Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

Nazim-E-Alam

eess.IV cs.CV ·submitted 2026-09-04 13:39 UTC · v1

Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

Closest papers

Nearest neighbours by meaning across the whole index.

From Adults to Children: Benchmarking Foundation Models for Chest X-Ray Classification under Domain Shift

cs.CV ·2026-10-15 ·Sara Inácio, Hugo Proença, João C. Neves
publishedbenchmark similarity 0.75
Abstract · Accepted at WACV 2027

Foundation models have shown significant potential across diverse fields and have been applied to medical imaging, but their robustness across patient populations remains unclear. In this work, we investigate foundation models' ability to generalize from adult to pediatric chest X-ray classification. To the best of our knowledge, this is the first benchmark to compare multiple foundation models under a common adult-to-pediatric evaluation setting while also analyzing the effect of adaptation depth. We harmonize VinDr-CXR and PediCXR into a five-label classification task and evaluate six foundation models and two CNN baselines. All models are adapted using adult data only and tested in both the in-domain and pediatric domains using linear probing, partial fine-tuning, and full fine-tuning. The benchmark reveals a clear and consistent trend: all models suffer a substantial performance degradation when transferred from adult to pediatric data, with drops exceeding 10 percentage points. While Macro-AUROC values reach approximately 92% on the adult test set, performance decreases to around 78% on the pediatric domain. Another important finding is that increasing the depth of adaptation improves pediatric performance on average, although the effect varies across models. Moreover, strong in-domain performance does not necessarily indicate greater robustness to domain shift.

0.40

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.74
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

PCXR-Copilot: Device-aware pediatric chest radiographic analysis with segmentation, suppression, and edema-related cues

cs.CV ·2026-10-18 ·Xueyang Li, Alec Girten, Peng Zeng, Mingze Jiang, Shaoyang Huang +4 more
similarity 0.71
Abstract

Patients admitted to pediatric ICU and cardiac ICU often require intensive perioperative support and frequent chest radiography to monitor support devices, extravascular lung water, and body-wall edema. Radiographic interpretation and analysis is often difficult due to superimposed anatomic and iatrogenic structures that obscure clinically relevant signals. While deep learning can provide decision support, translation to pediatric radiographs is still limited by high device burden and scarcity of pediatric datasets with clinically grounded device annotations. To address this gap, we first introduce PediaDeviceSeg-1K, a curated dataset of 1,000 anterior-posterior radiographs of pediatric CICU patients with clinically grounded, fine-grained annotations of common ICU devices. To our best knowledge, this is the first publicly available pediatric CICU CXR resource with clinically grounded device annotations for device-focused benchmarking. Building on PediaDeviceSeg-1K, we further present PCXR-Copilot, a device-aware pipeline that outputs lung and device masks, optional device-suppressed views, and edema-related visualization maps and scalar indices. The full pipeline has been integrated and runs in real time within the TWIST platform at Boston Children's Hospital, demonstrating feasibility for real-world clinical deployment.

0.11

Pneumonia Detection on Chest X-Rays Derived from a U-Net Segmentation Model

eess.IV ·2026-10-15 ·Manasvini Singh
similarity 0.70
Abstract · 6 pages, 3 figures, 6 tables

Pneumonia killed more than 740,000 children under the age of five in 2019, and it can be difficult to recognize on chest radiographs (CXRs): opacities may be faint in early disease, may sit behind the equally bright heart shadow, and may resemble other lung conditions. Most deep learning systems treat pneumonia detection as a yes-or-no classification task. This paper asks whether a model trained on a harder task, segmenting pneumonia pixel by pixel, can be turned into an effective detector for the simpler task of deciding whether an image contains pneumonia at all. The hypothesis is that the detailed supervision of segmentation forces the network to learn where and what the disease looks like, producing a better detector than training for detection alone. A U-Net was trained to segment pneumonia on the RSNA Pneumonia Detection Challenge dataset of 26,684 radiographs, whose rectangular bounding boxes were converted into pixel masks. The data are heavily imbalanced: 22.5% of images are positive, and only 2.6% of pixels fall inside a box, so focal loss with α = 0.25 and γ = 2 and dropout were needed for the model to learn. On the harder segmentation task, the model reached a pixel-level F1 score of 0.45 on a held-out test set of 2,668 images. Applied to the simpler detection task, the same model reached a precision of 0.71, recall of 0.52, and F1 score of 0.60, with 91% specificity, and consistent scores on the development set. These results show that a segmentation-trained model transfers to detection while also showing where the suspected disease is. A direct comparison with a classifier trained only for detection on the same data is needed to confirm whether the segmentation-first approach is better, and is the main direction for future work.

