CS Paper Radar

nnFoundation: 3D Foundation Models for Radiology

Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp, Maximilian Rokuss, Elisa Stegmeier, Philipp Schader, Dasha Trofimova, Raphael Stock, Kim-Celine Kahl, Stephen Schaumann, Selen Erkan, David Zimmerer, Stefan Denner, Moritz Langenberg, Sebastian Ziegler, Katharina Eckstein, Maximilian Fischer, Jonathan Suprijadi, Bálint Kovács, Benjamin Hamm, Anand Deshpande, Dimitrios Bounias, Nico Disch, Shuhan Xiao, Jessica Kächele, Jan Sellner, Rajesh Baidya, Jeremias Traub, Lars Krämer, Maximilian Zenk, Tim Rädsch, Stefan Dvoretskii, Robin Peretzke, Jonathan Deissler, Alexandra Ertl, Partha Ghosh, Kris Dreher, Stefan Dinkelacker, Annika Reinke, Evangelia Christodoulou, Numan Saeed, Yoland Savriama, Santiago Estrada, David Kügler, Laura Alexandra Daza Barragan, Cristina Isabel Gonzalez Osorio, Jan Peeken, Michael Baumgartner, Marvin Teichmann, Guillaume Chabin, Matthias Kirchler, Valentin Koch, for the ALFA study, Markus Hohenhaus, Dimitri Koslov, Nina Decker, Mohammad Yaqub, Arnd Heuser, Martin Reuter, Julia A. Schnabel, Tobias Heimann, Florin Ghesu, Paul Brachmann, Claus P. Heußel, Alexander Radbruch, Gianluca Brugnara, Aditya Rastogi, Martha Foltyn-Dumitru, Heinz-Peter Schlemmer, Ignaz Reicht, Julius C. Holzschuh, Michael Bach, Bram Stieltjes, Kai Schlamp, Lena Maier-Hein, Marco Nolden, Ralf Floca, Paul F. Jäger, Philipp Vollmuth, Fabian Isensee, Klaus H. Maier-Hein

cs.CV eess.IV ·submitted 2026-09-22 18:18 UTC · v1
highly cited

Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

Closest papers

Nearest neighbours by meaning across the whole index.

VoxForge: A Unified Foundation Model for Dense 3D Features Across MRI, CT and PET

cs.CV cs.LG ·2026-11-19 ·Rushil Anirudh, Jayaraman J. Thiagarajan
similarity 0.75
Abstract · 34 pages (8-page main paper, references, and 23-page supplementary material), 7 figures. Rushil Anirudh and Jayaraman J. Thiagarajan contrib…

A unified 3D medical foundation model promises reusable, frozen features that serve a wide variety of tasks such as segmentation, classification and registration on MRI, CT and PET as well as specialist models do. Generalist models still need separate backbones for localized and global tasks, specialist models are confined to a single modality, with the concern that spanning modalities under-emphasizes fine anatomy, and both typically rely on end-to-end fine-tuning to be competitive. We present VoxForge, a single encoder that integrates recent advances in 3D architecture, self-distillation and cross-modal curricula to learn transferable features from permissively licensed MRI and CT volumes. We evaluate it strictly frozen, the test a reusable foundation model must pass, against state-of-the-art generalist and specialist models on segmentation, classification and registration across MRI and CT, and on PET, which it never sees. VoxForge has the best or tied-best average rank in every task group, serves localized and global tasks across modalities at the level of state-of-the-art specialists, and is extremely label-efficient, matching top-performing models on TotalSegmentator CT with a tenth of the labels.

