CS Paper Radar

Benchmarking Self-Supervised 3D Medical Vision Foundation Models and Transferability Estimation

Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang, Zhou Zhen, Xiahai Zhuang, Qingchao Chen, Yining Yang, Yizhou Yu

cs.CV cs.AI ·submitted 2026-10-13 01:52 UTC · v1
benchmark

Abstract

Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fine-tuning protocols. Models also differ in architecture, pretraining objective and data, while downstream targets range from voxel-level masks to patient-level diagnoses and outcomes. As a result, published findings provide little directly comparable evidence for choosing a model for a new task. Direct comparison of adaptation performance requires fine-tuning candidates on labelled target data, at substantial computational cost. We benchmark 23 candidates across the same 14 segmentation, classification and regression tasks spanning multiple anatomies and modalities. No candidate ranked among the top three across all segmentation tasks or across all classification and regression tasks; a convolutional encoder could outperform a transformer trained with the same objective on one task but underperform it on another. We benchmark transferability estimators against the fine-tuned rankings and find that their agreement varies across dense segmentation, classification and regression. InsightRank uses task-appropriate frozen-feature statistics and architecture-aware pairwise comparisons to rank candidates before fine-tuning. Across the 23-model pool, mean Kendall tau-b was 0.431 for segmentation and 0.352 for classification and regression. The segmentation Top 3 contained a task winner on four of nine tasks; the image-level Top 3 contained none on the five tasks, despite better full-ranking agreement than the matched conventional estimators. A three-model shortlist reduced recorded extraction-plus-training job time by 85.8% across seven segmentation tasks. Together, the benchmark provides a common reference for model selection and InsightRank offers a lower-cost way to prioritize fine-tuning, with shortlist performance that differs by target type.

Closest papers

Nearest neighbours by meaning across the whole index.

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.78
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.18

Representation Learning for 3D Brain Imaging: A Benchmark

cs.CV ·2026-11-04 ·Pierre Falconnier, Robin Trombetta, Nicolas Duchateau, Carole Lartizien
top venuebenchmarkcode/data similarity 0.74
Abstract

Many deep learning architectures for computer vision tasks rely on features extracted by a pre-trained encoder on large databases of natural 2D RGB images. However, the wide domain gap with medical images hampers the direct transfer of optimized deep learning models from computer vision to clinical applications. Recently, self-supervised pre-training and foundation models emerged as promising alternatives to mitigate these limitations. Yet, constructing such models for medical imaging faces critical challenges, including designing and adapting training strategies for large 3D volume datasets, and the need for standardized benchmarks to evaluate feature extraction performance. In this study, we propose an extensive comparison of vision encoders with a focus on 3D brain MRI. First, we consider 8 fully and self-supervised models pretrained on natural images (e.g. ResNet, DINO, CLIP) and 10 backbone architectures trained on medical images, either based on supervised (e.g. RadImageNet) or self-supervised (e.g. BiomedCLIP, SimCLR) tasks. All pre-trained encoders are evaluated on various downstream tasks to assess the representation power of their latent representations, including age and sex prediction as well as disease classification on the ADNI and PPMI datasets. Our study shows that 2D encoders pre-trained on natural images perform the most favorably, even compared to models pre-trained on more than 100k brain MRI volumes, highlighting the need for more suitable and robust methods for representation learning in 3D medical imaging. The source code for this study is publicly available at: https: //github.com/PierreFalconnier/brain-representation-benchmark.

0.50

Less Is More in the Long Tail: Stage-Adaptive Sample Selection for Annotation-Efficient Dense Prediction

cs.CV ·2026-09-22 ·Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
similarity 0.73
Abstract

Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-scale dense prediction tasks with long-tailed category distributions, where pixel- or voxel-level annotation is prohibitively expensive. We propose SASS (Stage-Adaptive Sample Selection), a stage-adaptive data-selection framework for pool-based active learning in long-tailed dense prediction. SASS combines three components: label-free self-supervised gradient scoring, prior-guided category rebalancing with validation-driven feedback, and stage-adaptive acquisition aligned with model training dynamics. This design avoids candidate ground-truth masks during gradient scoring while making acquisition responsive to long-tail imbalance and evolving representations. We evaluate SASS on a multimodal 3D medical segmentation testbed comprising over 100,000 samples spanning 108 anatomical structures. SASS recovers 98.3% of full-dataset performance with a 40% training-pool annotation budget, outperforming BADGE by 5.1 percentage points. Moreover, SASS exhibits a statistically supported less-is-more pattern, surpassing full-dataset training at the Hard-group level and, at the structure level, for the pancreas and gallbladder. More broadly, SASS shows that annotation-efficient learning depends not only on which samples are selected, but also on how the annotation budget is distributed across categories and when model-derived scores begin to guide selection.

