CS Paper Radar

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

Shaojun Li, Xiaoyu Deng, Ikuo Keshi

eess.IV cs.CV ·submitted 2026-10-16 11:28 UTC · v1

Abstract

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

Comment
21 pages, 7 figures. Supplementary material included. Under review at Biomedical Signal Processing and Control

Closest papers

Nearest neighbours by meaning across the whole index.

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.71
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

A Comparative Study of GAN-Based Deep Learning Models for Pneumonia Detection in Chest X-Rays

cs.CV ·2026-09-05 ·Roshan Paudel, Aashish Ghimire, Pramod Acharya
similarity 0.71
Abstract

This study evaluates pneumonia classification in chest X-rays using VGG19, MobileNetV2, ResNet50, and a custom CNN, and explores Generative Adversarial Network (GAN)-based synthetic data augmentation. MobileNetV2 achieved the highest reported accuracy of 88% with balanced class-wise performance. The custom CNN achieved pneumonia recall of 92.67% and precision of 79.43%, highlighting a precision-recall trade-off. Accuracy, F1-score, precision, recall, confusion matrices, and training curves were used to assess performance. Synthetic pneumonia images were combined with real images to investigate whether augmentation could improve classification performance. In the reported VGG19 comparison, augmented-data training accuracy reached approximately 100%, while validation accuracy remained near 50%, below the real-data validation accuracy. This experiment therefore did not demonstrate a validation-performance benefit from GAN augmentation. The classifier comparison highlights differences in accuracy and pneumonia recall, while the augmentation experiment indicates the need for further evaluation of synthetic-image quality and training settings.

0.26

nnFoundation: 3D Foundation Models for Radiology

cs.CV eess.IV ·2026-09-22 ·Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp +78 more
similarity 0.70
Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

0.40

Frequency-consistent synthesis and selective transfer for medical image analysis

eess.IV cs.CV ·2026-11-06 ·Zhuhui Wang, Jianwei Zuo, Xin Peng, Kai Zhong, Xuliang Deng +1 more
similarity 0.68
Abstract · 40 pages, 5 figures

Complementary imaging is not always available, and realistic synthesis does not necessarily improve downstream analysis. Here we introduce a training framework linking medical image synthesis to task learning through adaptive frequency consistency and selective feature transfer. Image-specific frequency constraints encourage consistency of structure and detail. Features are transferred only when a teacher using synthetic images achieves a lower task-error score than the student by a task-specific margin on a labelled training sample. Evaluations across five datasets show improved translation fidelity with three adversarial and diffusion-based translators trained without paired supervision, alongside gains in brain-tumour segmentation on tumour-containing slices and lesion centre-point detection. All 105 reported paired comparisons yielded point estimates favouring the proposed methods, including 36 external translation comparisons on post?treatment MRI without retraining. These findings support synthetic modalities as task-oriented complements to acquired scans when complementary imaging is unavailable.

0.24

Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA PET Synthesis in Prostate Cancer

cs.CV physics.med-ph ·2026-08-11 ·Rashmi Bhaskara, Waleed M. Almutairi, Matthew Gopaulchan, Maram Musaad Alqurashi, Francis Asamoah +3 more
similarity 0.68
Abstract

Deep learning models that synthesize PET from CT or MRI can reduce patient dose and scanner demand, but are typically optimized with global losses such as L1 or mean squared error (MSE) that treat all voxels similarly. In whole-body PSMA-PET, tumor voxels occupy only a small fraction of the volume, yet carry the clinically relevant activity signal; as a result, models can achieve high structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) while still underestimating lesion activity or failing to preserve tumor-specific structure. Radiomics provides biologically meaningful descriptors of tumor intensity and texture, but direct radiomics conditioning is time-consuming because it requires feature extraction from delineated lesion regions. We propose LAFNO, a Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA-PET synthesis that replaces high-dimensional radiomics conditioning with two efficient CT-derived proxy channels. Motivated by radiomics analysis of PSMA-avid tumor core and peritumoral regions, LAFNO uses a contrast proxy for local density variation and a disorder proxy for local texture heterogeneity, both injected into the model bottleneck. LAFNO combines whole-volume reconstruction with lesion-level total lesion activity (TLA), tumor-core contrast, and peritumoral supervision. We evaluated LAFNO against four baseline architectures on the TCIA PSMA-PET-CT-Lesions dataset. LAFNO remained competitive on whole-volume image quality, achieving SSIM of 0.960 and 0.938 for 18F- and 68Ga-PSMA, respectively, while reducing per-patient TLA error to 48.3% and 64.0% for 18F- and 68Ga-PSMA, respectively, and achieving the highest tumor-core radiomics reproducibility across all feature classes for both tracers. Peritumoral reproducibility remained tracer-dependent, indicating that biological fidelity in synthetic PSMA-PET remains challenging.

