CS Paper Radar

Cross-modal triage network: a multimodal deep learning framework for severity-based triage and visual explainability in chest radiographs

Zinah Ghulam, Richa Mittal, Eranga Ukwatta

eess.IV cs.AIcs.CV ·submitted 2026-09-03 18:19 UTC · v1
benchmark

Abstract

Purpose: Increased number of chest radiograph (CXR) scans create a triage bottleneck, queueing urgent examinations behind routine ones. Existing AI tools are predominantly unimodal binary classifiers lacking severity awareness, and multimodal systems are rarely benchmarked against expert radiologists. To this end, we developed a multimodal deep learning framework for joint severity triage, pathology detection, and native visual explanation. Approach: We propose the cross-modal triage network (CMTN), fusing a Swin Transformer V2 visual encoder with a PubMedBERT text encoder via gated cross-attention. The CMTN was trained on 34,639 image-text pairs (12,489 patients) from MIMIC-CXR-JPG, optimizing an ordinal focal loss for four-tier severity triage and binary cross-entropy for 14 pathologies. Beyond quantitative benchmarking, attention heatmaps were evaluated against a blinded expert radiologist in a two-phase clinical audit comparing model triage output to expert severity assessment (100 cases) and grading spatial-semantic concordance (116 heatmaps). Results: The CMTN achieved strong ordinal agreement with reference labels (quadratic weighted kappa [QWK] = 0.9341, 95\% CI: 0.9219 to 0.9449) and macro-AUROC of 0.9970 across 14 pathologies, with 34~ms latency, outperforming the state-of-the-art BioViL multimodal baseline (QWK = 0.7679). However, the blinded Phase I clinical audit revealed substantially lower agreement with genuine radiologist judgment (QWK = 0.1399). Phase II found 54.3\% of heatmaps achieved clinically acceptable spatial localization. Conclusions: The CMTN demonstrated an efficient multimodal architecture for CXR triage. The divergence between algorithmic and radiologist agreement demonstrates that benchmark performance against NLP-derived labels is insufficient, highlighting the need for radiologist-labeled ground truth before clinical deployment.

Closest papers

Nearest neighbours by meaning across the whole index.

CXR-CMFA: A Cross-Modal Feature Aggregation Network for Chest X-Ray Pathology Classification

cs.CV cs.AI ·2026-11-06 ·Talukder Hasnat Zadid, Jahin Sultana, Felipe Bochini Brisola, Kishore Roy, Mysha Rahman +2 more
benchmark similarity 0.82
Abstract

Chest X-ray (CXR) interpretation remains challenging because subtle pathology can be obscured by overlapping anatomy, image-quality variation, and limited visual evidence in isolated radiographs. Although image-only deep learning models provide useful baselines, they discard the complementary diagnostic context available in radiology reports, while large vision-language models can be computationally expensive for practical deployment. This paper presents CXR-CMFA, a lightweight cross-modal feature aggregation network for binary CXR pathology classification. The proposed framework combines a dual-stream visual encoder, using EfficientNet-B0 for global anatomical representation and DenseNet-121 for local pathological detail, with a TF-IDF-MLP report encoder. Two fusion modules integrate these modalities: the Dual-Modal Spatial Attention Module (DMSAM) uses the report embedding to gate global and local visual features, and the Cross-Modal Gated Feature Fusion (CGFF) module learns per-instance weights for visual and textual contributions. Experiments on the MIMIC-CXR benchmark, using the provided train, validation, and test splits, show that CXR-CMFA achieves 93.45% accuracy, 99.88% precision, 91.8% recall, 95.7% F1-score, and 99.19% AUC on the held-out test set. The model produces only four false positives among 984 normal test cases, supporting its suitability for high-specificity screening workflows. An ablation study further demonstrates a 22.47 percentage-point AUC improvement over the global-image-only variant, confirming the value of adaptive cross-modal fusion. These results indicate that compact report-conditioned fusion can provide strong discriminative performance without relying on large pretrained language models.

