CS Paper Radar

Unsupervised Adaptation of 3D CT Foundation Models for 3D CBCT Segmentation

Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon, Pietro Gori

cs.CV ·submitted 2026-08-27 14:33 UTC · v1
publishedcode/data

Abstract

Accurate 3D segmentation of cone-beam CT (CBCT) is critical for interventional and radiation therapy applications, yet it remains limited by two compounding challenges: the scarcity of annotated CBCT data and the large domain shift from diagnostic CT. Interventional CBCT exhibits fundamental modality differences from conventional CT, driven by acquisition and physics effects as well as contrast-specific vascular content, thereby limiting effective cross-modality model transfer. We propose a novel unsupervised domain adaptation (UDA) framework based on redundancy-reducing feature alignment, enabling 3D CBCT segmentation with no target-domain annotations or inference-time adaptation. Our framework is architecture-agnostic, seamlessly adapting both CNN-based and ViT-based foundation models. We evaluate our method on two challenging CT-CBCT liver segmentation benchmarks: one for interventional vascular procedures and one for radiation therapy, demonstrating that even large-scale pretrained segmentation networks require explicit feature-space bridging to generalize across acquisition modalities, and that our approach consistently outperforms existing pretrained foundation model and UDA strategies. To support reproducibility and benchmarking, we release the liver segmentations for a public CBCT dataset, along with the code, trained models, and weights.

Comment
Accepted at the EMA4MICCAI workshop at MICCAI 2026. 11 pages, 4 figures, 1 table. Code, trained models, weights, and liver annotations are available at https://github.com/mirabll/FARR3D/

Closest papers

Nearest neighbours by meaning across the whole index.

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.71
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

FleXray: Universal Clinical X-ray Segmentation

cs.CV cs.AI ·2026-09-22 ·Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
similarity 0.71
Abstract · 35 pages, 12 figures, 10 tables. Code, models, data, and a browser-based demo at https://flexray.csail.mit.edu

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

0.27

CIRSeg: Coarse-to-Fine Intensity-Robust Liver Segmentation with Source-Free Continual Test-Time Adaptation

cs.CV ·2026-10-07 ·Ruoshi Xu, Mingqi Gao, Shengda Luo, Jingkun Chen
publishedcode/data similarity 0.70
Abstract · Accepted at the CARE 2026 Workshop at MICCAI 2026

Reliable liver segmentation in contrast-enhanced MRI is essential for quantitative hepatic assessment, treatment planning, and longitudinal disease monitoring. However, limited annotated data and scanner- or vendor-dependent intensity variations can cause overfitting and poor generalization to unseen acquisition domains. Moreover, simultaneously achieving robust global localization and precise boundary delineation remains challenging, while predictions may contain isolated false-positive regions outside the main liver component. To address these challenges, we propose CIRSeg, a coarse-to-fine, intensity-robust liver segmentation framework based on nnU-Netv2. CIRSeg combines 3D CutMix with stochastic intensity transfer using either Nyul augmentation or histogram matching to improve robustness to heterogeneous MRI intensities. Its cascaded architecture decouples low-resolution anatomical localization from full-resolution boundary refinement. At inference, source-free test-time adaptation based on confidence-filtered predictions and probability-prior regularization further improves robustness to out-of-distribution inputs. As a final deterministic post-processing step, largest connected component filtering removes isolated false-positive regions. On the CARE 2026 test set, CIRSeg achieves Dice scores of 97.13\% and 97.93\% on the in-domain and unseen-domain subsets, with corresponding HD95 values of 20.18 mm and 11.30 mm, respectively. These results demonstrate consistently accurate segmentation across both in-domain and unseen acquisition settings. The code is available at https://github.com/jingkunchen/MICCAI_CARE_2026

0.28

nnFoundation: 3D Foundation Models for Radiology

cs.CV eess.IV ·2026-09-22 ·Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp +78 more
highly cited similarity 0.70
Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

0.42

Optimal Transport Metric Learning for Feature Alignment in Partially Supervised Segmentation

eess.IV cs.AI ·2026-09-15 ·Dakini Mallam Garba, Salim Abdou Daoura
similarity 0.70
Abstract

