CS Paper Radar

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady

cs.AI eess.SP ·submitted 2026-09-24 11:23 UTC · v1

Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

Closest papers

Nearest neighbours by meaning across the whole index.

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.70
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55

Analysis of Respiratory Sinus Arrhythmia with Neural Networks

cs.LG cs.AI ·2026-09-04 ·Julian Szymanski, Patryk Orkisz, Higinio Mora
top venue similarity 0.65
Abstract

The paper introduces a neural network-based approach for analyzing ECG signals to estimate respiratory rate by leveraging the phe- nomenon of Respiratory Sinus Arrhythmia (RSA). Our method employs a deep learning model trained to predict respiratory waveforms directly from ECG input data. To achieve this, we developed and evaluated three different neural network architectures capable of automatically extract- ing relevant features from ECG signals without the need for manual preprocessing. The proposed approach offers a robust and scalable solu- tion for non-invasive respiratory monitoring, with potential applications in healthcare and wearable technology

0.40

Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

cs.LG eess.SP ·2026-09-08 ·Athanasios Papastathopoulos-Katsaros, Alexandra Stavrianidi, Zhandong Liu
publishedbenchmark similarity 0.65
Abstract · Published at CinC 2026

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.

0.39

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.64
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

Interpretable Stress Detection from ECG Signals Using Motif-Based Anomaly Analysis

eess.SP cs.LG ·2026-08-27 ·Zhanna Balyan, Sachin Kumar
similarity 0.63
Abstract

Stress detection using physiological signals has gained significant attention due to its impact on both physical and mental health. While existing approaches based on machine learning and deep learning achieve strong predictive performance, they often rely on black-box models and fail to capture individual variability in physiological responses. In this work, we propose an interpretable and personalized framework for stress detection using electrocardiogram (ECG) signals based on motif discovery and Matrix Profile analysis. Instead of training a classifier, the method learns subject-specific baseline cardiac behavior by extracting recurring heartbeat patterns (motifs) from ECG signals. Stress is then detected as a deviation from these baseline patterns using a distance-based anomaly score. Experiments are conducted on the WESAD dataset using a carefully designed train-validation-test protocol to ensure reliable evaluation. The results show that the proposed approach can effectively detect stress for several subjects while providing clear interpretability through direct comparison of ECG patterns. However, the performance varies across individuals due to differences in physiological responses, with some subjects exhibiting minimal morphological changes under stress. Additional analysis incorporating heart rate variability (HRV) features reveals that while HRV can improve performance in certain cases, its contribution is not consistent across all subjects. These findings highlight the importance of personalization and interpretability in physiological stress detection and demonstrate that motif-based approaches provide a meaningful alternative to black-box models, while also revealing inherent limitations due to inter-subject variability.

0.23

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.62
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.61
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

DR-net-Mamba: Selective State-Space Modeling for Long-Range ECG Time-Series Denoising

cs.LG cs.AI ·2026-09-28 ·Basile Morel, Samuel Ruiperez-Campillo, Andreas P. Streich, Julia E. Vogt, Thomas Hofmann
similarity 0.61
Abstract · First three authors are co-first. Last two authors are co-last

Electrocardiogram (ECG) recordings are corrupted by non-stationary noise sources that degrade diagnostic reliability, particularly in ambulatory and long-duration recordings. Deep learning denoisers exist, but convolutional architectures are limited by their receptive field, transformer-based models scale quadratically with sequence length, and diffusion-based approaches incur prohibitive inference cost. We propose a Mamba-augmented model that inserts selective state-space blocks at the convolutional bottleneck, combining local feature extraction with long-range temporal modeling at linear complexity. We comprehensively evaluate the proposed model with respect to reconstruction fidelity, noise robustness, recording-length scaling, and downstream diagnostic classification across over 40 pathology classes. On synthetic and real datasets, our model achieves the highest SNR and lowest RMSE, with the Mamba advantage increasing with sequence length and in low-SNR regimes. On classification with two independent classifiers, the proposed Mamba-based models achieve the best macro AUROC among all denoisers and improve over their convolutional base models. Calibration is more nuanced and classifier-dependent: denoising improves Binary Cross-Entropy and Brier score on Inception1D but often fails to beat the noisy input on ResNet1D-Wang, and the lead-specific Mamba variant is the only denoiser to improve both calibration metrics over the noisy baseline on both classifiers. Per-class analysis reveals a morphology-dependent benefit: Mamba substantially improves ST/T-change diagnoses, which depend on broad, context-sensitive waveforms.

0.07