CS Paper Radar

X-Beat: An Explainable Framework for ECG Image Classification

Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore

cs.CV ·submitted 2026-09-18 22:34 UTC · v2
benchmark

Abstract

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

Comment
Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Closest papers

Nearest neighbours by meaning across the whole index.

How a Model's Architecture and Performance Influences Explainability: A Study of Grad-CAM and CRAFT in CNN-Based Image Classification

cs.CV cs.AI ·2026-11-09 ·Kilian Göller, Haadia Amjad, Steffen Seitz, Carsten Knoll, Ronald Tetzlaff
top venuehot direction similarity 0.73
Abstract · Accepted at the 4th World Conference on eXplainable Artificial Intelligence (xAI 2026), Fortaleza, Brazil, July 1-3, 2026. To appear in Spri…

Deep learning models, particularly convolutional neural networks (CNNs), are widely adopted in computer vision, yet their opaque decision-making raises concerns in high-risk applications like healthcare and autonomous systems, where trust and accountability are critical. Therefore, robust explainable AI (XAI) methods are desirable to provide transparent insights into model decisions. To ensure these methods are reliable and effective across diverse scenarios, it is important to understand how model performance and architectural complexity influence explanation quality. Our study takes an initial step toward systematically investigating the impact of these two factors on key XAI evaluation metrics. We constructed a pipeline using 10 subsets of ImageNet-1K, each containing 80 unique classes, on each of which we trained three CNN architectures of increasing structural complexity: VGG16, ResNet50, and ConvNeXt-Tiny. For each individual model, we analyzed 10 training checkpoints representing increasing levels of model accuracy using two XAI methods: Grad-CAM (feature-attribution-based) and CRAFT (concept-based). We assessed these methods across four evaluation categories: Faithfulness, Correctness, Sensitivity, and Simplicity. Our findings reveal that as training progresses, the complex architectures (ResNet50 and ConvNeXt-Tiny) exhibit improved Faithfulness and lower Sensitivity, indicating more robust explanations. In contrast, VGG16's simpler architecture yields simpler but less faithful and correct explanations.

0.39

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
similarity 0.72
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28

Interpretable Deep Learning Models for Breast Cancer Diagnosis Using Medical Imaging

cs.CV cs.AI ·2026-10-27 ·Sami Alnawali, Muhammad Atif Saeed, Abdul Hadi, Azka Atiq, Akhtar Jamil +1 more
benchmark similarity 0.71
Abstract · 37 page, 45 Figures

Deep learning shows promise for breast cancer diagnosis, but limited interpretability hinders clinical adoption. We benchmark ten ImageNet-pretrained models (ResNet50, VGG19, InceptionV3, DenseNet121, Xception, MobileNetV2, EfficientNet, ConvNeXt, ViT, and Swin Transformer) for benign-versus-malignant classification on the BreakHis histopathology dataset using a patient-level split, and explain their predictions with Grad-CAM, LIME, Integrated Gradients, and LRP. DenseNet121 performed best, with 99.4% test accuracy and an AUC-ROC of 0.999, and significantly outperformed all other models (p < 0.001). Transformer-based models trailed the CNNs. The explanations consistently highlighted nuclei-rich and glandular regions of diagnostic relevance. Combining transfer learning with explainable AI can thus yield accurate, interpretable tools for breast cancer diagnosis.

0.19

Cross-modal triage network: a multimodal deep learning framework for severity-based triage and visual explainability in chest radiographs

eess.IV cs.AIcs.CV ·2026-09-03 ·Zinah Ghulam, Richa Mittal, Eranga Ukwatta
benchmark similarity 0.70
Abstract

