CS Paper Radar

Unified CT and MRI Pancreas Segmentation for Label-Efficient Cross-Modality Subregion Transfer

Ziliang Hong, Hongyi Pan, Halil Ertugrul Aktas, Andrea Bejar, Elif Keles, Frank H. Miller, Michael B. Wallace, Rajesh N. Keswani, Gorkem Durak, Ulas Bagci

cs.CV cs.AI ·submitted 2026-09-11 16:40 UTC · v1

Abstract

Robust medical image segmentation across imaging modalities is challenging because of large differences in appearance and intensity distributions. Models trained on a single modality often show substantial performance drops when applied to unseen domains. In this work, we develop a unified 3D pancreas segmentation framework that applies domain-adversarial learning to 4,604 heterogeneous CT and MRI scans to learn anatomical representations. A shared nnU-Net encoder-decoder is trained for whole-pancreas segmentation, with a latent domain discriminator encouraging CT-MRI feature alignment. The learned encoder is subsequently transferred to pancreatic head-body-tail segmentation using limited MRI-only subregion annotations. An average Dice score of 87.31% on the in-distribution test set and Dice scores ranging from 84.20% to 88.09% across external OOD datasets were achieved in whole pancreas segmentation. Dice scores of 80.53% on MRI and 83.05% on CT were achieved for downstream subregion segmentation, without using CT subregion annotations. These results demonstrate that a unified anatomical representation can support both cross-modality pancreas segmentation and label-efficient downstream transfer.

Closest papers

Nearest neighbours by meaning across the whole index.

Segment Anything Pancreas: A Unified MRI Segmentation Model for Pancreatic Cancer Radiotherapy

cs.CV ·2026-10-29 ·Zach Eidex, Mojtaba Safari, Kundan Thind, Parag J. Parikh, Zhen Tian +1 more
similarity 0.76
Abstract

Background: Limited tumor annotations and incomplete labels across MRI datasets hinder unified segmentation of pancreatic tumors and organs at risk (OARs) for MRI-guided radiotherapy. Purpose: We propose Pancreas-MedNeXt, a unified model that segments the whole pancreas, its subregions, tumors, and surrounding OARs from one MRI volume. Methods: The model uses a shared MedNeXt encoder-decoder with supervised whole-pancreas and subregion pretraining, followed by multitask fine-tuning. Three output heads predict the pancreatic subregions, tumor, and OARs (stomach, duodenum, kidneys). An annotation-aware loss allows training on partially labeled data without treating unannotated structures as background. Pancreas and tumor were evaluated by three-fold cross-validation on 142 PANTHER patients (92 diagnostic, 50 MR-Linac), subregions and OARs on Cyst-X and AMOS test sets, and pancreas and OARs on 33 external T1-weighted TotalSegmentator scans. Comparisons with nnU-Net, MedNeXt, VISTA3D, and Swin UNETR used the Dice similarity coefficient (DSC) with paired bootstrap 95% CIs. Results: Pancreas-MedNeXt achieved the highest mean pancreas and tumor DSC on diagnostic and MR-Linac MRI. Tumor DSC was 58.41% and 42.55%, exceeding task-specific MedNeXt by 4.94 (95% CI: 0.28-9.45) and 5.89 (95% CI: 2.37-9.72) percentage points, respectively. Whole-pancreas DSC was 85.73% and 70.66%. Pretraining improved head, body, and tail DSC by 2.01, 3.00, and 3.78 percentage points over training from scratch. It also achieved the highest DSC for the pancreas, duodenum, and right kidney on AMOS, and for all five organs on external MRI, exceeding the next-best method by 4.92-8.85 percentage points.Conclusion: A single Pancreas-MedNeXt model segments tumors, pancreatic subregions, and OARs on diagnostic and MR-Linac MRI, which could streamline contouring for pancreatic cancer radiotherapy.

