CS Paper Radar

Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray Angiography

Haobo Zhu, Mojtaba Lashgari, Jason Chai, Giovanni Luigi De Maria, Vicente Grau, Abhirup Banerjee

cs.CV ·submitted 2026-10-23 14:48 UTC · v2

Abstract

Coronary artery disease remains a leading cause of mortality, with stenosis detection from invasive X-ray Coronary Angiography (XCA) critical for diagnosis. Manual interpretation is time-consuming, subjective, and variable, especially under low contrast and vessel overlap. Existing deep learning methods often rely solely on detection or segmentation, limiting performance. We propose a hybrid framework, Fusion-YOLOv11-L, combining a YOLOv11-L detector with a pretrained UNet++ via a channel attention gating module. This enables fusion of semantic and vessel-aware structural features, improving localisation of stenotic regions. The UNet++ is pretrained on ARCADE vessel segmentation dataset to provide anatomically informed representations. Experiments on the relabeled ARCADE (ARCADE*) dataset show improved performance over YOLOv11-L, achieving AP@50 of 0.585 and F1-score of 0.596. Cross-domain evaluation on a dataset from the Oxford Acute Myocardial Infarction (OxAMI) Study reveals performance degradation due to domain shift, mitigated using test-time adaptation and augmentation. Test-time augmentation improves AP@50 from 0.434 to 0.480, indicating better generalisability. These results show that cross-architecture feature fusion and lightweight adaptation improve robustness and generalisability of automated stenosis detection in XCA.

Comment
12 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

MoE-based Feature Adapter for Prompt-free Binary Coronary Artery Segmentation in X-ray Angiography

cs.CV ·2026-08-25 ·Lin Xi, Yingliang Ma
similarity 0.72
Abstract

Accurate segmentation of coronary arteries in X-ray angiography videos is essential for quantitative coronary analysis and image-guided interventions. However, accurate segmentation remains challenging because coronary vessels are thin and exhibit low contrast, while the presence of catheters, guidewires, and complex anatomical background structures can further interfere with vessel delineation. Existing U-Net- and Transformer-based models provide strong baselines, but their shared feature-adaptation pathways may be insufficient for heterogeneous angiographic appearances. In this paper, we propose a prompt-free mixture-of-experts (MoE) feature adapter for binary coronary artery segmentation. Built upon parameter-efficient Vision Transformer adapters, the proposed method uses multiple lightweight experts with input-dependent top-$k$ routing to adaptively refine vessel-related features while limiting active computational cost. Experiments on MOSXAV and external evaluation on XACV show that the proposed method outperforms representative baselines and improves cross-dataset generalisation. These results suggest that MoE-based adapter learning is effective for robust coronary artery segmentation in X-ray angiography videos.

0.26

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.71
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

CXR-CMFA: A Cross-Modal Feature Aggregation Network for Chest X-Ray Pathology Classification

cs.CV cs.AI ·2026-11-06 ·Talukder Hasnat Zadid, Jahin Sultana, Felipe Bochini Brisola, Kishore Roy, Mysha Rahman +2 more
benchmark similarity 0.70
Abstract

Chest X-ray (CXR) interpretation remains challenging because subtle pathology can be obscured by overlapping anatomy, image-quality variation, and limited visual evidence in isolated radiographs. Although image-only deep learning models provide useful baselines, they discard the complementary diagnostic context available in radiology reports, while large vision-language models can be computationally expensive for practical deployment. This paper presents CXR-CMFA, a lightweight cross-modal feature aggregation network for binary CXR pathology classification. The proposed framework combines a dual-stream visual encoder, using EfficientNet-B0 for global anatomical representation and DenseNet-121 for local pathological detail, with a TF-IDF-MLP report encoder. Two fusion modules integrate these modalities: the Dual-Modal Spatial Attention Module (DMSAM) uses the report embedding to gate global and local visual features, and the Cross-Modal Gated Feature Fusion (CGFF) module learns per-instance weights for visual and textual contributions. Experiments on the MIMIC-CXR benchmark, using the provided train, validation, and test splits, show that CXR-CMFA achieves 93.45% accuracy, 99.88% precision, 91.8% recall, 95.7% F1-score, and 99.19% AUC on the held-out test set. The model produces only four false positives among 984 normal test cases, supporting its suitability for high-specificity screening workflows. An ablation study further demonstrates a 22.47 percentage-point AUC improvement over the global-image-only variant, confirming the value of adaptive cross-modal fusion. These results indicate that compact report-conditioned fusion can provide strong discriminative performance without relying on large pretrained language models.

0.14

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.68
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18

Example-based Robust Abnormality Detection with Minimal Annotations using Exemplar Med-DETR

cs.CV ·2026-08-25 ·Sheethal Bhat, Bogdan Georgescu, Awais Mansoor, Mathias Zinnen, Pranjal Sahu +3 more
similarity 0.68
Abstract

Reducing annotation requirements remains a key challenge in developing robust medical object detectors. To address this, Vision-Language (VL) object detection methods leverage grounding text information to enable powerful zero-shot and few-shot object detectors in the natural image domain [1, 2, 3, 4]. However, transferring these methods to the medical domain is challenging due to the absence of comparable quality and quantity of the grounding data. Regardless, significant contextual and non-imaging information exists in medical images that remains underutilized. Few-shot learning (FSL) techniques partially address this limitation but struggle to general ize to unseen medical findings and require extensive retraining when new findings are introduced [5, 6]. To overcome these challenges, we extend our prior EM-DETR framework [7] and introduce a scalable FS detection approach designed for efficient abnormality detection in Chest X-Ray (CXR) images under minimal supervision. The proposed architecture incorporates exemplar-based feature generation and domain-aware contrastive optimization, enabling effective adaptation to novel disease findings without exhaustive retraining. Our method achieves near state-of-the-art (SOTA) detection performance using less than 10% of the annotated data, demonstrating its potential for practical, annotation-efficient clinical deployment across both proprietary and public CXR datasets.

0.19

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.67
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
similarity 0.67
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.67
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.20