CS Paper Radar

Learning from Unlabeled Photographs for General Oral Image Analysis

Zhong-Shi Zhang, Zi-Li Yu, Xiao Xiao, Huan Liu, Gui-Song Xia, Cui Huang, Meng-Xun Li

cs.CV ·submitted 2026-11-03 11:28 UTC · v1

Abstract

Oral photographs contain rich clinical information and hold significant potential for artificial intelligence applications; however, most models are trained for individual tasks and rely on costly expert annotations. We hypothesized that self-supervised training on unlabeled oral photographs could produce transferable visual representations for heterogeneous vision tasks. To test this hypothesis, we developed DOVE (Dental Optical Visual Encoder) by domain-adaptive self-supervised pretraining on approximately 530,000 unlabeled oral photographs collected from publicly accessible sources. DOVE was benchmarked against 3 established baselines across 5 classification datasets and 4 segmentation datasets, covering both frozen backbone evaluation and end-to-end finetuning. DOVE achieved the strongest overall performance, ranking best in few-shot transfer and label efficiency on most benchmarks. Under the 20-shot frozen-backbone protocol, DOVE outperformed the second best DINOv3 by 4.37 percentage points in mean macro-F1 across classification datasets and by 4.49 percentage points in mean macro-Dice across segmentation tasks. Under end-to-end finetuning, DOVE achieved at least 80% of the strongest full-data baseline's performance across most evaluation datasets using only 10% of the labeled training data. Qualitative retrieval and feature analyses further indicated better organization of image-level and spatial representations. These findings support DOVE as a generalizable and label-efficient backbone for oral vision research.

Closest papers

Nearest neighbours by meaning across the whole index.

Generative AI-Based Data Augmentation for Oral Lesion Classification: The PhotoMOCI Dataset and Benchmark

cs.CV cs.AI ·2026-09-28 ·Marco Parola, Mario G. C. A. Cimino, Sabrina Senatore
publishedbenchmark similarity 0.73
Abstract

Early detection of oral cancer via photographic imaging presents a promising avenue for large-scale oral cavity screening. However, the development of robust deep learning models is frequently hampered by the scarcity of high-quality, annotated datasets. To address this limitation, a novel and well-curated resource, the Photographic Multi-purpose Oral Cancer Imaging (PhotoMOCI) dataset, is introduced for developing models across multiple diagnostic tasks in oral oncology. Then, a comprehensive benchmark study was conducted to investigate how various data augmentation strategies influence the performance of image classifiers. Our analysis spans different generative AI frameworks, evaluating the efficacy of traditional methods against advanced generative approaches, including Generative Adversarial Networks (GANs) and Diffusion Models (DMs). Additionally, we propose the Synthetic Image Filter (SIF), a mechanism to select specific samples based on two auxiliary models: Synthetic Proxy Classifier to ensure samples are representative of the target class and Synthetic Image Detector to verify they appear realistic, thereby selecting only the high-utility images that contribute to improving downstream performance. Across the evaluated datasets and classifiers, the best SIF-filtered setup improves accuracy over traditional augmentation in all cases, with gains of +1.73% and +2.35% on PhotoMOCI and +2.38% and +2.08% on KOCD for ResNet50 and ViT, respectively. Our findings reveal that while the direct application of generative data augmentation may yield performance drops, the integration of SIF, considering (i) how synthetic data looks real and (ii) how it reflects the discriminative features of the belonging class, provides a simple yet effective mechanism to filter out synthetic samples that confuse the classifier during training.

0.18

Benchmarking Self-Supervised 3D Medical Vision Foundation Models and Transferability Estimation

cs.CV cs.AI ·2026-10-13 ·Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang +5 more
benchmark similarity 0.70
Abstract

Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fine-tuning protocols. Models also differ in architecture, pretraining objective and data, while downstream targets range from voxel-level masks to patient-level diagnoses and outcomes. As a result, published findings provide little directly comparable evidence for choosing a model for a new task. Direct comparison of adaptation performance requires fine-tuning candidates on labelled target data, at substantial computational cost. We benchmark 23 candidates across the same 14 segmentation, classification and regression tasks spanning multiple anatomies and modalities. No candidate ranked among the top three across all segmentation tasks or across all classification and regression tasks; a convolutional encoder could outperform a transformer trained with the same objective on one task but underperform it on another. We benchmark transferability estimators against the fine-tuned rankings and find that their agreement varies across dense segmentation, classification and regression. InsightRank uses task-appropriate frozen-feature statistics and architecture-aware pairwise comparisons to rank candidates before fine-tuning. Across the 23-model pool, mean Kendall tau-b was 0.431 for segmentation and 0.352 for classification and regression. The segmentation Top 3 contained a task winner on four of nine tasks; the image-level Top 3 contained none on the five tasks, despite better full-ranking agreement than the matched conventional estimators. A three-model shortlist reduced recorded extraction-plus-training job time by 85.8% across seven segmentation tasks. Together, the benchmark provides a common reference for model selection and InsightRank offers a lower-cost way to prioritize fine-tuning, with shortlist performance that differs by target type.

0.20

CarDiff: Anatomically Aware Dental Caries Synthesis using Diffusion

cs.CV cs.LG ·2026-10-13 ·Sanyam Jain, Bruna Neves de Freitas, Alexandros Iosifidis, Ruben Pauwels
code/data similarity 0.69
Abstract

Synthetic medical image generation can help address limited annotated data in dental imaging, particularly for under-represented caries classes. In this work, we present CarDiff, a semi-supervised framework for dental caries synthesis in panoramic radiographs. The method combines paired mask-image learning with self-supervised generation from augmented masks, while incorporating anatomy-aware conditioning between lesion regions and surrounding structures. Semantic consistency is enforced through segmentation-guided supervision and adversarial anatomical alignment. Experiments on the MLUA-DC1000 dataset show that CarDiff achieves improved synthesis quality compared with existing semantic synthesis baselines, obtaining the best Fréchet Inception Distance (FID) (90.76) and Learned Perceptual Image Patch Similarity (LPIPS) (0.48) scores among evaluated methods. We further assess the generated radiographs for downstream segmentation augmentation across seven architectures. Using a 5x augmented training set improves average Dice score by up to 6.5%, with larger gains observed for medium and combined lesion classes. These results suggest that anatomically consistent diffusion synthesis may be useful for dental radiograph augmentation under limited supervision. The code is available at https://github.com/s4nyam/CarDiff.

0.32

Less Is More in the Long Tail: Stage-Adaptive Sample Selection for Annotation-Efficient Dense Prediction

cs.CV ·2026-09-22 ·Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
similarity 0.69
Abstract

Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-scale dense prediction tasks with long-tailed category distributions, where pixel- or voxel-level annotation is prohibitively expensive. We propose SASS (Stage-Adaptive Sample Selection), a stage-adaptive data-selection framework for pool-based active learning in long-tailed dense prediction. SASS combines three components: label-free self-supervised gradient scoring, prior-guided category rebalancing with validation-driven feedback, and stage-adaptive acquisition aligned with model training dynamics. This design avoids candidate ground-truth masks during gradient scoring while making acquisition responsive to long-tail imbalance and evolving representations. We evaluate SASS on a multimodal 3D medical segmentation testbed comprising over 100,000 samples spanning 108 anatomical structures. SASS recovers 98.3% of full-dataset performance with a 40% training-pool annotation budget, outperforming BADGE by 5.1 percentage points. Moreover, SASS exhibits a statistically supported less-is-more pattern, surpassing full-dataset training at the Hard-group level and, at the structure level, for the pancreas and gallbladder. More broadly, SASS shows that annotation-efficient learning depends not only on which samples are selected, but also on how the annotation budget is distributed across categories and when model-derived scores begin to guide selection.

