CS Paper Radar

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman, Nabuat Zaman Nahim

eess.IV cs.CVcs.LG ·submitted 2026-10-26 20:58 UTC · v1

Abstract

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

Comment
18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Closest papers

Nearest neighbours by meaning across the whole index.

A New AFIB Detection Method with Deep Neural Networks

cs.LG ·2026-10-29 ·Sara Gjorgjieva, Ana Angjelevska, Dimitar Trajanov, Marjan Gusev
benchmarkhot direction similarity 0.73
Abstract · 10 pages, 7 tables, 3 formulas

Early detection of atrial fibrillation (AFIB), characterized by irregular heart rhythms, can potentially save thousands of lives annually [20]. Numerous studies have attempted to address this challenge using various algorithms and methodologies. This paper introduces a novel and robust method that enhances the precision of AFIB detection. Neural Networks (NN) are widely recognized for their ability to identify complex electrocardiogram (ECG) patterns, facilitating the accurate detection of irregular heart rhythms. This study explores multiple conventional machine learning algorithms alongside neural network approaches to develop a robust AFIB detection system. To evaluate the effective- ness and robustness of the proposed method, the MIT BIH arrhythmia database (MITDB) and the Long-term Atrial Fibrillation Database (LTAFDB), both available on the Physionet site. Our approach presents a novel feature engineering technique, employing specific features such as a time series of the differences in successive heart rates (dBPM) rather than traditional inter-beat intervals. The model analyzes inputs labeled into five distinct classes, using only clean intervals identified through a new labeling method for training while treating others as outliers. This strategy ensures a more accurate and reliable AFIB detection process. The best-performing model, a Deep Neural Network (DNN), achieved an F1 score of 95.18% for binary atrial fibrillation classification on a benchmark dataset distinct from the training set. Models trained using our approach have demonstrated superior performance than previously published models.

0.48

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.72
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.20

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.69
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray Angiography

cs.CV ·2026-10-23 ·Haobo Zhu, Mojtaba Lashgari, Jason Chai, Giovanni Luigi De Maria, Vicente Grau +1 more
similarity 0.67
Abstract · 12 pages, 3 figures

Coronary artery disease remains a leading cause of mortality, with stenosis detection from invasive X-ray Coronary Angiography (XCA) critical for diagnosis. Manual interpretation is time-consuming, subjective, and variable, especially under low contrast and vessel overlap. Existing deep learning methods often rely solely on detection or segmentation, limiting performance. We propose a hybrid framework, Fusion-YOLOv11-L, combining a YOLOv11-L detector with a pretrained UNet++ via a channel attention gating module. This enables fusion of semantic and vessel-aware structural features, improving localisation of stenotic regions. The UNet++ is pretrained on ARCADE vessel segmentation dataset to provide anatomically informed representations. Experiments on the relabeled ARCADE (ARCADE*) dataset show improved performance over YOLOv11-L, achieving AP@50 of 0.585 and F1-score of 0.596. Cross-domain evaluation on a dataset from the Oxford Acute Myocardial Infarction (OxAMI) Study reveals performance degradation due to domain shift, mitigated using test-time adaptation and augmentation. Test-time augmentation improves AP@50 from 0.434 to 0.480, indicating better generalisability. These results show that cross-architecture feature fusion and lightweight adaptation improve robustness and generalisability of automated stenosis detection in XCA.

0.27

A Hybrid Predictive Ensemble of Machine Learning and Deep Neural Networks for Early Cardiovascular Disease Risk Assessment

cs.AI cs.LG ·2026-09-04 ·Balaji Venkateswaran
similarity 0.67
Abstract · 14 pages, 7 figures, 2 tables

This study introduces an intelligent framework that integrates machine learning and deep neural network ensemble techniques for early detection and prognosis of cardiovascular diseases. The system utilizes real-time physiological data collected from Internet of Medical Things (IoMT) devices, including ECG sensors, heart rate monitors, and blood pressure trackers. To ensure the accuracy and reliability of input data, preprocessing steps such as noise reduction, normalization, and missing value imputation are employed. The most significant health indicators are identified through effective feature selection methods and then processed using optimized classifiers such as Support Vector Machines (SVM), Random Forests, and eXtreme Gradient Boosting (XGBoost), which are combined in an ensemble architecture to improve diagnostic precision. The framework demonstrates remarkable performance in predicting cardiovascular disease risk, achieving higher accuracy, reduced false positives, and enhanced consistency compared to conventional methods. It is designed on a cloud-based infrastructure that ensures scalability and real-time processing for continuous patient monitoring. Experimental evaluation on real-world cardiovascular datasets confirms the framework's efficiency in early-stage risk assessment and clinical decision support. The results highlight the potential of combining traditional machine learning and deep learning paradigms to achieve proactive healthcare management and improve patient outcomes.

0.10

The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification

eess.IV cs.CV ·2026-08-29 ·Olivier Bernard, William A. Romero R., Cyprien Bouton, Celia Goujat, Hang Jung Ling +22 more
top venue similarity 0.66
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:032

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.

0.55

Enhancing Atrial Fibrillation Detection Through Hyperparameter Optimization

cs.LG ·2026-10-29 ·Sara Gjorgjieva, Ilinka Ivanoska, Marjan Gusev
publishedhot direction similarity 0.66
Abstract · 11 pages, 3 figures, 6 tables. Presented at the ICT Innovation 2025 Conference, Ohrid, North Macedonia. Accepted for publish by Springer in …

This study explores the role of hyperparameter optimization (HPO) in enhancing the detection of Atrial Fibrillation (AF) using both machine learning and deep learning models. We evaluated a range of standard classifiers - Decision Tree, Random Forest, and XGBoost classifiers, alongside deep learning architectures including Recurrent Neural Networks, Deep Neural Networks, and Siamese Neural Networks. To fine-tune these models, we applied four HPO methods: Genetic Algorithm, Hyperband, Optuna, and SMAC3. The experiments were conducted using inter-patient and intra- patient data splits to assess model generalization and robustness in the presence of class imbalance, which is reflective of real-world AF occurrence. Our results, based on PhysioNet electrocardiogram datasets, showed that the Hyperband-optimized XGBoost model outperformed all others, achieving a peak F1 score of 96.95%. These findings highlight the critical role of suitable HPO strategies in enhancing the accuracy and robustness of AF classification outcomes in clinical settings.

0.39

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.66
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.33