CS Paper Radar

A Comparative Study of GAN-Based Deep Learning Models for Pneumonia Detection in Chest X-Rays

Roshan Paudel, Aashish Ghimire, Pramod Acharya

cs.CV ·submitted 2026-09-05 22:04 UTC · v1

Abstract

This study evaluates pneumonia classification in chest X-rays using VGG19, MobileNetV2, ResNet50, and a custom CNN, and explores Generative Adversarial Network (GAN)-based synthetic data augmentation. MobileNetV2 achieved the highest reported accuracy of 88% with balanced class-wise performance. The custom CNN achieved pneumonia recall of 92.67% and precision of 79.43%, highlighting a precision-recall trade-off. Accuracy, F1-score, precision, recall, confusion matrices, and training curves were used to assess performance. Synthetic pneumonia images were combined with real images to investigate whether augmentation could improve classification performance. In the reported VGG19 comparison, augmented-data training accuracy reached approximately 100%, while validation accuracy remained near 50%, below the real-data validation accuracy. This experiment therefore did not demonstrate a validation-performance benefit from GAN augmentation. The classifier comparison highlights differences in accuracy and pneumonia recall, while the augmentation experiment indicates the need for further evaluation of synthetic-image quality and training settings.

Closest papers

Nearest neighbours by meaning across the whole index.

Pneumonia Detection on Chest X-Rays Derived from a U-Net Segmentation Model

eess.IV ·2026-10-15 ·Manasvini Singh
similarity 0.74
Abstract · 6 pages, 3 figures, 6 tables

Pneumonia killed more than 740,000 children under the age of five in 2019, and it can be difficult to recognize on chest radiographs (CXRs): opacities may be faint in early disease, may sit behind the equally bright heart shadow, and may resemble other lung conditions. Most deep learning systems treat pneumonia detection as a yes-or-no classification task. This paper asks whether a model trained on a harder task, segmenting pneumonia pixel by pixel, can be turned into an effective detector for the simpler task of deciding whether an image contains pneumonia at all. The hypothesis is that the detailed supervision of segmentation forces the network to learn where and what the disease looks like, producing a better detector than training for detection alone. A U-Net was trained to segment pneumonia on the RSNA Pneumonia Detection Challenge dataset of 26,684 radiographs, whose rectangular bounding boxes were converted into pixel masks. The data are heavily imbalanced: 22.5% of images are positive, and only 2.6% of pixels fall inside a box, so focal loss with α = 0.25 and γ = 2 and dropout were needed for the model to learn. On the harder segmentation task, the model reached a pixel-level F1 score of 0.45 on a held-out test set of 2,668 images. Applied to the simpler detection task, the same model reached a precision of 0.71, recall of 0.52, and F1 score of 0.60, with 91% specificity, and consistent scores on the development set. These results show that a segmentation-trained model transfers to detection while also showing where the suspected disease is. A direct comparison with a classifier trained only for detection on the same data is needed to confirm whether the segmentation-first approach is better, and is the main direction for future work.

0.18

Does DCGAN-Based Synthetic Augmentation Improve Brain Tumor MRI Classification? An Empirical Study

eess.IV cs.CV ·2026-09-20 ·Irhum Jawad Khan, Talha bin Aslam
similarity 0.72
Abstract

Generative adversarial networks (GANs) are increasingly used to augment medical imaging datasets, but synthetic images do not necessarily provide downstream classification benefits. This study investigates whether class-specific Deep Convolutional Generative Adversarial Network (DCGAN) augmentation improves brain tumor classification when the classifier and evaluation set are held constant. Experiments were conducted on 7,200 brain magnetic resonance imaging (MRI) scans across four classes: glioma, meningioma, pituitary tumor, and no tumor. For each class, 1,400 real images were used for training and 400 were reserved for testing. A baseline Swin Transformer classifier was trained using only the real training images and compared with a second model trained using the same real images augmented with 500 DCGAN-generated images per class. Both conditions were evaluated on the identical held-out test set. The two models achieved the same overall accuracy of 96%, while macro F1 remained effectively unchanged and ROC-AUC decreased slightly from 0.987 to 0.982 after augmentation. Class-level analysis showed small redistributions in errors rather than a consistent performance gain. FID values between real and synthetic images ranged from 209.15 to 314.27, indicating substantial distributional differences under the adopted evaluation setup. These results suggest that synthetic augmentation should not be assumed to improve medical image classification and should instead be evaluated for both distributional fidelity and downstream task utility.

0.18

Generative AI-Based Data Augmentation for Oral Lesion Classification: The PhotoMOCI Dataset and Benchmark

cs.CV cs.AI ·2026-09-28 ·Marco Parola, Mario G. C. A. Cimino, Sabrina Senatore
publishedbenchmark similarity 0.71
Abstract

Early detection of oral cancer via photographic imaging presents a promising avenue for large-scale oral cavity screening. However, the development of robust deep learning models is frequently hampered by the scarcity of high-quality, annotated datasets. To address this limitation, a novel and well-curated resource, the Photographic Multi-purpose Oral Cancer Imaging (PhotoMOCI) dataset, is introduced for developing models across multiple diagnostic tasks in oral oncology. Then, a comprehensive benchmark study was conducted to investigate how various data augmentation strategies influence the performance of image classifiers. Our analysis spans different generative AI frameworks, evaluating the efficacy of traditional methods against advanced generative approaches, including Generative Adversarial Networks (GANs) and Diffusion Models (DMs). Additionally, we propose the Synthetic Image Filter (SIF), a mechanism to select specific samples based on two auxiliary models: Synthetic Proxy Classifier to ensure samples are representative of the target class and Synthetic Image Detector to verify they appear realistic, thereby selecting only the high-utility images that contribute to improving downstream performance. Across the evaluated datasets and classifiers, the best SIF-filtered setup improves accuracy over traditional augmentation in all cases, with gains of +1.73% and +2.35% on PhotoMOCI and +2.38% and +2.08% on KOCD for ResNet50 and ViT, respectively. Our findings reveal that while the direct application of generative data augmentation may yield performance drops, the integration of SIF, considering (i) how synthetic data looks real and (ii) how it reflects the discriminative features of the belonging class, provides a simple yet effective mechanism to filter out synthetic samples that confuse the classifier during training.