0.14

CheXFuse: Guided Differential Joint Attention Fusion for Robust Multimodal Chest X-Ray Classification in Data-Scarce Medical Settings

cs.CV cs.LG ·2026-10-19 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
publishedhighly cited similarity 0.76
Abstract · IEEE ICDM DMBIH 2026

A central challenge in multimodal learning is how to fuse modalities that differ substantially in predictive strength. When one modality provides a much stronger representation than another, indiscriminate cross-modal interaction can introduce weak, redundant, or unstable signals, limiting or even degrading performance relative to the strongest unimodal representation. To address this problem, we propose CheXFuse, a multimodal fusion framework based on Guided Differential Joint Attention (GuDJA). CheXFuse combines image and text token representations within a joint multimodal sequence, where learned token guidance emphasizes informative representations and differential attention reduces less useful attention responses. We evaluate CheXFuse on the Indiana University (IU) Chest X-ray dataset, using binary (normal vs. abnormal) classification as the downstream task. Experiments are conducted under both original-report and masked-report settings, with the latter serving as a controlled stress test under reduced textual informativeness. CheXFuse with GuDJA achieves the strongest mean overall performance across the evaluated baselines and ablations, reaching 95.73% accuracy, 95.79% F1-score, 96.54% recall, and 95.28% sensitivity at 95% specificity (Sens@95Spec) with original reports, and 95.58%, 95.60%, 95.60%, and 94.34%, respectively, under masked reports. These results suggest that GuDJA provides a promising fusion strategy under asymmetric or partially reduced modality informativeness.

0.49

Guided Co-Attention with Adaptive Gating for Multimodal Medical Data Fusion

cs.CV cs.LG ·2026-11-07 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
similarity 0.75
Abstract · IEEE BIBM 2026

Multimodal fusion requires not only exchanging information across modalities but also determining which representations should participate in the interaction and how complementary cross-modal views should be combined. We introduce Guided Co-Attention with Adaptive Gating, a fusion framework that integrates token-wise guidance, bidirectional cross-attention, and sample-specific fusion. The proposed method constructs two directional representations: an image-conditioned text representation, obtained by allowing textual tokens to query visual features, and a text-conditioned image representation formed in the reverse direction. Token-wise guidance modulates the representations before cross-attention, while an adaptive gate learns the relative contribution of the two resulting directional representations for each sample. We evaluate the approach using paired chest radiographs and radiology reports as an image-text test bed for binary (normal vs. abnormal) classification. The two cross-attention directions exhibit distinct performance characteristics, demonstrating that reversing the query and source modalities does not produce interchangeable representations. Ablation experiments further show that bidirectional interaction, adaptive gating, and token guidance provide complementary benefits. The proposed model achieves 96.05% accuracy, 96.10% F1-score, 98.37% AUC, 95.60% Sens@95Spec, and 96.51% Spec@95Sens, yielding the highest mean performance across all evaluated metrics. These findings support explicitly modeling interaction direction, token relevance, and sample-dependent integration when constructing multimodal representations.

0.16

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

cs.CV cs.AI ·2026-11-12 ·Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong +2 more
published similarity 0.72
Abstract · 17 pages, 6 figures, 11 tables

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

0.21

Acute Stroke Classification Using Asymmetric Data Standardization and Orthogonal-Focal Loss Optimized CNN-ViT Cross-Attention Fusion: A Multicenter External Validation Study

eess.IV cs.AI ·2026-10-25 ·Tansel Uyar
code/data similarity 0.71
Abstract · All research data has been uploaded to Zenodo (DOI: 10.5281/zenodo.22132268). The data presented in this study are available on request from…

