CS Paper Radar

Semi-Supervised GAN-Based Segmentation of CTPA Scans for Pulmonary Emboli Boundary Extraction

Maria Thoma, Michalis Savelonas, Foteini Malli, Dimitris Iakovidis

cs.CV cs.LG ·submitted 2026-11-18 08:09 UTC · v1
published

Abstract

Pulmonary embolism (PE) is a pulmonary vascular disease associated with high morbidity and mortality, where delayed diagnosis can be fatal. While computed tomography pulmonary angiography (CTPA) is the clinical gold standard for PE detection, interpreting these scans manually is time-consuming and error-prone. In this work, we propose a semi-supervised segmentation method, employing generative adversarial networks (GANs) to leverage large pools of unlabeled CTPA scans. The proposed method addresses more effectively the challenges of CTPA image segmentation than previous methods by employing the dice loss and the cross-entropy loss to tackle the highly imbalanced nature of CTPA scans, the feature matching loss to encourage the generator to produce anatomically plausible segmentation maps that are indistinguishable from ground truth, as well as the self-training loss to reinforce learning from highly-confident pseudo-labeled samples. The experimental evaluation on a publicly available dataset shows that the proposed method maintains accurate segmentation, despite a limited number of labeled CTPA scans. with a Dice coefficient of 88.75% and a 95th percentile Hausdorff distance (HD95) of 1.74, outperforming fully supervised baselines.

Comment
2026 IEEE 39th International Symposium on Computer-Based Medical Systems (CBMS), Limassol, Cyprus
DOI
10.1109/CBMS69103.2026.00315

Closest papers

Nearest neighbours by meaning across the whole index.

A Comparative Study of GAN-Based Deep Learning Models for Pneumonia Detection in Chest X-Rays

cs.CV ·2026-09-05 ·Roshan Paudel, Aashish Ghimire, Pramod Acharya
similarity 0.69
Abstract

This study evaluates pneumonia classification in chest X-rays using VGG19, MobileNetV2, ResNet50, and a custom CNN, and explores Generative Adversarial Network (GAN)-based synthetic data augmentation. MobileNetV2 achieved the highest reported accuracy of 88% with balanced class-wise performance. The custom CNN achieved pneumonia recall of 92.67% and precision of 79.43%, highlighting a precision-recall trade-off. Accuracy, F1-score, precision, recall, confusion matrices, and training curves were used to assess performance. Synthetic pneumonia images were combined with real images to investigate whether augmentation could improve classification performance. In the reported VGG19 comparison, augmented-data training accuracy reached approximately 100%, while validation accuracy remained near 50%, below the real-data validation accuracy. This experiment therefore did not demonstrate a validation-performance benefit from GAN augmentation. The classifier comparison highlights differences in accuracy and pneumonia recall, while the augmentation experiment indicates the need for further evaluation of synthetic-image quality and training settings.

0.26

Unified CT and MRI Pancreas Segmentation for Label-Efficient Cross-Modality Subregion Transfer

cs.CV cs.AI ·2026-09-11 ·Ziliang Hong, Hongyi Pan, Halil Ertugrul Aktas, Andrea Bejar, Elif Keles +5 more
similarity 0.69
Abstract

Robust medical image segmentation across imaging modalities is challenging because of large differences in appearance and intensity distributions. Models trained on a single modality often show substantial performance drops when applied to unseen domains. In this work, we develop a unified 3D pancreas segmentation framework that applies domain-adversarial learning to 4,604 heterogeneous CT and MRI scans to learn anatomical representations. A shared nnU-Net encoder-decoder is trained for whole-pancreas segmentation, with a latent domain discriminator encouraging CT-MRI feature alignment. The learned encoder is subsequently transferred to pancreatic head-body-tail segmentation using limited MRI-only subregion annotations. An average Dice score of 87.31% on the in-distribution test set and Dice scores ranging from 84.20% to 88.09% across external OOD datasets were achieved in whole pancreas segmentation. Dice scores of 80.53% on MRI and 83.05% on CT were achieved for downstream subregion segmentation, without using CT subregion annotations. These results demonstrate that a unified anatomical representation can support both cross-modality pancreas segmentation and label-efficient downstream transfer.

0.42

UI-VISA: U-Net Initialized Vascular Image Segmentation Architecture

cs.CV ·2026-09-01 ·Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
similarity 0.67
Abstract · 9 pages, 6 figures

Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branching nature of blood vessels. Pixel-wise deep learning approaches such as U-Net achieve strong general-purpose segmentation performance but often produce fragmented or discontinuous predictions in fine vascular regions, since they do not explicitly enforce structural connectivity. Region growing algorithms preserve spatial context and topological continuity, but are highly sensitive to seed point initialization and can be computationally expensive. We propose UI-VISA (U-Net Initialized Vascular Image Segmentation Architecture), a hybrid pipeline that combines the complementary strengths of both approaches. UI-VISA uses U-Net's foreground predictions as informed seed points for a CNN-guided region growing algorithm, which then iteratively refines the segmentation by enforcing local connectivity and recovering fine vessel details that U-Net alone tends to miss or over-predict. We evaluate UI-VISA against standalone U-Net and a prior region-growing-based method (VISA) using 5-fold cross-validation on 26 DSA images. UI-VISA achieves the highest mean Dice and clDice scores across folds, and a paired Wilcoxon signed-rank test shows the improvement in clDice is statistically significant ($p=0.023$), consistent with the method's design goal of preserving vascular connectivity, while the improvement in Dice does not reach significance ($p=0.104$).