0.18

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

eess.IV cs.CV ·2026-10-16 ·Shaojun Li, Xiaoyu Deng, Ikuo Keshi
similarity 0.71
Abstract · 21 pages, 7 figures. Supplementary material included. Under review at Biomedical Signal Processing and Control

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

0.17

Enhancing Deep Learning Model Performance through Data Generation Strategies: Classification of Olive Tree Diseases

cs.AI ·2026-10-26 ·Hicham El Akhal, Abderrahim Waga, Aissa Ben Yahya, Abdelbaki El Belrhiti El Alaoui
similarity 0.71
Abstract

Deep learning models are highly effective in a wide range of domains, particu larly in plant disease diagnosis. However, their performance is often limited by challenges such as insufficient data and class imbalance. In our work, we propose a comprehensive data generation strategy to overcome these limitations. First, we apply various data generation techniques, including traditional augmentation methods, CutMix, MixUp, and synthetic image generation using Deep Convolu tional Generative Adversarial Networks (DCGANs), to create new data samples. Second, we exploit this generated data in three scenarios: (S1) balancing class distribution in the original dataset, (S2) increasing the number of samples per class, and (S3) expanding the dataset while maintaining balanced classes. Third, we evaluate the impact of these data distributions (S1, S2, S3) on model perfor mance using the EfficientNetV2B0 architecture with pre-trained and fine-tuned weights. The experimental results show a substantial improvement in classifica tion accuracy, emphasizing the critical role of data diversity and class balance. These findings highlight the effectiveness and adaptability of the proposed strat egy of data generation and distribution for enhancing dataset quality, offering promising applications in plant disease detection and precision agriculture.

0.18

Overview of the ImageCLEFmedical 2026 GANs task: Exploring fingerprint detection, privacy leakage, and synthetic medical image generation

cs.CV ·2026-11-06 ·Alexandra-Georgiana Andrei, Mihai Gabriel Constantin, Mihai Dogariu, Dzmitry Karpenka, Yuri Prokopchuk +6 more
publishedsurveybenchmark similarity 0.70
Abstract · CLEF 2026 Working Notes, 21-24 September 2026, Jena, Germany

The 2026 ImageCLEFmedical GANs Task Exploring Fingerprint Detection, Privacy Leakage, and Synthetic Medical Image Generation continues to investigate privacy and security concerns around using patient data to generate synthetic medical images, now in its fourth edition. This edition introduces three complementary subtasks: the first extends prior editions by asking participants to detect which real images were used in training a Generative Adversarial Network to produce given synthetic outputs; the second is a novel subtask requiring participants to identify which latent vector produced each synthetic image, probing the faithfulness and reversibility of the latent-to-image mapping; the third asks participants to generate privacy-preserving CT slices, quantifying the trade-off between image fidelity and patient privacy. Ground-truth annotations and benchmark datasets of real and GAN-generated lung CT slices are provided for all subtasks. Evaluation is based on Cohen's Kappa for Subtask 1, matching accuracy for Subtask 2, and a combination of FID and Privacy Preservation Score (PPS) for Subtask 3. Overall, 37 teams registered for the task, with 10 teams submitting runs across subtasks and 6 teams submitting working notes papers. This paper presents an overview of the task setup, datasets, evaluation metrics, and summarises the approaches and results of participating teams.

0.38

Semi-Supervised GAN-Based Segmentation of CTPA Scans for Pulmonary Emboli Boundary Extraction

cs.CV cs.LG ·2026-11-18 ·Maria Thoma, Michalis Savelonas, Foteini Malli, Dimitris Iakovidis
published similarity 0.69
Abstract · 2026 IEEE 39th International Symposium on Computer-Based Medical Systems (CBMS), Limassol, Cyprus

Pulmonary embolism (PE) is a pulmonary vascular disease associated with high morbidity and mortality, where delayed diagnosis can be fatal. While computed tomography pulmonary angiography (CTPA) is the clinical gold standard for PE detection, interpreting these scans manually is time-consuming and error-prone. In this work, we propose a semi-supervised segmentation method, employing generative adversarial networks (GANs) to leverage large pools of unlabeled CTPA scans. The proposed method addresses more effectively the challenges of CTPA image segmentation than previous methods by employing the dice loss and the cross-entropy loss to tackle the highly imbalanced nature of CTPA scans, the feature matching loss to encourage the generator to produce anatomically plausible segmentation maps that are indistinguishable from ground truth, as well as the self-training loss to reinforce learning from highly-confident pseudo-labeled samples. The experimental evaluation on a publicly available dataset shows that the proposed method maintains accurate segmentation, despite a limited number of labeled CTPA scans. with a Dice coefficient of 88.75% and a 95th percentile Hausdorff distance (HD95) of 1.74, outperforming fully supervised baselines.

0.27

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.69
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06