CS Paper Radar

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

Jiacheng Wang, Ivana Isgum, Ipek Oguz

cs.CV eess.IV ·submitted 2026-08-31 16:47 UTC · v1
benchmarkcode/data

Abstract

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

Comment
12 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.75
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.74
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.71
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18

SymmAdapt: Symmetrical Flow Matching for Source-Free Domain Adaptation in Medical Image Segmentation

cs.CV ·2026-08-23 ·Tal Grossman, Noa Cahan, Hayit Greenspan
published similarity 0.71
Abstract · Accepted at SASHIMI 2026, held in conjunction with MICCAI 2026. To appear in the Springer LNCS proceedings of the MICCAI 2026 Satellite Even…

Domain shift across imaging modalities and acquisition sites remains a significant barrier to the clinical deployment of segmentation models. Source-free unsupervised domain adaptation (SFUDA) addresses this by adapting a pretrained model to an unlabeled target domain without requiring access to sensitive source data. We introduce a novel SFUDA framework built on Symmetrical Flow Matching, a unified generative model that segments an input image and synthesizes a source-like image from a mask within the same learned flow. By initializing inference from a domain-agnostic Gaussian origin, the model preserves structural consistency across domains and grounds predictions in learned anatomy rather than shifted texture statistics. Our pipeline leverages this symmetry to generate reliable pseudo-labels and corresponding source-like synthetic images from unlabeled target data, creating a generative replay buffer that anchors source knowledge during a generative self-training stage that fine-tunes on a joint set of real target and synthetic source-like images. We evaluate on abdominal multi-organ and cardiac segmentation, covering cross-modality MRI<->CT shifts, and multi-site prostate segmentation. Our approach outperforms SFUDA baselines and is competitive with conventional UDA methods.

0.25

Label-Preserving Fourier Domain Adaptation with Generative-AI and Real Style Donors for 3D Mitral Valve Segmentation

eess.IV cs.CV ·2026-11-03 ·Javeria Javed, Ahmed Salim, Muhammad Mahboob Ur Rahman
similarity 0.69
Abstract · 7 pages, 1 figure, 3 tables, submitted to IEEE for possible publication

Accurate segmentation of the mitral valve from three-dimensional transesophageal echocardiography (3D TEE) is severely restricted by the scarcity of publicly available expert- annotated volumetric datasets. To address this critical limitation, we investigated Fourier Domain Adaptation (FDA), utilizing general-purpose generative-AI images (from platforms like Chat- GPT, Google Gemini, and Microsoft MAI) as annotation-free style donors for 3D mitral valve segmentation. We employed a DeepMitral residual U-Net model on the public MVSeg2023 dataset, comparing six conditions over three runs: real-only training, traditional augmentation, FDA with each generative source, and a non-AI FDA control using real-image style donors, plus an optimization-matched real-only control and a \b{eta} sensitivity analysis. Case-level paired testing showed that FDA with these generative sources led to significant reductions in boundary- and surface-related errors across all three donor conditions relative to the primary real-only baseline. However, the impact on the core segmentation metric, Generalized Dice Score (GDS), proved generator-dependent. ChatGPT-FDA showed a significant GDS advantage over the optimization-matched control but not over the primary baseline, and Gemini-FDA showed no significant GDS difference. Notably, only MAI-FDA provided a statistically robust and significant increase in GDS compared to the primary baseline. The \b{eta} sensitivity was not robust across training runs. These findings confirm that FDA remains an important augmentation mechanism. While generative-AI images offer a practical means of acquiring style diversity without new annotations, the non-AI control performed comparably to ChatGPT-FDA, so we do not conclude that this approach is superior to training with real-image donors.

0.27

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.68
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

MCSeg: Pre-training and Fine-tuning Volumetric Pyramid Transformer for Multi-modal Cardiac Image Segmentation

cs.CV ·2026-08-31 ·Zhiyu Ye, Hairong Zheng, Tong Zhang
publishedcode/data similarity 0.67
Abstract · Accepted for publication in IEEE Journal of Biomedical and Health Informatics

Automatic cardiac image segmentation is pivotal for diagnosing and treating cardiac diseases. In this work, we introduce MCSeg, a volumetric transformer-based network tailored for multi-modal cardiac segmentation. To overcome the architectural mismatch inherent in existing hybrid networks, we propose a novel Scaling Feature Pyramid (SFP). Unlike conventional skip connections, the SFP effectively bridges the single-scale 3D Vision Transformer (ViT) encoder and the multi-scale CNN decoder by transforming the ViT's output into a hierarchical feature pyramid, ensuring that global contextual information is effectively leveraged. For the training paradigm, the ViT encoder first undergoes self-supervised pre-training via masked image modeling. Subsequently, the network is fine-tuned on downstream tasks, during which a regional mutual information (RMI) loss is integrated to improve boundary segmentation accuracy. In experiments, MCSeg consistently outperforms eleven SOTA methods on CT dataset ImageCHD, multi-modal dataset MM-WHS, MRI dataset HVSMR-2.0 and MSD Heart, highlighting the effectiveness of our MCSeg for multi-modal cardiac segmentation tasks. Furthermore, MCSeg's superior performance in few-shot experiment showcases its significant potential in adapting to limited data scenarios. Codes and pre-trained ViT-B weights are open-sourced at https://openi.pcl.ac.cn/OpenMedIA/MCSeg

0.40

The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification

eess.IV cs.CV ·2026-08-29 ·Olivier Bernard, William A. Romero R., Cyprien Bouton, Celia Goujat, Hang Jung Ling +22 more
top venue similarity 0.67
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:032

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.

0.55