0.18

OraRefer: Segmentation-Guided Multi-Photograph Fusion for Oral Cancer Screening with Guaranteed Patient-Level Sensitivity

cs.CV eess.IV ·2026-11-05 ·Rupam Mukherjee, Mehakdeep Singh, Shirin Dasgupta, Subhamoy Mandal
similarity 0.69
Abstract

Oral cancer and the oral potentially malignant disorders (OPMD) that can precede it are visible on the oral mucosa, which makes smartphone photographs a promising tool for screening. Deep learning models for this task classify individual photographs. However, screening refers patients, not photographs: a patient is usually photographed several times, and the referral decision must miss no more than a set share of patients with disease. We propose OraRefer, a patient-level screening model that reads each photograph with a segmentation-guided foundation model that conditions its class decision on the predicted lesion, combines all photographs of a patient with risk factors, and refers through a threshold with a finite-sample sensitivity guarantee. The model localizes the mouth itself, so inference needs no annotation. On 3000 photographs of 714 patients, patient-level fusion reaches an AUROC of 0.919 and outperforms attention-based multiple-instance learning. At a 90% sensitivity target, OraRefer detects 95% of patients with OPMD or cancer and misses 3 of 61 patients with cancer, at a specificity of 0.610. Because the threshold is calibrated without retraining, each clinic can set its own guaranteed operating point on a local calibration sample.

0.16

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.69
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.16

Expandable Modality Experts for Medical Vision-Language Learning

cs.CV ·2026-10-21 ·DM BAPPY, Eunsu Kim, Hanjoo Lee, Sung Hak Lee, Sangjeong Ahn
benchmark similarity 0.68
Abstract · 11 pages (main text), 42 pages (supplementary material), 2 main figures. Submitted to ICLR 2027

Learning across medical imaging modalities requires making use of images without paired text and accommodating new domains while retaining existing representations. We propose a medical vision-language technique built around an expandable bank of modality experts. Its Multiway Transformer combines shared visual computation with deterministically routed feed-forward experts and a separate text pathway. A modality-aware visual tokenizer supplies targets for masked pretraining on 19.4 million unpaired image rows across seven modalities; contrastive alignment then uses 3.23 million image-text pairs. Additional fundus and optical coherence tomography experts learn from paired data while the original image and text embedding paths remain frozen. With a ViT-Large backbone, the proposed technique achieves the best or tied-best result in 24 of 25 benchmark settings across nine modalities: 10 of 11 zero-shot classification benchmarks, all 10 linear probes, and all four retrieval benchmarks. Mean balanced accuracy is 0.674 for zero-shot classification and 0.856 for linear probing, and mean bidirectional retrieval recall is 20.70%. A separate three-seed sequential experiment with matched adaptation data yields fundus and OCT retrieval gains of 14.95 and 9.31 percentage points, with no measured loss on preceding fundus or pathology tasks. The preservation argument requires unchanged existing computation paths and inference conditions, and feature-identity checks verify retention on evaluated inputs. The proposed technique provides a modular approach to learning and expanding medical vision-language representations.

0.21

Representation Learning for 3D Brain Imaging: A Benchmark

cs.CV ·2026-11-04 ·Pierre Falconnier, Robin Trombetta, Nicolas Duchateau, Carole Lartizien
top venuebenchmarkcode/data similarity 0.67
Abstract

Many deep learning architectures for computer vision tasks rely on features extracted by a pre-trained encoder on large databases of natural 2D RGB images. However, the wide domain gap with medical images hampers the direct transfer of optimized deep learning models from computer vision to clinical applications. Recently, self-supervised pre-training and foundation models emerged as promising alternatives to mitigate these limitations. Yet, constructing such models for medical imaging faces critical challenges, including designing and adapting training strategies for large 3D volume datasets, and the need for standardized benchmarks to evaluate feature extraction performance. In this study, we propose an extensive comparison of vision encoders with a focus on 3D brain MRI. First, we consider 8 fully and self-supervised models pretrained on natural images (e.g. ResNet, DINO, CLIP) and 10 backbone architectures trained on medical images, either based on supervised (e.g. RadImageNet) or self-supervised (e.g. BiomedCLIP, SimCLR) tasks. All pre-trained encoders are evaluated on various downstream tasks to assess the representation power of their latent representations, including age and sex prediction as well as disease classification on the ADNI and PPMI datasets. Our study shows that 2D encoders pre-trained on natural images perform the most favorably, even compared to models pre-trained on more than 100k brain MRI volumes, highlighting the need for more suitable and robust methods for representation learning in 3D medical imaging. The source code for this study is publicly available at: https: //github.com/PierreFalconnier/brain-representation-benchmark.

0.50