CS Paper Radar

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar

cs.CV cs.AI ·submitted 2026-10-29 15:46 UTC · v1

Abstract

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

Comment
7 pages, 2 figures, 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

ConPro: Contrast Projection Pretraining for Label-Efficient Vessel Segmentation in DSA Sequences

cs.CV ·2026-09-24 ·Xinge Guo, Yuanhao Wang, Liqi Shu, Yang Liu, Min Xu
similarity 0.75
Abstract · 5 pages, 4 figures, 2 tables. Submitted to IEEE ICASSP 2027

Dense vessel annotation in digital subtraction angiography (DSA) is labor-intensive, yet every unlabeled sequence records how contrast passes through the vessels. Semi-supervised methods take their targets from the current model, and generic self-supervised pretexts reconstruct static appearance, so this signal goes unused. We propose ConPro, a self-supervised pretraining scheme whose target is a contrast projection, the normalized drop of every pixel below its temporal median over the sequence. On DIAS and DSCA, with 10%, 20% and 50% of the training cases labeled, ConPro improves on training from scratch at every label fraction and is the best of the compared methods on DSCA at 20% and 50% labels. Controlled comparisons show that the gain comes from the target. A temporal-median target with the same input, loss and budget stays at scratch level, and using the projection directly instead of learning it, as an input channel or a pseudo-label, helps little or hurts. ConPro provides pretrained weights without changing the segmentation architecture, so it combines with semi-supervised training, and UniMatch, the strongest baseline, gains 0.5 to 2.0 Dice and 0.9 to 2.3 clDice at every label fraction when started from ConPro weights, reaching 75.4 Dice on DIAS and 81.3 on DSCA.

0.31

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

cs.CV eess.IV ·2026-08-31 ·Jiacheng Wang, Ivana Isgum, Ipek Oguz
benchmarkcode/data similarity 0.71
Abstract · 12 pages, 4 figures

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

0.38

Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray Angiography

cs.CV ·2026-10-23 ·Haobo Zhu, Mojtaba Lashgari, Jason Chai, Giovanni Luigi De Maria, Vicente Grau +1 more
similarity 0.68
Abstract · 12 pages, 3 figures

Coronary artery disease remains a leading cause of mortality, with stenosis detection from invasive X-ray Coronary Angiography (XCA) critical for diagnosis. Manual interpretation is time-consuming, subjective, and variable, especially under low contrast and vessel overlap. Existing deep learning methods often rely solely on detection or segmentation, limiting performance. We propose a hybrid framework, Fusion-YOLOv11-L, combining a YOLOv11-L detector with a pretrained UNet++ via a channel attention gating module. This enables fusion of semantic and vessel-aware structural features, improving localisation of stenotic regions. The UNet++ is pretrained on ARCADE vessel segmentation dataset to provide anatomically informed representations. Experiments on the relabeled ARCADE (ARCADE*) dataset show improved performance over YOLOv11-L, achieving AP@50 of 0.585 and F1-score of 0.596. Cross-domain evaluation on a dataset from the Oxford Acute Myocardial Infarction (OxAMI) Study reveals performance degradation due to domain shift, mitigated using test-time adaptation and augmentation. Test-time augmentation improves AP@50 from 0.434 to 0.480, indicating better generalisability. These results show that cross-architecture feature fusion and lightweight adaptation improve robustness and generalisability of automated stenosis detection in XCA.

0.27

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.68
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis

cs.CV ·2026-09-14 ·Wanxian Li, Jiaqian Qin, Qingyi Xian, Yazhi Li, Song Chen +2 more
similarity 0.65
Abstract · 29 pages, 9 figures, including Supplementary Material

Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease.

0.21

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.64
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.64
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

Extending the Horizon of Early Diagnosis: Lung Cancer Prediction with Vision Transformers

cs.CV ·2026-08-21 ·Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson +9 more
similarity 0.63
Abstract

Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage malignancies can be subtle on chest X-rays, creating challenges for radiologists. This study evaluates Vision Transformers (ViTs) for predicting lung cancer one to two years before clinical diagnosis. We analyzed 259,361 chest X-rays from 91,020 imaging studies at the Jamaica Plains VA Hospital in Boston, MA. The dataset showed extreme class imbalance, approximately 1:150 cancer to non-cancer, which was addressed using hybrid under- and over-sampling and class-weighted loss optimization. Three ViT configurations were evaluated: a model trained from scratch, an ImageNet-pretrained model, and a Corona-pretrained model fine-tuned on the lung cancer dataset. Transfer learning improved performance, with pretrained models exceeding the scratch baseline by 6-10 percentage points in AUC and about 10-12 percent in balanced accuracy. ImageNet-pretrained models showed the most stable overall performance, while Corona-pretrained models achieved higher sensitivity in some settings but greater variability. Moderate resampling ratios, including 1:1 undersampling and 1.5:2 oversampling, provided favorable trade-offs between sensitivity, precision, and computational efficiency, reducing runtime by up to 70 percent without major performance loss. These findings demonstrate the potential of ViTs for early lung cancer risk prediction from routine chest X-rays. Although performance remains below clinical deployment thresholds, the results support further development of ViT-based triage systems to flag high-risk patients for earlier evaluation.

0.09