Purpose: Increased number of chest radiograph (CXR) scans create a triage bottleneck, queueing urgent examinations behind routine ones. Existing AI tools are predominantly unimodal binary classifiers lacking severity awareness, and multimodal systems are rarely benchmarked against expert radiologists. To this end, we developed a multimodal deep learning framework for joint severity triage, pathology detection, and native visual explanation. Approach: We propose the cross-modal triage network (CMTN), fusing a Swin Transformer V2 visual encoder with a PubMedBERT text encoder via gated cross-attention. The CMTN was trained on 34,639 image-text pairs (12,489 patients) from MIMIC-CXR-JPG, optimizing an ordinal focal loss for four-tier severity triage and binary cross-entropy for 14 pathologies. Beyond quantitative benchmarking, attention heatmaps were evaluated against a blinded expert radiologist in a two-phase clinical audit comparing model triage output to expert severity assessment (100 cases) and grading spatial-semantic concordance (116 heatmaps). Results: The CMTN achieved strong ordinal agreement with reference labels (quadratic weighted kappa [QWK] = 0.9341, 95\% CI: 0.9219 to 0.9449) and macro-AUROC of 0.9970 across 14 pathologies, with 34~ms latency, outperforming the state-of-the-art BioViL multimodal baseline (QWK = 0.7679). However, the blinded Phase I clinical audit revealed substantially lower agreement with genuine radiologist judgment (QWK = 0.1399). Phase II found 54.3\% of heatmaps achieved clinically acceptable spatial localization. Conclusions: The CMTN demonstrated an efficient multimodal architecture for CXR triage. The divergence between algorithmic and radiologist agreement demonstrates that benchmark performance against NLP-derived labels is insufficient, highlighting the need for radiologist-labeled ground truth before clinical deployment.

0.21

Bridging the Gap in ECG-Based Emotion Recognition: A Unified Evaluation of Deep Learning Models

eess.SP cs.LG ·2026-09-14 ·Timothy C Sweeney-Fanelli, Ajan Ahmed, Masudul Imtiaz
publishedbenchmarkcode/data similarity 0.69
Abstract · Accepted at 2026 IEEE 17th Annual Ubiquitous Computing, Electronics & Mobile Communication Conference (UEMCON) - 2026 IEEE UEMCON

Deep learning has led to numerous proposed architectures for Automated Emotion Recognition (AER) from electrocardiogram (ECG) data, but inconsistencies in preprocessing, training, and evaluation make direct comparisons difficult. Most studies train and validate models on individual datasets collected under homogeneous conditions, limiting variability and raising concerns about generalizability. Cross-dataset validation is sometimes used but primarily assesses model adaptability rather than true generalization. This study presents a comparative analysis of prominent deep learning architectures in AER, emphasizing model generalization over dataset adaptability. To enable this benchmark, we introduce two open-source frameworks: Affective Research on Representations and Classifications (ARRC), a standardized benchmarking toolkit, and Affective Research Dataset Toolkit (ARDT), a framework for inter-dataset training and validation. Using ARDT, we consolidate three publicly available AER datasets, CUADS, ASCERTAIN, and DREAMER, into a single dataset, increasing variability in sensor types, recording conditions, and participant demographics. We then use ARRC to evaluate three widely studied deep learning models and two CNN baselines through hyperparameter optimization and 10-fold cross-validation. Our findings provide insights into the trade-offs between classification accuracy and model complexity, establishing a reproducible benchmark for AER research. All source code for ARRC, ARDT, and model evaluation is publicly available to ensure transparency and facilitate further research.

0.57

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.69
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

cs.LG eess.SP ·2026-09-08 ·Athanasios Papastathopoulos-Katsaros, Alexandra Stavrianidi, Zhandong Liu
publishedbenchmark similarity 0.69
Abstract · Published at CinC 2026

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.

0.38

A Quantitative Evaluation Framework for Temporal Explainability in Echocardiographic Video Segmentation

cs.CV cs.LG ·2026-09-07 ·Jiyoo Noh, Jonathan H. Chan
similarity 0.69
Abstract · 15 pages, 5 figures

Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating temporal information. However, quantitative evaluation of temporal explainability remains largely unexplored. We propose a quantitative framework for evaluating Grad-CAM explanations using four complementary metrics measuring temporal consistency, saliency motion, anatomical overlap, and temporal overlap. Using EchoNet-Dynamic, we compare a baseline 2D U-Net with ConvLSTM U-Net models trained across multiple temporal strides. While segmentation performance remained comparable across all models, intermediate ConvLSTM explanations exhibited substantially lower saliency consistency and greater centroid motion than final prediction explanations. Temporal Bottleneck explanations were significantly more stable than Encoder Bottleneck explanations across all strides, while final ConvLSTM Decoder3 explanations were broadly comparable to those of the 2D U-Net. Importantly, conventional frame-wise explanation metrics cannot determine whether variation in intermediate explanations reflects meaningful temporal feature evolution or explanation instability. These findings establish a preliminary quantitative framework for temporal explainability and motivate temporal-aware XAI methods that explicitly account for evolving representations in medical video models.

0.23