0.04

When Two Tracers Disagree: An Investigation of Multimodal Fusion for Clinical PET/CT Segmentation

cs.CV ·2026-08-19 ·Jack A. Johnson, Bartłomiej W. Papież
publishedcode/data similarity 0.67
Abstract · 10 pages (8 pages main content and 2 pages of references), 2 figures, 2 tables, accepted to MICCAI 2026 Cancer Prevention, Detection, and In…

PSMA and FDG PET/CT visualise complementary biological information in prostate cancer. Combining both tracers could capture heterogeneous tumour phenotypes that may be missed by either alone, yet there is no consensus on effective deep learning architectures for fusing these modalities. We evaluated multimodal image-fusion strategies for automatic whole-body PET/CT lesion segmentation to estimate total tumour burden. Using the public DEEP-PSMA Challenge dataset, we trained tracer-specific 3D nnU-Net baselines and compared (i) early fusion with a single encoder and one decoder (OEOD) or two decoders (OETD), and (ii) intermediate fusion via a dual-encoder cross-attention U-Net (DECA-UNet). Tracer-specific baselines performed strongly (PSMA Dice = 0.93; FDG = 0.81). Fusion yielded mixed results: OEOD produced a combined Dice of 0.90 (on an easier, non-tracer-specific task), whilst the tracer-specific fusion models reached PSMA/FDG = 0.69/0.64 (OETD) and 0.76/0.57 (DECA-UNet). Whilst fusion often provided reasonable PSMA segmentation, FDG performance degraded and no strategy consistently exceeded the single-tracer baselines. Under the evaluated setting, tracer-specific models remain the stronger baseline; clinically useful gains from multimodal fusion will likely require architectures that better preserve tracer specific representations. Our code is available at: https://github.com/JackJ3636/DEEP_PSMA_code

0.45

3D CT-to-PET Translation via Latent Brownian Bridge Diffusion

cs.CV cs.AI ·2026-09-11 ·Sarita Mourya, Francesco Di Feola, Pierangelo Veltri, Paolo Soda
similarity 0.67
Abstract

Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and treatment planning. However, the widespread use of PET is limited by high radiation exposure, elevated costs, and restricted availability. To address these limitations, deep learning-based CT-to-PET translation has emerged as a promising approach for synthesizing PET-like information directly from CT images, although accurately modeling the large cross-modal gap remains challenging. In this work, we propose a 3D CT-to-PET translation framework based on latent Brownian Bridge Diffusion (BBDM). The method consists of two stages. First, a Variational Autoencoder (VAE) is trained on paired CT-PET patches, integrating contrastive learning to improve latent alignment between anatomical and metabolic representations. Second, a BBDM is trained in the latent space to translate CT latent representations into their corresponding PET counterparts. The translated PET latents are then decoded and stitched to reconstruct the final 3D PET volume. We evaluate the proposed approach on two publicly available datasets. Quantitative results based on image fidelity and lesion-level PET-specific metrics demonstrate improved performance compared with competing methods. In particular, the proposed approach improves PET signal fidelity, better preserves clinically relevant uptake patterns, and shows improved performance in preserving small-lesion metabolic activation, paving the way for virtual imaging applications.

0.22

Does DCGAN-Based Synthetic Augmentation Improve Brain Tumor MRI Classification? An Empirical Study

eess.IV cs.CV ·2026-09-20 ·Irhum Jawad Khan, Talha bin Aslam
similarity 0.67
Abstract

Generative adversarial networks (GANs) are increasingly used to augment medical imaging datasets, but synthetic images do not necessarily provide downstream classification benefits. This study investigates whether class-specific Deep Convolutional Generative Adversarial Network (DCGAN) augmentation improves brain tumor classification when the classifier and evaluation set are held constant. Experiments were conducted on 7,200 brain magnetic resonance imaging (MRI) scans across four classes: glioma, meningioma, pituitary tumor, and no tumor. For each class, 1,400 real images were used for training and 400 were reserved for testing. A baseline Swin Transformer classifier was trained using only the real training images and compared with a second model trained using the same real images augmented with 500 DCGAN-generated images per class. Both conditions were evaluated on the identical held-out test set. The two models achieved the same overall accuracy of 96%, while macro F1 remained effectively unchanged and ROC-AUC decreased slightly from 0.987 to 0.982 after augmentation. Class-level analysis showed small redistributions in errors rather than a consistent performance gain. FID values between real and synthetic images ranged from 209.15 to 314.27, indicating substantial distributional differences under the adopted evaluation setup. These results suggest that synthetic augmentation should not be assumed to improve medical image classification and should instead be evaluated for both distributional fidelity and downstream task utility.

0.18