Background/Objectives: Rapid differentiation of ischemic and hemorrhagic stroke subtypes is vital for acute management. Although current deep learning models achieve high single-dataset accuracy, they suffer from "shortcut learning" and domain shift in external validation. This study proposes a hierarchical computer-aided diagnostic (CAD) system mimicking emergency triage. Methods: We introduce a 3-channel Radiology-Focused Preprocessing pipeline that feeds radiological Hounsfield Unit (HU) windows into Convolutional Neural Network (CNN) and Vision Transformer (ViT) backbones via asymmetric formats (.mat and .png). The architecture utilizes a novel joint cross-attention fusion network optimized by an Integrated Orthogonal-Focal Loss. Results: Our system achieved a 95.48% F1-score on the internal stroke dataset. However, multi-center external validation (AISD, BHSD, PhysioNet) using a Mask Anchor filter revealed a drop to the 58-62% range, exposing the "internal validation illusion" caused by hardware noise. Critically, models exhibited high precision (77%) but low sensitivity (57%) for ischemic stroke, proving prone to hemorrhage overdiagnosis. Multi-seed variance analysis demonstrated that the DenseNet201+ViT backbone yielded the lowest deviation (0.59) and highest stability, making it the most reliable architecture for real-world clinical integration. Conclusions: To overcome diagnostic challenges, future research must focus on multimodal architectures that combine 3D volumetric extraction with clinical data.

0.33

MedCORE: Criteria-Grounded Clinical Reasoning for Interpretable Medical Image Diagnosis

cs.CV cs.AI ·2026-10-06 ·Asim Khan, Samee Ullah Khan, Dwarikanath Mahapatra
similarity 0.70
Abstract · 16 pages, 4 figures, conference

Clinical diagnosis is inherently a structured reasoning process, yet existing deep learning models often bypass this structure by mapping image features directly to disease labels without explicitly interrogating the morphological and textural criteria that clinicians systematically evaluate. This limits diagnostic transparency and may compromise safe clinical deployment. We present MedCORE (Medical Criteria-Oriented Reasoning and Evidence), a structured diagnostic framework that operationalizes clinical reasoning within a vision-language architecture. For each input image, MedCORE decomposes the diagnostic process into clinically defined criteria, spatially localizes each criterion to diagnostically relevant image regions, encodes evidence through multi-scale representations that capture macro-structural and micro-textural pathological characteristics, and refines criterion representations using a Graph Attention Network that explicitly models inter-criteria dependencies. Criterion representations are further aligned with clinical text descriptors, reinforced through class-wise visual prototypes, and aggregated using uncertainty-calibrated weighting that proportionally discounts low-confidence diagnostic evidence. MedCORE is validated across three clinically heterogeneous imaging modalities, including dermoscopic lesion classification on ISIC 2018, breast ultrasound lesion characterization on BUSI, and diabetic retinopathy grading on IDRiD. Quantitatively, MedCORE achieves 89.2% accuracy, 85.7% macro-F1, and 96.4% AUC on ISIC 2018; 96.1% accuracy, 95.2% macro-F1, and 98.4% AUC on BUSI; and 84.3% accuracy, 80.2% macro-F1, and 92.8% AUC on IDRiD. These results demonstrate consistent improvements over strong CNN, transformer, biomedical vision-language, concept-based, and prototype-based baselines.

0.20

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.70
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

SentZero: An Enhanced Sentence-Centric Vision-Language Pretraining for Multi-Task Zero-Shot Chest X-Ray Analysis

cs.CV cs.AI ·2026-09-28 ·Hangyul Yoon, Hyungyung Lee, Edward Choi, Eunho Yang
similarity 0.69
Abstract

Vision-language (VL) pretraining using paired chest X-ray (CXR) images and radiology reports has shown strong potential for medical image understanding. However, existing methods often remain dependent on task-specific finetuning because radiology reports are lengthy, clinically dense, and difficult to align with simple zero-shot prompts. Recent sentence-level approaches partially address this limitation using clinical phrases extracted by large language models (LLMs), but they largely overlook the intrinsic characteristics of radiology discourse. In particular, limited positive-pair diversity constrains further gains, while clinically equivalent sentences frequently recur across patients, creating false negatives in contrastive learning. To address these issues, we propose SentZero, an enhanced sentence-centric VL pretraining framework for zero-shot, multi-task CXR analysis. SentZero introduces LLM-based abstract-level sentence structuring and mapping to expand positive-pair diversity, together with an additional loss term to mitigate false negatives. We further introduce sentence-conditioned residual modulation of visual embeddings, enabling visual features to adapt to the semantic characteristics of each input sentence. Across diverse downstream tasks and datasets, SentZero improves zero-shot generalization and outperforms prior multi-task zero-shot methods.

0.16