CS Paper Radar

Bridging the Gap in ECG-Based Emotion Recognition: A Unified Evaluation of Deep Learning Models

Timothy C Sweeney-Fanelli, Ajan Ahmed, Masudul Imtiaz

eess.SP cs.LG ·submitted 2026-09-14 05:21 UTC · v2
publishedbenchmarkcode/data

Abstract

Deep learning has led to numerous proposed architectures for Automated Emotion Recognition (AER) from electrocardiogram (ECG) data, but inconsistencies in preprocessing, training, and evaluation make direct comparisons difficult. Most studies train and validate models on individual datasets collected under homogeneous conditions, limiting variability and raising concerns about generalizability. Cross-dataset validation is sometimes used but primarily assesses model adaptability rather than true generalization. This study presents a comparative analysis of prominent deep learning architectures in AER, emphasizing model generalization over dataset adaptability. To enable this benchmark, we introduce two open-source frameworks: Affective Research on Representations and Classifications (ARRC), a standardized benchmarking toolkit, and Affective Research Dataset Toolkit (ARDT), a framework for inter-dataset training and validation. Using ARDT, we consolidate three publicly available AER datasets, CUADS, ASCERTAIN, and DREAMER, into a single dataset, increasing variability in sensor types, recording conditions, and participant demographics. We then use ARRC to evaluate three widely studied deep learning models and two CNN baselines through hyperparameter optimization and 10-fold cross-validation. Our findings provide insights into the trade-offs between classification accuracy and model complexity, establishing a reproducible benchmark for AER research. All source code for ARRC, ARDT, and model evaluation is publicly available to ensure transparency and facilitate further research.

Comment
Accepted at 2026 IEEE 17th Annual Ubiquitous Computing, Electronics & Mobile Communication Conference (UEMCON) - 2026 IEEE UEMCON

Closest papers

Nearest neighbours by meaning across the whole index.

From Stress to Affect: Multimodal Deep Learning for Physiological Emotion Recognition Across Wearable Sensor Modalities

cs.LG ·2026-09-17 ·Desta Haileselassie Hagos, Saurav Keshari Aryal, Legand L. Burge
similarity 0.73
Abstract · Under review

Physiological emotion recognition using wearable sensors has important applications in mental health monitoring, affective computing, and human-computer interaction. However, existing studies typically evaluate a single model, sensing configuration, or dataset, limiting our understanding of how these factors influence recognition performance. We present a comparative study of temporal deep learning architectures for physiological emotion recognition using two multimodal wearable datasets: WESAD and EmoWear. Bidirectional long short-term memory (LSTM), temporal convolutional network (TCN), and Transformer models are evaluated under wrist-only, chest-only, and multimodal sensing configurations using participant-independent leave-one-subject-out cross-validation (LOSO-CV). We also investigate soft-voting ensembles, sensor ablation, sampling frequency, and gradient-based saliency. The Transformer achieved the highest multimodal accuracy on WESAD (99.02% +/- 0.51%), whereas the LSTM achieved the best multimodal accuracy on EmoWear for both arousal (91.80% +/- 1.06%) and valence (89.96% +/- 0.36%). These results show that relative architecture performance depends on dataset characteristics rather than one architecture being uniformly superior. Multimodal sensing consistently outperformed wrist-only and chest-only configurations across both datasets. Sampling-frequency analysis showed that 4 Hz provides a practical operating point, with performance comparable to higher frequencies at substantially lower training cost. These findings provide guidance for selecting architectures, sensing modalities, and sampling frequencies for wearable physiological emotion recognition.

0.09

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.72
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

EmoNet: A Lightweight Attention-Based CNN for Speech Emotion Recognition

cs.SD cs.LG ·2026-10-25 ·Muhammad Moiz Khalid, Abdur Rehman Tariq, Muhammad Okasha Yamin
published similarity 0.72
Abstract · 6 pages, 3 figures, 8 Tables

Speech Emotion Recognition (SER) is a fundamental task in affective computing that enables applications such as mental health assessment, human-computer interaction, and automated customer support systems. Accurate emotion classification from speech remains challenging due to variations in speaker style, acoustic conditions, and the high computational cost of modern deep learning approaches. Many existing systems depend on large transformer-based architectures that require substantial computational resources, making them less suitable for real-time or resource-constrained environments. This research proposes EmoNet, a lightweight deep learning framework for speech emotion classification across seven emotion categories. The model is built on a four-block depthwise separable CNN encoder with squeeze-and-excitation attention and residual connections, combined with a Bidirectional LSTM for temporal feature learning and a multi-head attention pooling mechanism for improved representation. A comprehensive 134-channel acoustic feature set alongside data augmentation techniques including audio-level perturbations and SpecAugment is employed to improve robustness under diverse acoustic conditions. Evaluated on a combined dataset of TESS, RAVDESS, and SAVEE, EmoNet achieves a test accuracy of 96.75% with only 4.11 million parameters. The proposed model outperforms its reproduced baseline and remains competitive with significantly larger state-of-the-art architectures.