0.19

TRIUNE-Net: Harmonizing Scale, Shape, and Efficiency in Pancreatic Tumor Segmentation

cs.CV ·2026-09-08 ·Amir Hossein Saleknia, Alireza Kheyrkhah, Sanaz Karimijafarbigloo, Reza Azad, Sina Houshmand +3 more
code/data similarity 0.71
Abstract

Pancreatic tumor segmentation in 3D CT volumes is challenged by extreme scale variability across both the pancreas and tumor, and highly irregular tumor morphology. While recent advances have pushed segmentation performance, existing methods do not explicitly address these challenges and come at the cost of excessive computational complexity, limiting their practicality in resource-constrained clinical environments. We propose TRIUNE-Net, a lightweight unified architecture that harmonizes scale, shape, and efficiency through three synergistic innovations. A multi-scale context aggregation module with stage-adaptive dilated convolutions enables the model to reason across the broad range of anatomical scales present in both organs. A serial linear-deformable attention mechanism combines large effective receptive fields with shapeadaptive deformable convolutions to capture irregular, non-convex tumor morphologies. Finally, an information-preserving downsampling module replaces conventional max pooling entirely, retaining all spatial information while adding negligible parameters, preventing small tumors from being discarded before they can be recognized. On both the MSD Pancreas and NVD Pancreas datasets, TRIUNE-Net achieves state-of-theart results with only 5.86 M parameters and no external pre-training, outperforming all baselines across all key tumor metrics. Specifically, it surpasses the next-best model by 0.45% in tumor Dice, 6.0 points in F1 score, 6.6 points in sensitivity, and 3.4 points in precision, simultaneously reflecting its ability to suppress both missed tumors and false alarms in clinically realistic conditions. Our code is available at: https://github.com/abdora-ai/TRIUNE-Net

0.30

Optimal Transport Metric Learning for Feature Alignment in Partially Supervised Segmentation

eess.IV cs.AI ·2026-09-15 ·Dakini Mallam Garba, Salim Abdou Daoura
similarity 0.71
Abstract

Multi-organ segmentation is often challenged by partially annotated datasets and domain shifts across different imaging sources. To address these limitations, we propose a two-stage learning framework that efficiently leverages partial supervision. In the first stage, the model learns from available annotations to produce accurate segmentations of annotated organs, establishing robust feature representations. In the second stage, we introduce learnable organ prototypes and a Sinkhorn-triplet loss to enforce organ-wise feature consistency across datasets. This encourages latent embeddings of the same organ to remain close, while increasing separation between different organs, even when annotations are missing. Our approach achieves performance comparable to state-of-the-art methods on the BTCV dataset, while remaining computationally efficient. By explicitly aligning feature distributions rather than relying solely on pseudo-labels, the framework effectively mitigates domain shift, making it particularly suitable for medical image segmentation tasks with limited annotation resources.

0.06

SymmAdapt: Symmetrical Flow Matching for Source-Free Domain Adaptation in Medical Image Segmentation

cs.CV ·2026-08-23 ·Tal Grossman, Noa Cahan, Hayit Greenspan
published similarity 0.70
Abstract · Accepted at SASHIMI 2026, held in conjunction with MICCAI 2026. To appear in the Springer LNCS proceedings of the MICCAI 2026 Satellite Even…

Domain shift across imaging modalities and acquisition sites remains a significant barrier to the clinical deployment of segmentation models. Source-free unsupervised domain adaptation (SFUDA) addresses this by adapting a pretrained model to an unlabeled target domain without requiring access to sensitive source data. We introduce a novel SFUDA framework built on Symmetrical Flow Matching, a unified generative model that segments an input image and synthesizes a source-like image from a mask within the same learned flow. By initializing inference from a domain-agnostic Gaussian origin, the model preserves structural consistency across domains and grounds predictions in learned anatomy rather than shifted texture statistics. Our pipeline leverages this symmetry to generate reliable pseudo-labels and corresponding source-like synthetic images from unlabeled target data, creating a generative replay buffer that anchors source knowledge during a generative self-training stage that fine-tunes on a joint set of real target and synthetic source-like images. We evaluate on abdominal multi-organ and cardiac segmentation, covering cross-modality MRI<->CT shifts, and multi-site prostate segmentation. Our approach outperforms SFUDA baselines and is competitive with conventional UDA methods.

