CS Paper Radar

CARET: Clinical Assertion-Aware Residual Calibration for Medical Image-Text Alignment

Yifan Jin, Tao Liu

cs.CV cs.AI ·submitted 2026-11-13 16:16 UTC · v1

Abstract

Medical vision--language models align radiographs with free-text reports, but radiology language distinguishes explicit findings, negation, uncertainty, and omission. Treating these report states as interchangeable during feature adaptation can change image predictions without supporting visual evidence. We introduce CARET, a parameter-efficient image-side adaptation method that retains pretrained image and text encoders and uses paired positive and negative clinical statements to define a low-dimensional semantic correction space. A bounded residual adjusts image features along these directions, while assertion-aware supervision distinguishes explicitly present and absent findings from uncertain or unmentioned ones. At inference, the adapter requires only an image; textual references remain fixed. In zero-shot classification, CARET achieves 67.80\% accuracy on CheXpert 5$\times$200 and 65.20\% on RSNA. These scores exceed the published CLEFT-LoRA results by 1.06 and 0.27 percentage points, respectively. Comparisons to literature baselines are informative but not controlled for differences in pretraining and evaluation protocols. Ablations across eight components identify the four-state distinction and assertion objective as major contributors, with task-dependent effects for nonmention preservation and pair alignment.

Closest papers

Nearest neighbours by meaning across the whole index.

Rethinking Contrastive Targets in Radiology Language-Image Pretraining

cs.CV cs.LG ·2026-11-18 ·Yunhe Gao, Ashwin Kumar, Jiaming Liu, Chong Wang, Maya Varma +6 more
publishedbenchmark similarity 0.73
Abstract · NeurIPS 2026

CLIP-style contrastive image-text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither of which is systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn from large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that explains both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: text is treated as positive whenever its clinical assertions agree with the image, with no architecture changes. Beyond benchmark improvements, CorLIP largely removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction transfers from chest X-ray to 3D CT modalities.

0.26

PLRS-IC: A Dual-Calibration Framework for Chest X-Ray Vision-Language Alignment

cs.CV ·2026-09-30 ·Qixing Zhao, Jinpeng Li
benchmark similarity 0.72
Abstract · 9 pages, 4 figures, 5 tables

Fine-grained vision-language alignment in chest radiography enables zero-shot classification, grounding, and segmentation without task-specific annotations. However, this alignment is fundamentally hindered by two intertwined sources of ambiguity: projection-induced visual mismatch and patient-agnostic semantic overlap. First, at the local feature level, frontal and lateral radiographs exhibit distinct appearances for the same clinical finding, rendering a shared patch-text similarity geometry inherently suboptimal. Compounding this visual ambiguity is a semantic mismatch during global contrastive optimization, where instance-level objectives penalize cross-patient pairs as strict negatives even when they share identical positive clinical concepts. To address this dual ambiguity, we propose PLRS-IC, a unified dual-calibration framework for chest X-ray representation learning. At the local alignment stage, Projection-Conditioned Low-Rank Residual Similarity (PLRS) dynamically adapts patch-text matching to projection-specific manifolds using a bounded, parameter-efficient low-rank residual. At the global optimization stage, Information-Content-Calibrated Soft False-Negative Suppression (IC-SFNS) leverages a corpus-derived information-theoretic prior to soften the penalty of semantically overlapping negatives without altering original contrastive assignments. Extensive experiments across nine public zero-shot benchmark settings demonstrate that our framework yields consistent improvements in classification, grounding, and segmentation, validating the necessity of dual-calibration in medical vision-language pre-training.

0.17

What Do Medical Vision-Language Models Learn in Radiology? Transfer, Alignment, and Source-Proxy Leakage Under Distribution Shift

cs.CV cs.AI ·2026-08-26 ·Ayoub Louaye Bouaziz, Lokmane Chebouba, Yassine Himeur
similarity 0.71
Abstract

Medical vision-language models (VLMs) can appear reliable in-domain while failing when acquisition domain, paired supervision, or evaluation protocol changes. We study this failure mode as a representation-level blind spot relevant to epistemic intelligence, without claiming a formal estimator of epistemic uncertainty. Using NIH ChestXray14 and CheXpert, we first isolate source-only cross-dataset visual transfer from unsupervised domain-adaptation diagnostics. Using PadChest and OpenI, we then evaluate multimodal alignment under strict pair-index retrieval and quantify metadata-derived source-proxy information retained in frozen embeddings. Self-supervised visual initialization improves NIH-to-CheXpert transfer over supervised ImageNet initialization in matched ResNet-18 comparisons, whereas adversarial adaptation is useful only in a narrow regime and becomes unstable as adversarial pressure increases. Multimodal exact-pair retrieval remains low under external OpenI stress testing, and source-proxy information remains recoverable from learned representations. Qualitative nearest-neighbor and Grad-CAM analyses show clinically plausible cross-dataset structure and thoracic attention patterns in many cases, while device-heavy and false-positive cases remain ambiguous. Auxiliary architecture checks are task-dependent and do not support a universal backbone ranking. Overall, the study shows that apparent competence under a single protocol can conceal transfer, alignment, and shortcut-related failure modes, motivating stress-tested evaluation of medical VLMs under distribution shift.