0.19

Electrodermal Activity (EDA) for Stress Detection: A Comprehensive Survey and Benchmark

eess.SP ·2026-09-18 ·Gang Liu, Zixiong Ning
surveybenchmark similarity 0.71
Abstract · 19 pages, 5 figures, 7 tables

Electrodermal activity (EDA) is widely used for pervasive stress monitoring because of its sensitivity to sympathetic arousal and its computational efficiency. However, research remains fragmented: studies concentrate on a small subset of available datasets, preprocessing and evaluation protocols are inconsistent, and widely adopted methodological conventions remain unvalidated. Existing reviews summarize these practices without evaluating them under a common protocol. To bridge these gaps, this paper presents a comprehensive survey and benchmark for EDA-based stress detection. We review the technical pipeline from preprocessing to modeling and compile 26 public datasets and 22 representative unimodal studies to inform future dataset selection and methodological design. Under a subject-independent protocol spanning five diverse datasets, we benchmark decomposition, filtering, and channel-input choices alongside a broad range of machine learning (ML) and deep learning (DL) models in both in-domain and cross-domain transfer settings. Our results provide the first multi-dataset validation of cvxEDA, the default decomposition method, show that feature-based ML outperforms end-to-end (E2E) DL, and identify ecological validity as a key factor in cross-domain transfer. We conclude with directions toward robust, data-efficient, and trustworthy deployment.

0.22

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.69
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

SETEAB: Multiscale approach with Squeeze-and-Excitation Temporal Enhanced Aware Block for Speech Emotion Recognition

eess.AS cs.SD ·2026-09-05 ·Duy Vo, Kiet Anh Hoang, Hao Do
top venuebenchmark similarity 0.67
Abstract · Accepted to INTERSPEECH 2026

This paper proposes a novel lightweight multiscale architecture for speech emotion recognition (SER) with three key innovations. First, a depthwise convolution-based subsampling module is introduced to reduce model size and computation while preserving salient emotional cues. Second, a Squeeze-and-Excitation block is integrated to enhance channel-wise recalibration and improve representation robustness. Third, a new Temporal Enhanced Aware Block is designed to strengthen temporal dependency modeling and produce more discriminative emotion-aware features. The proposed model is explicitly designed to jointly improve compactness, recognition performance, and generalizability. Experiments on benchmark SER datasets show that our method achieves higher accuracy with reduced computational complexity, while also delivering stronger cross-corpus performance than most recent advanced networks for SER.

0.44

Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

cs.LG eess.SP ·2026-09-08 ·Athanasios Papastathopoulos-Katsaros, Alexandra Stavrianidi, Zhandong Liu
publishedbenchmark similarity 0.67
Abstract · Published at CinC 2026

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.

0.39

Beyond Accuracy: What Are Speech Emotion Recognition Models Learning?

eess.AS ·2026-10-24 ·Prince Baah-Mensah, Dennis Owusu Asamoah
similarity 0.66
Abstract · 6 pages, 4 tables

Speech Emotion Recognition (SER) is important in human-machine interactions, enabling machines to detect and classify human emotions from solely human speech. Speech emotion recognition (SER) benchmarks routinely report accuracies above 90 percent, yet these models fail when deployed or tested on diverse speakers. The papers overlook a fundamental issue: models may be learning speaker identity and tone rather than generalized emotional cues. We introduce a two-condition audit protocol that measures, for any published SER model, how much of its reported performance survives when speakers are held out. Each model is evaluated twice under identical architecture, features, and training recipe: a control condition that reproduces the common random-split practice, and a strict speaker-independent condition with disjoint speakers. We apply the protocol to seven model configurations from five published papers, spanning convolutional, recurrent, transformer, vision-transformer, and self-supervised wav2vec2 architectures, on RAVDESS, EMO-DB, and SAVEE, with a fourth corpus (EARS) as an external check. Across 21 model-dataset pairs, published headline numbers reproduce close to the control but drop by 6.9 to 63.1 percentage points under strict speaker independence. Our results quantify speaker memorization as a dominant, previously unmeasured component of published SER performance, and we recommend two-condition reporting as a community standard.

0.09