CS Paper Radar

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado

cs.CV cs.AI ·submitted 2026-11-17 08:31 UTC · v1
benchmark

Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

Closest papers

Nearest neighbours by meaning across the whole index.

Benchmarking Self-Supervised 3D Medical Vision Foundation Models and Transferability Estimation

cs.CV cs.AI ·2026-10-13 ·Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang +5 more
benchmark similarity 0.78
Abstract

Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fine-tuning protocols. Models also differ in architecture, pretraining objective and data, while downstream targets range from voxel-level masks to patient-level diagnoses and outcomes. As a result, published findings provide little directly comparable evidence for choosing a model for a new task. Direct comparison of adaptation performance requires fine-tuning candidates on labelled target data, at substantial computational cost. We benchmark 23 candidates across the same 14 segmentation, classification and regression tasks spanning multiple anatomies and modalities. No candidate ranked among the top three across all segmentation tasks or across all classification and regression tasks; a convolutional encoder could outperform a transformer trained with the same objective on one task but underperform it on another. We benchmark transferability estimators against the fine-tuned rankings and find that their agreement varies across dense segmentation, classification and regression. InsightRank uses task-appropriate frozen-feature statistics and architecture-aware pairwise comparisons to rank candidates before fine-tuning. Across the 23-model pool, mean Kendall tau-b was 0.431 for segmentation and 0.352 for classification and regression. The segmentation Top 3 contained a task winner on four of nine tasks; the image-level Top 3 contained none on the five tasks, despite better full-ranking agreement than the matched conventional estimators. A three-model shortlist reduced recorded extraction-plus-training job time by 85.8% across seven segmentation tasks. Together, the benchmark provides a common reference for model selection and InsightRank offers a lower-cost way to prioritize fine-tuning, with shortlist performance that differs by target type.

0.20

Less Is More in the Long Tail: Stage-Adaptive Sample Selection for Annotation-Efficient Dense Prediction

cs.CV ·2026-09-22 ·Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
similarity 0.73
Abstract

Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-scale dense prediction tasks with long-tailed category distributions, where pixel- or voxel-level annotation is prohibitively expensive. We propose SASS (Stage-Adaptive Sample Selection), a stage-adaptive data-selection framework for pool-based active learning in long-tailed dense prediction. SASS combines three components: label-free self-supervised gradient scoring, prior-guided category rebalancing with validation-driven feedback, and stage-adaptive acquisition aligned with model training dynamics. This design avoids candidate ground-truth masks during gradient scoring while making acquisition responsive to long-tail imbalance and evolving representations. We evaluate SASS on a multimodal 3D medical segmentation testbed comprising over 100,000 samples spanning 108 anatomical structures. SASS recovers 98.3% of full-dataset performance with a 40% training-pool annotation budget, outperforming BADGE by 5.1 percentage points. Moreover, SASS exhibits a statistically supported less-is-more pattern, surpassing full-dataset training at the Hard-group level and, at the structure level, for the pancreas and gallbladder. More broadly, SASS shows that annotation-efficient learning depends not only on which samples are selected, but also on how the annotation budget is distributed across categories and when model-derived scores begin to guide selection.

0.18

VoxForge: A Unified Foundation Model for Dense 3D Features Across MRI, CT and PET

cs.CV cs.LG ·2026-11-19 ·Rushil Anirudh, Jayaraman J. Thiagarajan
similarity 0.72
Abstract · 34 pages (8-page main paper, references, and 23-page supplementary material), 7 figures. Rushil Anirudh and Jayaraman J. Thiagarajan contrib…

