CS Paper Radar

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha

cs.CV cs.AI ·submitted 2026-09-24 07:32 UTC · v1

Abstract

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

Comment
80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Closest papers

Nearest neighbours by meaning across the whole index.

CoRE: Relating Fine-Grained Chest X-ray Findings in Anatomical Context

eess.IV ·2026-10-22 ·Minjun Kim, Jong Hak Moon
similarity 0.76
Abstract · 18 pages, 3 figures

Chest X-ray interpretation depends on both the anatomical location of findings and their relationships with other abnormalities. However, relations defined over global finding labels do not explicitly distinguish the same finding across anatomical locations. We propose CoRE(Co-occurrence-guided Region Evidence), a framework that incorporates relationships among findings and anatomical context into fine-grained chest X-ray prediction. It groups anatomical region-finding labels by co-occurrence and uses these groups to guide shared representation learning through visual prompt tuning on a frozen vision transformer. The predictions are supplemented by an anatomically supervised region-evidence stream through region-matched logit residuals. Experiments on MIMIC-CXR with Chest ImaGenome annotations show that CoRE improves region-finding classification over standard and relation-aware prompt-based baselines. Quantitative evaluations on MS-CXR and the Chest ImaGenome gold standard show improved finding localization, supported by qualitative comparisons. CoRE also improves finding-level classification on mapped finding labels in external VinDr-CXR and CheXpert datasets without target-domain adaptation. These results demonstrate the value of jointly modeling finding relationships and anatomical context for fine-grained chest X-ray analysis.

0.21

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

cs.CV cs.AI ·2026-11-12 ·Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong +2 more
published similarity 0.75
Abstract · 17 pages, 6 figures, 11 tables

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

0.21

SentZero: An Enhanced Sentence-Centric Vision-Language Pretraining for Multi-Task Zero-Shot Chest X-Ray Analysis

cs.CV cs.AI ·2026-09-28 ·Hangyul Yoon, Hyungyung Lee, Edward Choi, Eunho Yang
similarity 0.72
Abstract

Vision-language (VL) pretraining using paired chest X-ray (CXR) images and radiology reports has shown strong potential for medical image understanding. However, existing methods often remain dependent on task-specific finetuning because radiology reports are lengthy, clinically dense, and difficult to align with simple zero-shot prompts. Recent sentence-level approaches partially address this limitation using clinical phrases extracted by large language models (LLMs), but they largely overlook the intrinsic characteristics of radiology discourse. In particular, limited positive-pair diversity constrains further gains, while clinically equivalent sentences frequently recur across patients, creating false negatives in contrastive learning. To address these issues, we propose SentZero, an enhanced sentence-centric VL pretraining framework for zero-shot, multi-task CXR analysis. SentZero introduces LLM-based abstract-level sentence structuring and mapping to expand positive-pair diversity, together with an additional loss term to mitigate false negatives. We further introduce sentence-conditioned residual modulation of visual embeddings, enabling visual features to adapt to the semantic characteristics of each input sentence. Across diverse downstream tasks and datasets, SentZero improves zero-shot generalization and outperforms prior multi-task zero-shot methods.

0.16

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.71
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.12

Look What the Probes Dragged In! Real-World Chest X-ray Shortcuts in MedCLIP

cs.CV cs.LG ·2026-08-12 ·Nikolette Pedersen, Regitze Sydendal, Veronika Cheplygina, Théo Sourget
publishedcode/data similarity 0.71
Abstract · 11 pages, 3 figure, poster presentation at the joint FAIMI, BRIDGE, and EPIMI workshop at MICCAI 2026 (Strasbourg, France) conference

Vision-language models, such as contrastive language-image pre-training (CLIP)-based approaches, have reached state-of-the-art (SOTA) results in medical artificial intelligence. However, recent work reveals that CLIP-based models remain vulnerable to shortcuts. We investigate how real-world shortcuts manifest across different layers of the medical CLIP-based model, MedCLIP, and its vision encoder, a frozen ResNet-50. We attach 17 linear classification probes to the intermediate layers of the ResNet-50 and train them on three different dataset configurations and targets: NIH-CXR14 (pneumothorax) and PadChest (cardiomegaly and pneumothorax). This setup allows us to observe model behaviour during evaluation using subgroup-based calibration and layer-wise confidence curves. We find that the final linear probes achieve a high AUROC but poor calibration in the models. The layer-wise confidence analyses suggest that shortcuts emerge at different depths. Patterns consistent with localised shortcuts, such as drains, appear at later layers, while patterns consistent with diffuse shortcuts, such as scanner-specific noise patterns, emerge earlier, aligning with previous work. Finally, we conduct a manual analysis of the images, which reveals data quality issues in both NIH-CXR14 and PadChest. Our findings underscore that even SOTA models remain vulnerable to shortcuts, and the need for high-quality and well-annotated datasets to draw solid conclusions. Code can be found on our GitHub: https://github.com/nikodice4/MedCLIP_shortcuts.

