Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

Athanasios Papastathopoulos-Katsaros, Alexandra Stavrianidi, Zhandong Liu

cs.LG eess.SP ·submitted 2026-09-08 16:33 UTC · v2
publishedbenchmark

Abstract

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.

Comment
Published at CinC 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.71
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability

cs.LG ·2026-10-27 ·Bartosz Morawski, Samuel J. Ward, Alex Touze, Lin-Thiri Toon, Paul R. Roberts +2 more
benchmarkhot direction similarity 0.70
Abstract

This paper studies two non-transvenous implantable cardioverter-defibrillators (ICDs), namely the Subcutaneous ICD (S-ICD) and the Extravascular ICD (EV-ICD). Both avoid the complications of transvenous leads but are prone to oversensing, which can trigger inappropriate shocks associated with increased mortality. Oversensing risk is predicted by the ratio of T- or P-wave amplitude to R-wave amplitude (T:R, P:R), and these ratios vary over a 24-hour period. Yet S-ICD screening uses a single 10-second electrocardiogram (ECG) segment, and the EV-ICD has no formal screening protocol whatsoever. We present a 24-hour ambulatory screening framework for both devices which includes the first T:R analysis in an EV-ICD cohort and the first full evaluation of P:R prediction. We introduce AmpRatioNet, a family of 1D convolutional neural network architectures operating directly on the ECG signal, and benchmark it against the best existing approach - based on 2D phase space reconstruction images. Evaluation uses 4,605 clinician-annotated 10-second segments from 89 patients, with patient-level 10-fold cross-validation and bootstrap confidence intervals. AmpRatioNet-SE demonstrates superior performance on every metric in each setting with no device- or ratio-specific redesign. An explainability analysis against interpretable classical peak labelling algorithms shows that AmpRatioNet-SE's increase in error on oversensing-prone segments is up to 14 times smaller than theirs. Segment-level predictions are aggregated into a 24-hour timeline, extending S-ICD screening beyond 10 seconds and offering a plausible EV-ICD screening pathway pending device-level validation.

0.26

AF-Mamba: Efficient Long-Term Signal Modeling for Early Prediction of Atrial Fibrillation Onset

cs.LG ·2026-09-07 ·Yongbin Lee, Ki H. Chon
code/data similarity 0.69
Abstract · 11 pages, 5 figures, 7 tables. Extended version of IEEE BSN 2025. Code: https://github.com/yongbin98/AF_Mamba

Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with increased risks of stroke and heart failure. The growing availability of wearable and portable ECG monitoring enables continuous assessment of cardiac rhythm outside clinical settings. Predicting AF before its onset could provide additional lead time for timely clinical assessment and potentially improve the management of patients at risk of AF-related complications. This study focuses on predicting AF onset one hour in advance using long-term RR intervals (RRIs). To address this challenge, we propose a deep learning architecture that integrates temporal convolutional networks (TCNs) for local features encoding with Mamba, a selective state-space model capable of long-range sequence modeling. This hybrid TCN-Mamba design enables efficient training and inference on one-hour input windows, overcoming limitations of Transformers' quadratic scaling and recurrent networks' vanishing gradients. In subject-wise 5-fold testing, the proposed model achieved a sensitivity of 0.889, specificity of 0.943, F1-score of 0.813, AUROC of 0.974, and AUPRC of 0.933. In paired cross-dataset holdout evaluation, AF-Mamba maintained discriminative performance across unseen AF and NSR datasets, achieving a mean AUROC of 0.897. Compared against state-of-the-art AF prediction models and general time-series models, AF-Mamba achieved competitive predictive performance while providing a favorable performance-efficiency trade-off for long RRI sequences. These findings demonstrate the potential of AF-Mamba for accurate AF prediction one hour in advance and real-time continuous ambulatory monitoring.

0.38

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.69
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.20

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.67
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.21

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.67
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.67
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Bridging the Gap in ECG-Based Emotion Recognition: A Unified Evaluation of Deep Learning Models

eess.SP cs.LG ·2026-09-14 ·Timothy C Sweeney-Fanelli, Ajan Ahmed, Masudul Imtiaz
publishedbenchmarkcode/data similarity 0.67
Abstract · Accepted at 2026 IEEE 17th Annual Ubiquitous Computing, Electronics & Mobile Communication Conference (UEMCON) - 2026 IEEE UEMCON

Deep learning has led to numerous proposed architectures for Automated Emotion Recognition (AER) from electrocardiogram (ECG) data, but inconsistencies in preprocessing, training, and evaluation make direct comparisons difficult. Most studies train and validate models on individual datasets collected under homogeneous conditions, limiting variability and raising concerns about generalizability. Cross-dataset validation is sometimes used but primarily assesses model adaptability rather than true generalization. This study presents a comparative analysis of prominent deep learning architectures in AER, emphasizing model generalization over dataset adaptability. To enable this benchmark, we introduce two open-source frameworks: Affective Research on Representations and Classifications (ARRC), a standardized benchmarking toolkit, and Affective Research Dataset Toolkit (ARDT), a framework for inter-dataset training and validation. Using ARDT, we consolidate three publicly available AER datasets, CUADS, ASCERTAIN, and DREAMER, into a single dataset, increasing variability in sensor types, recording conditions, and participant demographics. We then use ARRC to evaluate three widely studied deep learning models and two CNN baselines through hyperparameter optimization and 10-fold cross-validation. Our findings provide insights into the trade-offs between classification accuracy and model complexity, establishing a reproducible benchmark for AER research. All source code for ARRC, ARDT, and model evaluation is publicly available to ensure transparency and facilitate further research.

0.37