A unified 3D medical foundation model promises reusable, frozen features that serve a wide variety of tasks such as segmentation, classification and registration on MRI, CT and PET as well as specialist models do. Generalist models still need separate backbones for localized and global tasks, specialist models are confined to a single modality, with the concern that spanning modalities under-emphasizes fine anatomy, and both typically rely on end-to-end fine-tuning to be competitive. We present VoxForge, a single encoder that integrates recent advances in 3D architecture, self-distillation and cross-modal curricula to learn transferable features from permissively licensed MRI and CT volumes. We evaluate it strictly frozen, the test a reusable foundation model must pass, against state-of-the-art generalist and specialist models on segmentation, classification and registration across MRI and CT, and on PET, which it never sees. VoxForge has the best or tied-best average rank in every task group, serves localized and global tasks across modalities at the level of state-of-the-art specialists, and is extremely label-efficient, matching top-performing models on TotalSegmentator CT with a tenth of the labels.

0.18

Multi-Stage Prompt-Guided Feature Modulation for Generalizable Brain Tumor Segmentation

eess.IV cs.CV ·2026-08-24 ·Mohammad Mahdi Danesh Pajouh, Sara Saeedi
published similarity 0.71
Abstract · Accepted to BraTS MICCAI 2026 Task 3 (Generalizability Across Tumors)

Accurate brain tumor segmentation from magnetic resonance imaging (MRI) is essential for diagnosis, treatment planning, surgical guidance, and disease monitoring. However, developing automated segmentation models that generalize across diverse tumor characteristics, imaging protocols, acquisition sites, and patient populations remains challenging. Variations in tumor morphology and imaging distributions can substantially degrade performance outside the training domain. Consequently, improving the robustness and generalization of deep learning-based segmentation models has become a key objective in medical image analysis. To improve segmentation robustness, we propose Multi-Stage Dynamic Prompt nnU-Net, a prompt-conditioned extension of nnU-Net. Three independent dynamic prompt modules are inserted into the deepest encoder stages. Each module contains a learnable bank of ten 256-dimensional prompt vectors and uses globally pooled encoder features to generate image-specific prompt representations. These representations are projected into feature-wise scaling $(γ)$ and shifting $(β)$ parameters that modulate encoder feature maps through Feature-wise Linear Modulation (FiLM), enabling adaptive feature conditioning at multiple semantic levels. Evaluation on the BraTS GOAT validation dataset demonstrated that the proposed Multi-Stage Dynamic Prompt nnU-Net outperformed the baseline nnU Net across the majority of evaluated metrics and tumor subregions. The proposed model achieved average lesion-wise Dice scores of 76.16% (ET), 80.04% (TC), and 86.42% (WT), compared with 74.38%, 78.14% and 84.01% for the baseline model. The results demonstrate that multi-stage dynamic prompt conditioning improves segmentation accuracy and boundary delineation for brain tumor segmentation.

0.21

Representation Learning for 3D Brain Imaging: A Benchmark

cs.CV ·2026-11-04 ·Pierre Falconnier, Robin Trombetta, Nicolas Duchateau, Carole Lartizien
top venuebenchmarkcode/data similarity 0.70
Abstract

Many deep learning architectures for computer vision tasks rely on features extracted by a pre-trained encoder on large databases of natural 2D RGB images. However, the wide domain gap with medical images hampers the direct transfer of optimized deep learning models from computer vision to clinical applications. Recently, self-supervised pre-training and foundation models emerged as promising alternatives to mitigate these limitations. Yet, constructing such models for medical imaging faces critical challenges, including designing and adapting training strategies for large 3D volume datasets, and the need for standardized benchmarks to evaluate feature extraction performance. In this study, we propose an extensive comparison of vision encoders with a focus on 3D brain MRI. First, we consider 8 fully and self-supervised models pretrained on natural images (e.g. ResNet, DINO, CLIP) and 10 backbone architectures trained on medical images, either based on supervised (e.g. RadImageNet) or self-supervised (e.g. BiomedCLIP, SimCLR) tasks. All pre-trained encoders are evaluated on various downstream tasks to assess the representation power of their latent representations, including age and sex prediction as well as disease classification on the ADNI and PPMI datasets. Our study shows that 2D encoders pre-trained on natural images perform the most favorably, even compared to models pre-trained on more than 100k brain MRI volumes, highlighting the need for more suitable and robust methods for representation learning in 3D medical imaging. The source code for this study is publicly available at: https: //github.com/PierreFalconnier/brain-representation-benchmark.