0.18

InnerLogic-Surg: An Open Surgical Foundation Model via Continual Pretraining

cs.CV cs.AI ·2026-11-05 ·Kun Yuan, Hao Ding, Yiqing Shen, Gasper Podobnik, Benjamin Killeen +3 more
benchmark similarity 0.71
Abstract

Vision foundation models are the backbone of modern surgical image analysis, yet most surgical systems still rely on encoders pretrained on natural images or on specialist models trained from scratch on comparatively small datasets. Pretraining encoders on large amounts of surgery-specific data has the potential to generally enhance the performance of surgical image analysis methods simply by providing stronger backbones. Here we present InnerLogic-Surg, an open family of surgical vision encoders (21M--300M parameters) obtained by continually pretraining a transformer-based image encoder on millions of surgical images curated from 11,965 internet-sourced surgical videos spanning ~2,900 hours and more than fifteen procedure types. Our training recipe inherits DINOv3's pretraining stage to preserve representation ability after surgical adaptation, and additionally applies a learned feature-upsampling module for high-resolution dense prediction at low token cost. Across a benchmark covering workflow, instrument and anatomy recognition, segmentation, detection, and monocular depth, under the same architecture, the largest InnerLogic-Surg model achieves the best linear-probe performance in all 20 surgical tasks. We demonstrate that surgical continual pretraining yields transferable representations that generalize across procedures, anatomical regions, and task types, showing our surgical image encoders as a promising and scalable alternative to the procedure-specific representation learning approaches that have traditionally dominated surgical computer vision.

0.25

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

cs.CV ·2026-11-06 ·Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
top venue similarity 0.70
Abstract · 32 pages, 6 figures, Accepted to NeurIPS 2026 ED Track

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

0.50

Where to Look Matters: Rethinking Sub-Volume Sampling in 3D Medical Self-supervised Learning

cs.CV ·2026-10-09 ·Junkai Liu, Le Zhang
publishedcode/data similarity 0.70
Abstract · NeurIPS 2026. Project page: https://volumeprobe.github.io/

Self-supervised learning on 3D medical images commonly relies on random sub-volume sampling during pretraining. However, random cropping implicitly treats all spatial regions as equally worth observing, despite anatomical priors and spatial redundancy that make regions inherently unequal in their value for representation learning. To this end, we first show through controlled crop-quality manipulations that better sub-volumes lead to better downstream transfer, revealing the observation policy as an overlooked bottleneck in 3D medical SSL. Motivated by this finding, we revisit sub-volume sampling as a where-to-look problem. We propose VolumeProbe, a plug-and-play framework that replaces random cropping with an offline coarse-to-fine probe bank guided by anatomy-awareness, informativeness, and diversity. We instantiate VolumeProbe as a lightweight Lite variant using geometric and image-statistical cues, and a diagnostic Feat variant using frozen visual features, to examine whether lightweight volume-intrinsic priors suffice or richer semantic cues reliably provide additional value. Extensive experiments across multiple 3D medical SSL backbones and downstream tasks demonstrate that VolumeProbe-Lite consistently improves transfer performance over random sampling. Mechanistic analyses further link these gains to more anatomically plausible and informative observations, reduced spatial redundancy, more efficient learning dynamics, and more structured representations.

0.22

Learning from Unlabeled Photographs for General Oral Image Analysis

cs.CV ·2026-11-03 ·Zhong-Shi Zhang, Zi-Li Yu, Xiao Xiao, Huan Liu, Gui-Song Xia +2 more
similarity 0.70
Abstract

Oral photographs contain rich clinical information and hold significant potential for artificial intelligence applications; however, most models are trained for individual tasks and rely on costly expert annotations. We hypothesized that self-supervised training on unlabeled oral photographs could produce transferable visual representations for heterogeneous vision tasks. To test this hypothesis, we developed DOVE (Dental Optical Visual Encoder) by domain-adaptive self-supervised pretraining on approximately 530,000 unlabeled oral photographs collected from publicly accessible sources. DOVE was benchmarked against 3 established baselines across 5 classification datasets and 4 segmentation datasets, covering both frozen backbone evaluation and end-to-end finetuning. DOVE achieved the strongest overall performance, ranking best in few-shot transfer and label efficiency on most benchmarks. Under the 20-shot frozen-backbone protocol, DOVE outperformed the second best DINOv3 by 4.37 percentage points in mean macro-F1 across classification datasets and by 4.49 percentage points in mean macro-Dice across segmentation tasks. Under end-to-end finetuning, DOVE achieved at least 80% of the strongest full-data baseline's performance across most evaluation datasets using only 10% of the labeled training data. Qualitative retrieval and feature analyses further indicated better organization of image-level and spatial representations. These findings support DOVE as a generalizable and label-efficient backbone for oral vision research.

0.17

Comparative Study of Anatomical and Learned Features in AI Models for Structural Brain MRI

cs.CV cs.AI ·2026-09-06 ·Boyang Yu, Miquel Lopez Escoriza, Long Chen, Arjun V. Masurkar, Narges Razavian +1 more
published similarity 0.69
Abstract

In this work, we comprehensively evaluate three popular feature-extraction paradigms in AI-based neuroimaging modeling: (1) computation of anatomical surfaces and volumes, (2) supervised learning with convolutional neural networks (CNNs), and (3) unsupervised pretraining of vision transformer (ViT) foundation models, followed by supervised finetuning. Our study is based on 18 publicly available datasets containing 3D structural T1-weighted MRI scans from approximately 80,000 participants across seven distinct clinical tasks. We observe that a linear model based on anatomical features matches the diagnostic performance of complex nonlinear features learned by sophisticated AI frameworks, including foundation models trained on thousands of scans. Conversely, CNNs and pretrained ViTs learn features that implicitly capture relevant anatomical information, bypassing the need for explicit feature extraction. Building upon these insights, we propose Anatomy Segmentation Pretraining (ASP), a novel method to incorporate anatomical information during foundation-model pretraining, which outperforms existing models in biological age estimation.

0.31