0.17

DINOv2 for PET: A Pre-Training Domain Benchmark Across Classification, Segmentation, and Prognosis

cs.CV ·2026-10-29 ·Roxanne De Maeyer, Yannick Brackenier, Vicky De Ridder, Simon DeKeyser, Maarten Larmuseau +1 more
publishedbenchmarkcode/data similarity 0.73
Abstract · 8 pages + references, MICCAI 2026, CaPTion workshop

DINO (self-DIstillation with NO labels) has become a stan- dard for self-supervised pre-training, producing features that generalise across datasets and downstream tasks. In medical imaging it has been adopted mainly for radiology (X-ray, CT and MRI), where even natural- image DINO features transfer well. In the literature, these features have been reported to transfer worse to functional imaging such as PET. Yet PET-specific DINO models have barely been introduced, and even less validated across multiple tasks and datasets. We present PET-DINOv2-2D, the first DINOv2 model pre-trained on 2D PET, and benchmark it against open-source encoders: the origi- nal DINOv2 (pre-trained on the LVD-142M natural-image dataset) and OmniRad (pre-trained on CT, MRI and ultrasound). Using the same lightweight heads for every backbone, and despite far less pre-training data, PET-DINOv2-2D matches or outperforms both on three down- stream PET tasks: normal/abnormal classification, lesion segmentation and recurrence-free survival prognosis. Its advantage is largest when few labels are available, suggesting that PET pre-training gives more transferable, label-efficient features. Code is made available at https://github.com/nuclivision/pet-dinov2-2d/.

0.42

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-11-17 ·Evgeny Alves Limarenko
similarity 0.71
Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

0.18

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

eess.IV cs.CV ·2026-10-16 ·Shaojun Li, Xiaoyu Deng, Ikuo Keshi
similarity 0.70
Abstract · 21 pages, 7 figures. Supplementary material included. Under review at Biomedical Signal Processing and Control

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

0.17

Comparative Study of Anatomical and Learned Features in AI Models for Structural Brain MRI

cs.CV cs.AI ·2026-09-06 ·Boyang Yu, Miquel Lopez Escoriza, Long Chen, Arjun V. Masurkar, Narges Razavian +1 more
published similarity 0.70
Abstract

In this work, we comprehensively evaluate three popular feature-extraction paradigms in AI-based neuroimaging modeling: (1) computation of anatomical surfaces and volumes, (2) supervised learning with convolutional neural networks (CNNs), and (3) unsupervised pretraining of vision transformer (ViT) foundation models, followed by supervised finetuning. Our study is based on 18 publicly available datasets containing 3D structural T1-weighted MRI scans from approximately 80,000 participants across seven distinct clinical tasks. We observe that a linear model based on anatomical features matches the diagnostic performance of complex nonlinear features learned by sophisticated AI frameworks, including foundation models trained on thousands of scans. Conversely, CNNs and pretrained ViTs learn features that implicitly capture relevant anatomical information, bypassing the need for explicit feature extraction. Building upon these insights, we propose Anatomy Segmentation Pretraining (ASP), a novel method to incorporate anatomical information during foundation-model pretraining, which outperforms existing models in biological age estimation.

0.31

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.70
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

Unsupervised Adaptation of 3D CT Foundation Models for 3D CBCT Segmentation

cs.CV ·2026-08-27 ·Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon, Pietro Gori
publishedcode/data similarity 0.70
Abstract · Accepted at the EMA4MICCAI workshop at MICCAI 2026. 11 pages, 4 figures, 1 table. Code, trained models, weights, and liver annotations are a…

Accurate 3D segmentation of cone-beam CT (CBCT) is critical for interventional and radiation therapy applications, yet it remains limited by two compounding challenges: the scarcity of annotated CBCT data and the large domain shift from diagnostic CT. Interventional CBCT exhibits fundamental modality differences from conventional CT, driven by acquisition and physics effects as well as contrast-specific vascular content, thereby limiting effective cross-modality model transfer. We propose a novel unsupervised domain adaptation (UDA) framework based on redundancy-reducing feature alignment, enabling 3D CBCT segmentation with no target-domain annotations or inference-time adaptation. Our framework is architecture-agnostic, seamlessly adapting both CNN-based and ViT-based foundation models. We evaluate our method on two challenging CT-CBCT liver segmentation benchmarks: one for interventional vascular procedures and one for radiation therapy, demonstrating that even large-scale pretrained segmentation networks require explicit feature-space bridging to generalize across acquisition modalities, and that our approach consistently outperforms existing pretrained foundation model and UDA strategies. To support reproducibility and benchmarking, we release the liver segmentations for a public CBCT dataset, along with the code, trained models, and weights.

0.41

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.70
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.13