Multi-organ segmentation is often challenged by partially annotated datasets and domain shifts across different imaging sources. To address these limitations, we propose a two-stage learning framework that efficiently leverages partial supervision. In the first stage, the model learns from available annotations to produce accurate segmentations of annotated organs, establishing robust feature representations. In the second stage, we introduce learnable organ prototypes and a Sinkhorn-triplet loss to enforce organ-wise feature consistency across datasets. This encourages latent embeddings of the same organ to remain close, while increasing separation between different organs, even when annotations are missing. Our approach achieves performance comparable to state-of-the-art methods on the BTCV dataset, while remaining computationally efficient. By explicitly aligning feature distributions rather than relying solely on pseudo-labels, the framework effectively mitigates domain shift, making it particularly suitable for medical image segmentation tasks with limited annotation resources.

0.06

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.69
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

cs.CV ·2026-11-17 ·Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel +1 more
publishedcode/data similarity 0.69
Abstract · Accepted at WACV 2027. Code: https://github.com/StanfordMIMI/data-curation-3d-medical-vlm

Training 3D vision-language models (VLMs) on large medical imaging datasets collected across institutions is constrained by data quality. Vast, uncurated pools of image-report pairs are characterized by redundancy, class imbalance, and cross-institutional heterogeneity. We address this challenge of data curation for improving 3D VLM pretraining by proposing an offline, training-free, reference-guided data curation recipe. Our approach leverages a small, high-quality reference set to independently extract quality signals for each modality of a large, uncurated pool and merges them through a rank-aggregation step into a single ranking that guides sample selection. We validate this method on datasets comprising 35k 3D abdominal CT volume-report pairs from two institutions and 58k 2D chest X-ray image-report pairs. On 3D CT, using our reference-guided data curation strategy, our curated model matches the zero-shot disease classification performance of a state-of-the-art baseline (Merlin) while using $3.3\times$ less training data and a reference set of 5k samples. On 2D chest X-rays, our method yields a curated model that matches or exceeds the zero-shot disease classification performance of a model trained on the full pool while using up to $10\times$ less training data and a reference set of only 74 samples. Ablations show that the selection is stable under resampling of the reference, that smaller reference sets still outperform random sampling, and that label rebalancing does not improve performance. To support reproducibility, we release our code.

0.50

Foundation Model-Enabled Efficient Data Sampling (FEEDS): A label-efficient training strategy for pan-cancer, multi-tracer PET/CT datasets

cs.CV ·2026-08-11 ·Biratal Raj Wagle, Bashirul Azam Biswas, Grant Chau, Matthew E. Maeder, Muhammad Azeem Arshad +3 more
code/data similarity 0.68
Abstract · Code is publicly available on https://github.com/Image-and-Multimodal-Data-Analytics/FEEDS

Automated lesion segmentation in whole-body PET/CT imaging can assist clinicians with cancer detection, staging, and treatment planning across radiotracers and cancer types. However, training lesion segmentation models that capture variations in lesion size, distribution, and appearance requires large annotated datasets, whose creation is both time- and expertise-intensive. As a result, models trained on limited labeled PET/CT data often lack the accuracy and generalizability needed for clinical use. We present FEEDS (Foundation model-Enabled Efficient Data Sampling), a label- and compute-efficient learning strategy that uses vision foundation model embeddings to select the most informative and diverse unlabeled cases for expert annotation. Unlike unsupervised, semi-supervised, and active learning approaches, FEEDS is a one-step training paradigm requiring only a limited, representative training set, making it label- and compute-efficient. We train and validate FEEDS using the AutoPET-III dataset. We test its accuracy and generalizability on three held-out sets: AutoPET-III, DeepPSMA, and an internal Dartmouth-Hitchcock Medical Center dataset. We evaluate clinical utility at the voxel, lesion, and anatomic region level to assess performance in high-risk areas and treatment planning utility. FEEDS outperforms random-sampling-based labeling, pseudolabel-based semi-supervised learning, and training with limited labeled data alone. It generalizes across all three test sets, FDG and PSMA tracers, and multiple diseases, matching fully-labeled (100\%) training performance with 70\% less annotation burden. FEEDS addresses the challenge of label scarcity in an automatic lesion segmentation framework by providing a practical approach for constructing representative and diverse annotation queues from large, unannotated clinical repositories.

0.59