioUNet achieves an RMSE of $0.098$ and a Pearson correlation coefficient of $0.677$ with only $36.0$k parameters and remains comparatively robust to additive noise, demonstrating accurate ECG reconstruction with a compact model.

0.40

The Entropy Triangle Method (ETM): A novel framework for the prevention of cardiac arrhythmia with a review of more than 10,000 patients

cs.AI ·2026-09-24 ·Arman daliri
survey similarity 0.60
Abstract

One of the most important problems in medicine is to facilitate prediction. In this study, we propose entropy triangle method, a novel framework for predicting heart rhythms using a novel machine learning technique. This framework includes three steps: feature engineering, entropy triangle oversampling, and disease prediction. The dataset used in this study is a 12-lead electrocardiogram (ECG) arrhythmia research database with 10,646 patients. This dataset contains 11 different heart rhythms (5 sinus rhythms and 6 non-sinus rhythms). In this article, we introduce two firsts in machine learning and medicine that can predict non-sinus rhythm with over 85% accuracy. Our experimental results show, among others, that the most accurate classifier based on entropy triangles and the most useful oversampling are the supported vector classifiers and oversampling techniques for shark scent.

0.11

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
similarity 0.60
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28