CS Paper Radar

Improving Cross-Site Whole-Heart Segmentation

Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao, Xin Wang, Shu Hu

eess.IV cs.CV ·submitted 2026-08-25 20:03 UTC · v1
publishedcode/data

Abstract

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

Comment
12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Closest papers

Nearest neighbours by meaning across the whole index.

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

cs.CV eess.IV ·2026-08-31 ·Jiacheng Wang, Ivana Isgum, Ipek Oguz
benchmarkcode/data similarity 0.75
Abstract · 12 pages, 4 figures

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

0.38

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.74
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation

cs.CV physics.med-ph ·2026-09-11 ·Lila Cunge
similarity 0.71
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.

0.12

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.71
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

CMRVision: A Foundation Model for Cardiac MR Image Analysis

cs.CV ·2026-09-01 ·Athira J. Jacob, Puneet Sharma, Daniel Rueckert
publishedbenchmark similarity 0.70
Abstract · Accepted at MedAGI 2026 (peer-reviewed workshop at MICCAI 2026)

Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.

0.28

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.70
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

CIRSeg: Coarse-to-Fine Intensity-Robust Liver Segmentation with Source-Free Continual Test-Time Adaptation

cs.CV ·2026-10-07 ·Ruoshi Xu, Mingqi Gao, Shengda Luo, Jingkun Chen
publishedcode/data similarity 0.70
Abstract · Accepted at the CARE 2026 Workshop at MICCAI 2026

Reliable liver segmentation in contrast-enhanced MRI is essential for quantitative hepatic assessment, treatment planning, and longitudinal disease monitoring. However, limited annotated data and scanner- or vendor-dependent intensity variations can cause overfitting and poor generalization to unseen acquisition domains. Moreover, simultaneously achieving robust global localization and precise boundary delineation remains challenging, while predictions may contain isolated false-positive regions outside the main liver component. To address these challenges, we propose CIRSeg, a coarse-to-fine, intensity-robust liver segmentation framework based on nnU-Netv2. CIRSeg combines 3D CutMix with stochastic intensity transfer using either Nyul augmentation or histogram matching to improve robustness to heterogeneous MRI intensities. Its cascaded architecture decouples low-resolution anatomical localization from full-resolution boundary refinement. At inference, source-free test-time adaptation based on confidence-filtered predictions and probability-prior regularization further improves robustness to out-of-distribution inputs. As a final deterministic post-processing step, largest connected component filtering removes isolated false-positive regions. On the CARE 2026 test set, CIRSeg achieves Dice scores of 97.13\% and 97.93\% on the in-domain and unseen-domain subsets, with corresponding HD95 values of 20.18 mm and 11.30 mm, respectively. These results demonstrate consistently accurate segmentation across both in-domain and unseen acquisition settings. The code is available at https://github.com/jingkunchen/MICCAI_CARE_2026

0.28

CNVAE: Anatomically Correct Segmentation via Conditional Generative Modeling

eess.IV ·2026-11-04 ·Freddy Jiang, Loic Le Folgoc, Elsa Angelini
similarity 0.70
Abstract

Supervised deep learning segmentation models, although unparalleled in performance, are not immune to anatomical mistakes. We develop a segmentation-by-generation paradigm extending the Nouveau VAE (NVAE) generative framework for anatomically correct cardiac segmentation. In particular, we propose a novel conditional NVAE model (CNVAE) for conditional shape generation, and explore its capabilities for image segmentation in two scenarios: (1) direct image-to-mask CNVAE for one-step segmentation; (2) mask-to-mask CNVAE for refinement of segmentation masks produced by third-party segmentation models. Both models are lightweight and return consistently anatomically valid segmentation masks (> 98% success rate, an improvement of 15% above state-of-the-art segmentation models) on the cardiac segmentation/editing tasks of interest, without loss of accuracy in segmented contours.

0.25