0.25

De-GAN - Dynamic Parameter Tuned GAN for 3D Medical Image Segmentation: A Step Towards Generalisation

cs.CV ·2026-09-15 ·Zoha Usama, Azadeh Alavi
code/data similarity 0.70
Abstract · error found

Brain tumor segmentation remains difficult because enhancing tumor (ET) has low contrast and overlaps surrounding tissue, while scanner and site variation causes domain shift. We propose DE-GAN, a contrast-enhancing conditional GAN that combines input-adaptive dynamic convolutions, style-aware feature mixing, and coordinate encoding to synthesize slice-adaptive FLAIR images. A label-guided, class-conditional target separates tumor-core (TC) and ET intensities while preserving anatomy. The generated FLAIR is concatenated with the original MR modalities and used to train a 3D U-Net. Across BraTS 2015, 2018, and 2019, DE-GAN improves segmentation over the baseline and static EnhGAN replacement on most reported TC/ET metrics, with the largest gains from retaining both original and enhanced FLAIR. Code and pretrained models are available at https://github.com/zkhansuri-ui/DE-GAN.

0.32

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

eess.IV cs.CV ·2026-09-20 ·Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
benchmarktheorycode/data similarity 0.70
Abstract · 22 pages, 7 figures, 4 tables. Code and data splits: https://github.com/ShubhamGajjar/vgg16-mca-unet

Automated brain tumor segmentation supports diagnosis, treatment planning, and monitoring of disease progression, but building models that generalize across heterogeneous tumors and limited annotated data remains difficult. We present VGG16-MCA UNet, a hybrid architecture pairing an ImageNet-pretrained VGG16 encoder with a decoder in which a Multi-Channel Attention (MCA) module recalibrates features after each skip-connection fusion, trained with the Focal Tversky loss to counter severe foreground-background imbalance. We evaluate the model as a 2D, FLAIR-only, whole-tumor segmenter on tumor-positive slices from two public datasets: the BraTS 2020 benchmark and the LGG MRI Segmentation dataset. Using 5-fold cross-validation and a single network formed by averaging the weights of the five fold models, the method attains an aggregate pixel-level Dice (F1) of 95.10% on our held-out BraTS 2020 split and 88.32% on LGG. These scores are computed over all test pixels pooled into a single confusion matrix rather than averaged per case, and are therefore not directly comparable to the per-case mean Dice used in the BraTS challenge protocol. All partitions were drawn over individual slices rather than over patients, so every patient contributes slices to both training and test; the figures above therefore measure interpolation within known patients and should be read as an upper bound rather than as generalization to new ones. The model segments a 256x256 slice in 66.32 ms on a single 6 GB NVIDIA RTX 2060, approximately 8 ms more than an equivalent VGG16-UNet without MCA. We release the split records and report the protocol in full, with the aim of providing a precisely specified and reproducible 2D FLAIR baseline.

0.23

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.69
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.13

CIRSeg: Coarse-to-Fine Intensity-Robust Liver Segmentation with Source-Free Continual Test-Time Adaptation

cs.CV ·2026-10-07 ·Ruoshi Xu, Mingqi Gao, Shengda Luo, Jingkun Chen
publishedcode/data similarity 0.69
Abstract · Accepted at the CARE 2026 Workshop at MICCAI 2026

Reliable liver segmentation in contrast-enhanced MRI is essential for quantitative hepatic assessment, treatment planning, and longitudinal disease monitoring. However, limited annotated data and scanner- or vendor-dependent intensity variations can cause overfitting and poor generalization to unseen acquisition domains. Moreover, simultaneously achieving robust global localization and precise boundary delineation remains challenging, while predictions may contain isolated false-positive regions outside the main liver component. To address these challenges, we propose CIRSeg, a coarse-to-fine, intensity-robust liver segmentation framework based on nnU-Netv2. CIRSeg combines 3D CutMix with stochastic intensity transfer using either Nyul augmentation or histogram matching to improve robustness to heterogeneous MRI intensities. Its cascaded architecture decouples low-resolution anatomical localization from full-resolution boundary refinement. At inference, source-free test-time adaptation based on confidence-filtered predictions and probability-prior regularization further improves robustness to out-of-distribution inputs. As a final deterministic post-processing step, largest connected component filtering removes isolated false-positive regions. On the CARE 2026 test set, CIRSeg achieves Dice scores of 97.13\% and 97.93\% on the in-domain and unseen-domain subsets, with corresponding HD95 values of 20.18 mm and 11.30 mm, respectively. These results demonstrate consistently accurate segmentation across both in-domain and unseen acquisition settings. The code is available at https://github.com/jingkunchen/MICCAI_CARE_2026

0.28