0.43

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

cs.CV ·2026-08-26 ·Juan Iñaki Larrea, Lucas Mansilla, Enzo Ferrante
published similarity 0.71
Abstract · Accepted at MIRASOL Workshop, MICCAI 2026. 10 pages, 3 figures

Foundation models are increasingly deployed for medical image analysis. However, under the inter-institutional distribution shift typical of deployment, their performance varies widely and cannot be known without target-domain labels, which are rarely available. This leaves a practical question unresolved: given several candidate foundational models and labeled-data from a source domain, which one to deploy in an unlabeled target domain? We propose a label-free selection criterion built on SUDO, a framework for evaluating clinical AI systems without ground-truth annotations. SUDO partitions the unlabeled target data by predicted probability and, for each region, measures a pseudo-label discrepancy reflecting class contamination; aggregated across regions, this yields a score (AURCC) requiring neither target annotation nor fine-tuning. We show that AURCC can be used to rank a variety of vision-language models (BioMedCLIP, CXR-CLIP, CheXzero, MedCLIP, MedImageInsight, CLIP) on chest X-ray classification across three inter-hospital shift scenarios, under zero-shot and MLP-probe regimes. The AURCC ranking recovers the ground-truth ranking with Spearman rho up to 0.943 (p<0.05). Against the natural baseline of ranking by held-out source accuracy, AURCC is competitive when the labeled source is large and yields a more accurate ranking once it is small; the regime of interest in resource-constrained settings.

0.19

Integrating Unimodal and Vision-Language Representations in Latent Space for Multi-Label Chest X-Ray Classification

cs.CV ·2026-08-31 ·Quang-Huy Tran, Duc-Tuan Ngo, Minh-Khoi Nguyen-Bui, Dang-Khoa Bui, Thanh-Trong Tran +2 more
code/data similarity 0.71
Abstract · 10 pages, 2 figures, 5 tables (main text); 12 pages, 1 figure, 13 tables (supplementary material)

Multi-label chest X-ray classification has attracted considerable attention in recent years, with the effective use of visual representations and clinical semantic knowledge playing an important role. This study proposes a framework that combines unimodal representations from RAD-DINO with vision--language representations from BioViL-T for the classification of 14 labels in the MIMIC-CXR-JPG dataset. The RAD-DINO and BioViL-T embeddings and their combined representation are refined separately in latent space before being normalized and fused across the three branches. In addition to improving classification performance, the study aims to clarify the role of each embedding source and the degree to which they complement one another. Experiments show that RAD-DINO outperforms BioViL-T when used independently, whereas early fusion further improves the results, indicating that the two embedding sources contain complementary information. The best-performing model achieves a mean AUROC of 0.840 and an mAP of 0.467. Ablation analysis shows that hybrid fusion provides consistent and statistically significant improvements over early fusion when each embedding source is refined in latent space, suggesting that fusion effectiveness depends on the quality of the representation supplied by each branch. However, the study has only been evaluated internally on MIMIC-CXR-JPG; its generalizability to data from other healthcare institutions therefore remains to be validated. The source code is available at: https://anonymous.4open.science/r/mimic-report-C210/.

0.40

CARET: Clinical Assertion-Aware Residual Calibration for Medical Image-Text Alignment

cs.CV cs.AI ·2026-11-13 ·Yifan Jin, Tao Liu
similarity 0.70
Abstract

Medical vision--language models align radiographs with free-text reports, but radiology language distinguishes explicit findings, negation, uncertainty, and omission. Treating these report states as interchangeable during feature adaptation can change image predictions without supporting visual evidence. We introduce CARET, a parameter-efficient image-side adaptation method that retains pretrained image and text encoders and uses paired positive and negative clinical statements to define a low-dimensional semantic correction space. A bounded residual adjusts image features along these directions, while assertion-aware supervision distinguishes explicitly present and absent findings from uncertain or unmentioned ones. At inference, the adapter requires only an image; textual references remain fixed. In zero-shot classification, CARET achieves 67.80\% accuracy on CheXpert 5$\times$200 and 65.20\% on RSNA. These scores exceed the published CLEFT-LoRA results by 1.06 and 0.27 percentage points, respectively. Comparisons to literature baselines are informative but not controlled for differences in pretraining and evaluation protocols. Ablations across eight components identify the four-state distinction and assertion objective as major contributors, with task-dependent effects for nonmention preservation and pair alignment.

0.19