0.50

SUGFW+: An Uncertainty-guided Feature Weighting Framework for Cold Start Active Adaptation of SAM in Medical Image Segmentation

cs.CV ·2026-08-17 ·Xiaochuan Ma, Ning Zhu, Jia Fu, Lanfeng Zhong, Hanyu Jiang +3 more
code/data similarity 0.70
Abstract

Cold Start Active Learning (CSAL) is important in improving the performance of a medical image segmentation model with low annotation budget by querying a small subset for annotation from an unlabeled training set. Existing CSAL methods typically rely on inefficient dataset-specific Self-Supervised Learning (SSL) to map the unlabeled images into a feature space for sample selection. Recently, the advent of foundation models such as the Segment Anything Model (SAM) offer a promising alternative as the pre-trained model can provide strong generalizable feature embeddings, and allow high performance in downstream tasks after fine-tuning (adaptation). However, how to systematically exploit SAM's inherent embeddings for cold-start sample selection during adaptation with low annotation budget remains underexplored. To address this, we propose an extended SAM-based Uncertainty-guided Feature Weighting (SUGFW+) framework for CSAL and adaptation of SAM. Specifically, it leverages the SAM for Patch-level Feature and Uncertainty Calculation (PFUC), and introduces a Patch-based Global Distinct Representation (PGDR) module that aggregates patch-level embeddings into highly discriminative, uncertainty-aware image-level features. These features are then utilized by a Greedy Selection with Cluster and Uncertainty (GSCU) strategy to combine diversity and uncertainty during sample selection. Unlike prior CSAL methods that decouple sample selection from model training, SUGFW+ tightly integrates these two stages via an Uncertainty-Prompted Fine-Tuning (UPFT) process of SAM in model training. Extensive experiments on four public datasets demonstrate that SUGFW+ achieves state-of-the-art performance against existing CSAL methods. Code is available at https://github.com/HiLab-git/SUGFW-plus.

0.42

nnFoundation: 3D Foundation Models for Radiology

cs.CV eess.IV ·2026-09-22 ·Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp +78 more
similarity 0.70
Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

0.40

Lightweight Vision Transformer-Based U-Net for Brain Tumor Segmentation from MRI

cs.CV ·2026-09-24 ·Sheekar Banerjee, Md. Srabon Chowdhury, Md. Mahbub Hasan Akash, Ishtiak Al Mamoon
published similarity 0.70
Abstract · Accepted at The 2026 IEEE International Conference on Biomedical Engineering, Computer and Information Technology for Health (BECITHCON)

Accurate brain tumor segmentation from Magnetic Resonance Imaging is essential for diagnosis, treatment planning, and surgical guidance. Although Convolutional Neural Networks, particularly UNet, have achieved significant success in medical image segmentation, they often struggle to capture the long-range spatial dependencies required to model tumors with irregular shapes and complex boundaries. This paper proposes a lightweight Vision Transformer UNet that combines the hierarchical feature extraction capability of UNet with the global context modeling of Vision Transformers. The proposed architecture incorporates a compact ViT bottleneck within a U-Net encoder-decoder framework, enabling effective learning of both local and global features while maintaining computational efficiency with only 2.6 million trainable parameters. The model was evaluated on the TCGA LGG MRI Segmentation dataset, achieving a mean Intersection over Union of 0.8100 and a Dice score of 0.8446, outperforming the baseline UNet by 3.75% and 3.15%, respectively. Extensive quantitative and qualitative analyses, including confusion matrix evaluation, precision recall curves, per-image performance distribution, and tumor size dependency analysis, demonstrate the effectiveness and robustness of the proposed method for brain tumor segmentation.

0.14