0.22

Overview of the ImageCLEFmedical 2026 GANs task: Exploring fingerprint detection, privacy leakage, and synthetic medical image generation

cs.CV ·2026-11-06 ·Alexandra-Georgiana Andrei, Mihai Gabriel Constantin, Mihai Dogariu, Dzmitry Karpenka, Yuri Prokopchuk +6 more
publishedsurveybenchmark similarity 0.66
Abstract · CLEF 2026 Working Notes, 21-24 September 2026, Jena, Germany

The 2026 ImageCLEFmedical GANs Task Exploring Fingerprint Detection, Privacy Leakage, and Synthetic Medical Image Generation continues to investigate privacy and security concerns around using patient data to generate synthetic medical images, now in its fourth edition. This edition introduces three complementary subtasks: the first extends prior editions by asking participants to detect which real images were used in training a Generative Adversarial Network to produce given synthetic outputs; the second is a novel subtask requiring participants to identify which latent vector produced each synthetic image, probing the faithfulness and reversibility of the latent-to-image mapping; the third asks participants to generate privacy-preserving CT slices, quantifying the trade-off between image fidelity and patient privacy. Ground-truth annotations and benchmark datasets of real and GAN-generated lung CT slices are provided for all subtasks. Evaluation is based on Cohen's Kappa for Subtask 1, matching accuracy for Subtask 2, and a combination of FID and Privacy Preservation Score (PPS) for Subtask 3. Overall, 37 teams registered for the task, with 10 teams submitting runs across subtasks and 6 teams submitting working notes papers. This paper presents an overview of the task setup, datasets, evaluation metrics, and summarises the approaches and results of participating teams.

0.38

NoduleFlow: Automatic 3D Lung Nodule Detection and Segmentation

cs.CV ·2026-10-12 ·Giulia Romoli, Filippo Ruffini, Francesco Di Feola, Valerio Guarrasi, Matteo Tortora +1 more
similarity 0.66
Abstract

Low dose Computed Tomography (CT) is the standard imaging modality for lung cancer screening. On CT scans, lung cancer typically manifests as pulmonary nodules, whose manual identification is time-consuming and prone to observer variability, image quality limitations, and suboptimal reading conditions. Moreover, subtle temporal changes are often difficult to quantify reliably in CT scans from the same patient across follow-up examinations. Deep learning-based approaches for the automatic detection and segmentation of lung nodules have demonstrated improved accuracy and efficiency. However, most existing approaches provide only coarse region-of-interest localisation, rely on prior lesion annotations or human supervision, or treat detection and segmentation as separate tasks. In this work, we present NoduleFlow, a framework for lung nodule detection, classification, and segmentation directly from series of CT volumes. Our proposal consists of four interconnected modules and operates in an automated manner at inference time, without requiring prior lesion annotations, manual initialisation, or region-of-interest pre-selection. We further investigate whether nodule localization benefits from the propagation of candidate regions across follow-up scans through inter-scan registration fields, as opposed to conventional independent per-scan analysis. The generalisability of the framework is systematically evaluated across four independent datasets. The results underscore the potential of automated pipelines for lung nodule analysis in screening and diagnostic settings.

0.14

Does DCGAN-Based Synthetic Augmentation Improve Brain Tumor MRI Classification? An Empirical Study

eess.IV cs.CV ·2026-09-20 ·Irhum Jawad Khan, Talha bin Aslam
similarity 0.65
Abstract

Generative adversarial networks (GANs) are increasingly used to augment medical imaging datasets, but synthetic images do not necessarily provide downstream classification benefits. This study investigates whether class-specific Deep Convolutional Generative Adversarial Network (DCGAN) augmentation improves brain tumor classification when the classifier and evaluation set are held constant. Experiments were conducted on 7,200 brain magnetic resonance imaging (MRI) scans across four classes: glioma, meningioma, pituitary tumor, and no tumor. For each class, 1,400 real images were used for training and 400 were reserved for testing. A baseline Swin Transformer classifier was trained using only the real training images and compared with a second model trained using the same real images augmented with 500 DCGAN-generated images per class. Both conditions were evaluated on the identical held-out test set. The two models achieved the same overall accuracy of 96%, while macro F1 remained effectively unchanged and ROC-AUC decreased slightly from 0.987 to 0.982 after augmentation. Class-level analysis showed small redistributions in errors rather than a consistent performance gain. FID values between real and synthetic images ranged from 209.15 to 314.27, indicating substantial distributional differences under the adopted evaluation setup. These results suggest that synthetic augmentation should not be assumed to improve medical image classification and should instead be evaluated for both distributional fidelity and downstream task utility.

0.18

CNVAE: Anatomically Correct Segmentation via Conditional Generative Modeling

eess.IV ·2026-11-04 ·Freddy Jiang, Loic Le Folgoc, Elsa Angelini
similarity 0.65
Abstract

Supervised deep learning segmentation models, although unparalleled in performance, are not immune to anatomical mistakes. We develop a segmentation-by-generation paradigm extending the Nouveau VAE (NVAE) generative framework for anatomically correct cardiac segmentation. In particular, we propose a novel conditional NVAE model (CNVAE) for conditional shape generation, and explore its capabilities for image segmentation in two scenarios: (1) direct image-to-mask CNVAE for one-step segmentation; (2) mask-to-mask CNVAE for refinement of segmentation masks produced by third-party segmentation models. Both models are lightweight and return consistently anatomically valid segmentation masks (> 98% success rate, an improvement of 15% above state-of-the-art segmentation models) on the cardiac segmentation/editing tasks of interest, without loss of accuracy in segmented contours.

0.25

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.65
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28