CS Paper Radar

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong, Shreya Ghosh, Tom Gedeon

cs.CV cs.AI ·submitted 2026-11-12 07:05 UTC · v1
published

Abstract

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

Comment
17 pages, 6 figures, 11 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset

cs.CV cs.AI ·2026-09-23 ·Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang +4 more
benchmarkcode/data similarity 0.76
Abstract

X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on https://github.com/Event-AHU/Medical_Image_Analysis

0.32

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.75
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation

cs.CV ·2026-10-15 ·Shrish Shrinath Vaidya, Gowthamaan Palani, Minmini Selvam, Gokulraja Srinivasaraja, Ganapathy Krishnamurthi
published similarity 0.74
Abstract · The paper has been accepted at ECCV BISCUIT Workshop, 2026

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.

0.22

Diagnostic Loss: Asymmetric Supervision for Radiology Report Generation

cs.CV cs.LG ·2026-10-22 ·Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jarosław B. Ćwikła, Arkadiusz Sitek +2 more
code/datahot direction similarity 0.73
Abstract · 26 pages, 6 figures, 7 tables. Code available at https://github.com/gmum/DLoss

Automated radiology report generation requires models to do more than produce fluent clinical narratives: they must explicitly state supported diagnoses while avoiding unsupported ones. However, existing medical vision-language models (MedVLMs) are typically trained with token-level maximum likelihood objectives, which prioritize text agreement over diagnostically critical terms. As a result, models can miss key diagnoses and introduce wrong ones. We identify this as an objective misalignment between conventional language modeling and the asymmetric diagnostic requirements of radiology reporting. To encode these requirements, we introduce Diagnostic Loss (DLoss), a differentiable, architecture-agnostic objective that operates directly on decoder token probabilities. DLoss separately aggregates probability mass over vocabularies associated with diagnoses supported by the reference report and with unsupported alternatives. Using asymmetric pooling across token positions in the report, it encourages supported diagnoses to receive sufficient probability in at least one position while suppressing spurious probability spikes for unsupported diagnoses across all positions during training. The loss can be applied to existing 3D MedVLMs without modifying their vision backbones, language decoders, or inference procedures, and introduces no additional inference-time computation. We train and evaluate DLoss on 50,000 abdominal CT scans across several 3D MedVLM architectures on both in-distribution and out-of-distribution report-generation benchmarks. Across these settings, DLoss improves diagnostic faithfulness while maintaining competitive performance on conventional language-generation metrics, showing the value of asymmetric sequence-level supervision for radiology report generation. The code for DLoss is available at https://github.com/gmum/DLoss.

0.40

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.72
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

Cross-modal triage network: a multimodal deep learning framework for severity-based triage and visual explainability in chest radiographs

eess.IV cs.AIcs.CV ·2026-09-03 ·Zinah Ghulam, Richa Mittal, Eranga Ukwatta
benchmark similarity 0.72
Abstract

Purpose: Increased number of chest radiograph (CXR) scans create a triage bottleneck, queueing urgent examinations behind routine ones. Existing AI tools are predominantly unimodal binary classifiers lacking severity awareness, and multimodal systems are rarely benchmarked against expert radiologists. To this end, we developed a multimodal deep learning framework for joint severity triage, pathology detection, and native visual explanation. Approach: We propose the cross-modal triage network (CMTN), fusing a Swin Transformer V2 visual encoder with a PubMedBERT text encoder via gated cross-attention. The CMTN was trained on 34,639 image-text pairs (12,489 patients) from MIMIC-CXR-JPG, optimizing an ordinal focal loss for four-tier severity triage and binary cross-entropy for 14 pathologies. Beyond quantitative benchmarking, attention heatmaps were evaluated against a blinded expert radiologist in a two-phase clinical audit comparing model triage output to expert severity assessment (100 cases) and grading spatial-semantic concordance (116 heatmaps). Results: The CMTN achieved strong ordinal agreement with reference labels (quadratic weighted kappa [QWK] = 0.9341, 95\% CI: 0.9219 to 0.9449) and macro-AUROC of 0.9970 across 14 pathologies, with 34~ms latency, outperforming the state-of-the-art BioViL multimodal baseline (QWK = 0.7679). However, the blinded Phase I clinical audit revealed substantially lower agreement with genuine radiologist judgment (QWK = 0.1399). Phase II found 54.3\% of heatmaps achieved clinically acceptable spatial localization. Conclusions: The CMTN demonstrated an efficient multimodal architecture for CXR triage. The divergence between algorithmic and radiologist agreement demonstrates that benchmark performance against NLP-derived labels is insufficient, highlighting the need for radiologist-labeled ground truth before clinical deployment.

0.21

SentZero: An Enhanced Sentence-Centric Vision-Language Pretraining for Multi-Task Zero-Shot Chest X-Ray Analysis

cs.CV cs.AI ·2026-09-28 ·Hangyul Yoon, Hyungyung Lee, Edward Choi, Eunho Yang
similarity 0.72
Abstract

Vision-language (VL) pretraining using paired chest X-ray (CXR) images and radiology reports has shown strong potential for medical image understanding. However, existing methods often remain dependent on task-specific finetuning because radiology reports are lengthy, clinically dense, and difficult to align with simple zero-shot prompts. Recent sentence-level approaches partially address this limitation using clinical phrases extracted by large language models (LLMs), but they largely overlook the intrinsic characteristics of radiology discourse. In particular, limited positive-pair diversity constrains further gains, while clinically equivalent sentences frequently recur across patients, creating false negatives in contrastive learning. To address these issues, we propose SentZero, an enhanced sentence-centric VL pretraining framework for zero-shot, multi-task CXR analysis. SentZero introduces LLM-based abstract-level sentence structuring and mapping to expand positive-pair diversity, together with an additional loss term to mitigate false negatives. We further introduce sentence-conditioned residual modulation of visual embeddings, enabling visual features to adapt to the semantic characteristics of each input sentence. Across diverse downstream tasks and datasets, SentZero improves zero-shot generalization and outperforms prior multi-task zero-shot methods.

0.16

ICGF-CXRMate: Image-Conditioned Clinical Context Compression and Gated Fusion for Chest X-ray Report Generation

cs.CV ·2026-10-22 ·Vu Minh Tran, Thuc Huynh, Son Thanh Luu, Doanh C. Bui
similarity 0.72
Abstract

Auxiliary patient data can improve chest X-ray report generation, but directly concatenating heterogeneous clinical information with visual tokens produces long, variable-length decoder prompts and may expose the model to redundant or image-irrelevant context. We propose ICGF-CXRMate, an image-conditioned clinical context compression and gated fusion framework. Learnable queries are first conditioned on the current chest X-ray representations and then attend to the patient-data sequence, compressing it into a fixed number of clinical context tokens. Gated cross-attention selectively integrates these tokens into the visual stream, while the compressed tokens are retained in the decoder prompt as a direct clinical pathway. Experiments on linked MIMIC-CXR and MIMIC-IV-ED examinations show that ICGF-CXRMate improves report quality while reducing the average prompt length. In Stage~2, it improves RadGraph-F1 from 24.00 to 28.86, CXR-BERT similarity from 56.86 to 62.80, and BLEU-4 from 5.14 to 7.96 compared with CXRMate-ED, while reducing the average prompt length from 373.89 to 288.37 tokens, corresponding to a 22.9\% reduction. After self-critical sequence training, ICGF-CXRMate outperforms CXRMate-ED on six of eight report-quality metrics in Stage~3. Ablation studies confirm the complementary contributions of image-conditioned compression, gated fusion, and direct retention of the compressed clinical tokens.

0.17