CS Paper Radar

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais

cs.CV cs.LGq-bio.QM ·submitted 2026-08-20 12:35 UTC · v1
published

Abstract

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

Comment
International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Closest papers

Nearest neighbours by meaning across the whole index.

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.76
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.75
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.74
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

UI-VISA: U-Net Initialized Vascular Image Segmentation Architecture

cs.CV ·2026-09-01 ·Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
similarity 0.74
Abstract · 9 pages, 6 figures

Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branching nature of blood vessels. Pixel-wise deep learning approaches such as U-Net achieve strong general-purpose segmentation performance but often produce fragmented or discontinuous predictions in fine vascular regions, since they do not explicitly enforce structural connectivity. Region growing algorithms preserve spatial context and topological continuity, but are highly sensitive to seed point initialization and can be computationally expensive. We propose UI-VISA (U-Net Initialized Vascular Image Segmentation Architecture), a hybrid pipeline that combines the complementary strengths of both approaches. UI-VISA uses U-Net's foreground predictions as informed seed points for a CNN-guided region growing algorithm, which then iteratively refines the segmentation by enforcing local connectivity and recovering fine vessel details that U-Net alone tends to miss or over-predict. We evaluate UI-VISA against standalone U-Net and a prior region-growing-based method (VISA) using 5-fold cross-validation on 26 DSA images. UI-VISA achieves the highest mean Dice and clDice scores across folds, and a paired Wilcoxon signed-rank test shows the improvement in clDice is statistically significant ($p=0.023$), consistent with the method's design goal of preserving vascular connectivity, while the improvement in Dice does not reach significance ($p=0.104$).

0.22

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.72
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.71
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.71
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

Unsupervised Adaptation of 3D CT Foundation Models for 3D CBCT Segmentation

cs.CV ·2026-08-27 ·Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon, Pietro Gori
publishedcode/data similarity 0.71
Abstract · Accepted at the EMA4MICCAI workshop at MICCAI 2026. 11 pages, 4 figures, 1 table. Code, trained models, weights, and liver annotations are a…

Accurate 3D segmentation of cone-beam CT (CBCT) is critical for interventional and radiation therapy applications, yet it remains limited by two compounding challenges: the scarcity of annotated CBCT data and the large domain shift from diagnostic CT. Interventional CBCT exhibits fundamental modality differences from conventional CT, driven by acquisition and physics effects as well as contrast-specific vascular content, thereby limiting effective cross-modality model transfer. We propose a novel unsupervised domain adaptation (UDA) framework based on redundancy-reducing feature alignment, enabling 3D CBCT segmentation with no target-domain annotations or inference-time adaptation. Our framework is architecture-agnostic, seamlessly adapting both CNN-based and ViT-based foundation models. We evaluate our method on two challenging CT-CBCT liver segmentation benchmarks: one for interventional vascular procedures and one for radiation therapy, demonstrating that even large-scale pretrained segmentation networks require explicit feature-space bridging to generalize across acquisition modalities, and that our approach consistently outperforms existing pretrained foundation model and UDA strategies. To support reproducibility and benchmarking, we release the liver segmentations for a public CBCT dataset, along with the code, trained models, and weights.

0.41