CS Paper Radar

MoE-based Feature Adapter for Prompt-free Binary Coronary Artery Segmentation in X-ray Angiography

Lin Xi, Yingliang Ma

cs.CV ·submitted 2026-08-25 16:24 UTC · v1

Abstract

Accurate segmentation of coronary arteries in X-ray angiography videos is essential for quantitative coronary analysis and image-guided interventions. However, accurate segmentation remains challenging because coronary vessels are thin and exhibit low contrast, while the presence of catheters, guidewires, and complex anatomical background structures can further interfere with vessel delineation. Existing U-Net- and Transformer-based models provide strong baselines, but their shared feature-adaptation pathways may be insufficient for heterogeneous angiographic appearances. In this paper, we propose a prompt-free mixture-of-experts (MoE) feature adapter for binary coronary artery segmentation. Built upon parameter-efficient Vision Transformer adapters, the proposed method uses multiple lightweight experts with input-dependent top-$k$ routing to adaptively refine vessel-related features while limiting active computational cost. Experiments on MOSXAV and external evaluation on XACV show that the proposed method outperforms representative baselines and improves cross-dataset generalisation. These results suggest that MoE-based adapter learning is effective for robust coronary artery segmentation in X-ray angiography videos.

Closest papers

Nearest neighbours by meaning across the whole index.

Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray Angiography

cs.CV ·2026-10-23 ·Haobo Zhu, Mojtaba Lashgari, Jason Chai, Giovanni Luigi De Maria, Vicente Grau +1 more
similarity 0.72
Abstract · 12 pages, 3 figures

Coronary artery disease remains a leading cause of mortality, with stenosis detection from invasive X-ray Coronary Angiography (XCA) critical for diagnosis. Manual interpretation is time-consuming, subjective, and variable, especially under low contrast and vessel overlap. Existing deep learning methods often rely solely on detection or segmentation, limiting performance. We propose a hybrid framework, Fusion-YOLOv11-L, combining a YOLOv11-L detector with a pretrained UNet++ via a channel attention gating module. This enables fusion of semantic and vessel-aware structural features, improving localisation of stenotic regions. The UNet++ is pretrained on ARCADE vessel segmentation dataset to provide anatomically informed representations. Experiments on the relabeled ARCADE (ARCADE*) dataset show improved performance over YOLOv11-L, achieving AP@50 of 0.585 and F1-score of 0.596. Cross-domain evaluation on a dataset from the Oxford Acute Myocardial Infarction (OxAMI) Study reveals performance degradation due to domain shift, mitigated using test-time adaptation and augmentation. Test-time augmentation improves AP@50 from 0.434 to 0.480, indicating better generalisability. These results show that cross-architecture feature fusion and lightweight adaptation improve robustness and generalisability of automated stenosis detection in XCA.

0.27

UI-VISA: U-Net Initialized Vascular Image Segmentation Architecture

cs.CV ·2026-09-01 ·Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
similarity 0.69
Abstract · 9 pages, 6 figures

Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branching nature of blood vessels. Pixel-wise deep learning approaches such as U-Net achieve strong general-purpose segmentation performance but often produce fragmented or discontinuous predictions in fine vascular regions, since they do not explicitly enforce structural connectivity. Region growing algorithms preserve spatial context and topological continuity, but are highly sensitive to seed point initialization and can be computationally expensive. We propose UI-VISA (U-Net Initialized Vascular Image Segmentation Architecture), a hybrid pipeline that combines the complementary strengths of both approaches. UI-VISA uses U-Net's foreground predictions as informed seed points for a CNN-guided region growing algorithm, which then iteratively refines the segmentation by enforcing local connectivity and recovering fine vessel details that U-Net alone tends to miss or over-predict. We evaluate UI-VISA against standalone U-Net and a prior region-growing-based method (VISA) using 5-fold cross-validation on 26 DSA images. UI-VISA achieves the highest mean Dice and clDice scores across folds, and a paired Wilcoxon signed-rank test shows the improvement in clDice is statistically significant ($p=0.023$), consistent with the method's design goal of preserving vascular connectivity, while the improvement in Dice does not reach significance ($p=0.104$).

0.22

BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis

cs.CV ·2026-09-14 ·Wanxian Li, Jiaqian Qin, Qingyi Xian, Yazhi Li, Song Chen +2 more
similarity 0.67
Abstract · 29 pages, 9 figures, including Supplementary Material

Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease.

0.21

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.67
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.65
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Dual-Part Multi-Lateral Branched Network for Multi-Class Segmentation in Cardiovascular Catheterization Angiograms

cs.CV cs.AIcs.RO ·2026-09-04 ·Olatunji Omisore, Ahmed Elazab, Ali Shahidinejad, Fariza Sabrina
hot direction similarity 0.65
Abstract

Catheterisation image processing requires segmentation models that are fast, accurate and explainable. While most of the existing studies usually focus on binary segmentation, there is a recent demand for simultaneous segmentation of multiple structures found in catheterization scenes. In this study, a dual-part MLBNet architecture is designed with multi-lateral encoder blocks and multi-head decoder branches for class-aware segmentation in cardiovascular catheterization scenes. Lateral branches in the encoder enable repeated feature extraction to learn diverse shared representations, while multiple decoder heads are used to introduce class-skewed branches that specialize in different structural properties in catheterization scenes. To analyze the performances of the dual-part MLBNet architecture, several multi-class segmentation angiogram data obtained during cardiovascular catheterization in phantom models, synthetic human-simulated aorta, and animal model are used for model training and evaluation. Results obtained showed the dual-part models could effectively separate guidewire, catheter, vessels and background pixels to their classes of memberships with high probability. The results demonstrate that all models were able to distinguish the dominant background class from foreground structures with high overall accuracy.

0.33

GazeRefine: Expert Gaze as a Test-Time Prompt for Training-Free Medical Image Segmentation

eess.IV cs.AIcs.CVcs.HC+1 ·2026-09-01 ·Mohammed Oussama Benyahia, Marouane Tliba, Mohamed Amine Kerkouri, Taifour Yousra, Bin Wang +8 more
publishedcode/data similarity 0.64
Abstract · 9 pages, 5 figures. Accepted at MICCAI Workshop 2026

Medical image segmentation remains difficult to scale because high-performing methods typically rely on dense expert annotations and task-specific training. We introduce GazeRefine, a training-free framework that uses gaze as an inference-time prompt for zero-shot medical image segmentation. Sparse, duration-weighted fixations are converted into foreground and background priors that initialize semantic prototypes in frozen DINOv3 feature space. These prototypes are iteratively refined through foreground-background discrimination, feature-space affinity propagation, and anchoring to the initial gaze guidance, allowing segmentation to extend beyond directly fixated regions while limiting semantic drift. GazeRefine requires no segmentation masks, fine-tuning, adapters, prompt encoders, or gradient updates. We evaluate the method on gaze-annotated polyp segmentation and prostate MRI segmentation. The results show strong performance on colonoscopy images and competitive performance on prostate MRI, supporting gaze-guided prototype refinement as a promising approach for segmentation-label-efficient, human-in-the-loop medical image segmentation. Our tools and code can be found in the following repository: https://github.com/MohammedOussamaBEN/GazeRefine.git

0.72

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.64
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32