0.18

Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case Study

cs.CV cs.LG ·2026-09-29 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.69
Abstract

Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even when it depends strongly on how the benchmark was evaluated. We study this problem on the widely used Kermany pediatric chest radiograph dataset using nine image classifiers and a controlled evaluation protocol. Under the same protocol, the eight pretrained backbones differ by only 0.026 AUROC. In contrast, changing whether the backbone is frozen or fine-tuned changes AUROC by 0.044 on average, and changing the decision threshold changes balanced accuracy by 0.090 on average. The official test split is also measurably different from the training pool: a partition classifier distinguishes them at AUC 0.697, rising to 0.898 for normal radiographs. Most strikingly, a classifier using only file properties, with no image anatomy, reaches 0.992 balanced accuracy within the training pool but falls to 0.496 on the official test split. Validation-fitted thresholds and calibration also transfer imperfectly. These results show that a high benchmark score can support different conclusions when the split, training policy, threshold, metric, calibration, and uncertainty are not communicated with it. We end with a seven-item reporting recommendation in which each item is tied to an effect measured in the study

0.11

A Comparative Study of GAN-Based Deep Learning Models for Pneumonia Detection in Chest X-Rays

cs.CV ·2026-09-05 ·Roshan Paudel, Aashish Ghimire, Pramod Acharya
similarity 0.69
Abstract

This study evaluates pneumonia classification in chest X-rays using VGG19, MobileNetV2, ResNet50, and a custom CNN, and explores Generative Adversarial Network (GAN)-based synthetic data augmentation. MobileNetV2 achieved the highest reported accuracy of 88% with balanced class-wise performance. The custom CNN achieved pneumonia recall of 92.67% and precision of 79.43%, highlighting a precision-recall trade-off. Accuracy, F1-score, precision, recall, confusion matrices, and training curves were used to assess performance. Synthetic pneumonia images were combined with real images to investigate whether augmentation could improve classification performance. In the reported VGG19 comparison, augmented-data training accuracy reached approximately 100%, while validation accuracy remained near 50%, below the real-data validation accuracy. This experiment therefore did not demonstrate a validation-performance benefit from GAN augmentation. The classifier comparison highlights differences in accuracy and pneumonia recall, while the augmentation experiment indicates the need for further evaluation of synthetic-image quality and training settings.

0.26

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.68
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

How well do routinely collected demographic and clinical variables aid point-of-care lung ultrasound TB classification

eess.IV cs.CVcs.LG ·2026-10-05 ·Joshua M. Jansen van Vüren, Christiaan M. Geldenhuys, Devendra S. Parihar, Véronique Suttels, Trevor Brokowski +5 more
published similarity 0.68
Abstract · Accepted: SATNAC, Drakensberg, South Africa, 2026

We consider the fusion of lung ultrasound images with routinely-collected clinical and demographic data for the purpose of automated tuberculosis (TB) screening using deep-learning. Such deep-learning based screening tools for TB could meaningfully support the health care system in Africa, where the burden of disease is severe and resources are constrained. Beginning with an established ResNet baseline for classification of lung ultrasound images, which achieves an area under the receiver operating characteristic (AUROC) curve of 0.91 [0.86,0.96] (95% CI), we consider the incorporation of the clinical and demographic data using three fusion approaches. We find that a simple average-based fusion of the output scores of separately-trained image and clinical data classifiers consistently matches or outperforms a more complex approach where the data is fused earlier and a combined classifier is trained. Fusing the image and the clinical classifiers in this way leads to a classifier with an overall AUROC of 0.95 [0.91,0.99] (specificity of 0.76 at sensitivity 0.93) which is an improvement of 4% absolute over the image-only baseline. We also find that greedy feature selection can be used to reduce the number of clinical and demographic inputs without sacrificing classification performance. Finally, when we differentiate between clinical and demographic data that are self-reported, that require some basic measurement or calculation, and that require a point-of-care (POC) test, we find the inclusion of the POC tests included in this study to be of minimal benefit to classification performance. We conclude that the incorporation of routinely-collected clinical and demographic data is a promising way to improve the performance of lung ultrasound based automatic classification.

0.25