0.21

Gated Prototype Transfer for Zero-Support Medical Vision Language Model

cs.CV cs.AI ·2026-10-20 ·Sumaiya Fazal, Rizwan Qureshi, Laleh Behjat, Samira Ebrahimi Kahou
publishedcode/data similarity 0.70
Abstract · Accepted to Symposium on Model Accountability, Sustainability and Healthcare 2026

Realistic few-shot adaptation of medical vision-language models (VLMs) can leave low-prevalence classes without any labeled support. The training-free SS- Text+ solver remains operational in this setting, but its zero-support prototypes receive no visual adaptation and fall back to a purely textual class prototype. We in- troduce Gated Knowledge-Guided Prototype Transfer (GProtoT), a pre-repulsion module that transfers supported-class visual residuals to missing classes using VLM similarity and an ontology-based clinical distance. A validation-free evidence gate scales transfer based on semantic relevance and residual agreement, thereby limiting unsupported extrapolation. In 50 paired realistic one-shot trials on MESSIDOR with FLAIR features, severe and proliferative diabetic retinopathy were absent from every support set. Relative to SS-Text+, gated ProtoT improved missing-class recall by 5.23 points, average class accuracy by 1.37 points, and the missing/supported recall harmonic mean by 1.83 points. It reduced negative- transfer frequency from 46-48% for ungated transfer to 2%, while at the cost of reductions of 1.20 percentage points in supported-class recall and 0.45 percentage points in top-1 accuracy. These results indicate that evidence-based gating provides a safety mechanism for the knowledge source. GProtoT is based on SS- Text+ and requires no gradients, validation data, or additional model inference, of- fering a low-compute path toward accountable adaptation under incomplete clini- cal supervision. Code is available: https://github.com/sumaiyaafridi/GProtoT

0.41

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.70
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

Lumen: Parameter-Efficient Alignment of Pretrained Vision and Language Encoders for Zero-Shot Computational Pathology

cs.CV ·2026-09-15 ·Kiarash Tajbakhsh, Abdelrahman Faqieh, Michael Jopiti, Javier Garcia-Baroja, Philipp Zens +7 more
similarity 0.70
Abstract

Pathology vision-language models are commonly built by pretraining or fine-tuning large encoders on paired image-caption data. We asked whether a pathology vision-language model can instead be assembled by parameter-efficient alignment of frozen unimodal foundation models, leaving their pretrained representations untouched. Here we present Lumen, which aligns frozen Virchow2 and BioMedBERT backbones using rank-4 adapters and projection heads, training only 0.40% of the total parameters on the public QUILT-1M corpus. Across nine public zero-shot patch benchmarks, Lumen achieved the highest mean chance-corrected balanced accuracy, 0.546 versus 0.461 for the strongest baseline (paired difference 0.086, 95% CI 0.042-0.136). On lymph-node metastasis detection, Lumen reached an AUROC of 0.964 (95% CI 0.956-0.971) on 4,214 held-out internal slides and 0.955 (95% CI 0.942-0.966) on 2,368 slides across nine external cohorts and six organs. At the internally calibrated threshold, it outperformed all vision-language baselines, with a balanced accuracy of 0.909 (95% CI 0.896-0.923) internally and 0.915 (95% CI 0.902-0.929) externally. Lumen performed competitively across the evaluations, with the exception of cross-modal retrieval, where it ranked third behind CONCH and PathGen-L/14. Fully fine-tuning both encoders gave Lumen no consistent benefit over low-rank adaptation, although it improved retrieval. Aligning frozen unimodal foundation models therefore yields strong and transferable performance at patch and slide level while training only a small fraction of the parameters.

0.15

Expandable Modality Experts for Medical Vision-Language Learning

cs.CV ·2026-10-21 ·DM BAPPY, Eunsu Kim, Hanjoo Lee, Sung Hak Lee, Sangjeong Ahn
benchmark similarity 0.68
Abstract · 11 pages (main text), 42 pages (supplementary material), 2 main figures. Submitted to ICLR 2027

Learning across medical imaging modalities requires making use of images without paired text and accommodating new domains while retaining existing representations. We propose a medical vision-language technique built around an expandable bank of modality experts. Its Multiway Transformer combines shared visual computation with deterministically routed feed-forward experts and a separate text pathway. A modality-aware visual tokenizer supplies targets for masked pretraining on 19.4 million unpaired image rows across seven modalities; contrastive alignment then uses 3.23 million image-text pairs. Additional fundus and optical coherence tomography experts learn from paired data while the original image and text embedding paths remain frozen. With a ViT-Large backbone, the proposed technique achieves the best or tied-best result in 24 of 25 benchmark settings across nine modalities: 10 of 11 zero-shot classification benchmarks, all 10 linear probes, and all four retrieval benchmarks. Mean balanced accuracy is 0.674 for zero-shot classification and 0.856 for linear probing, and mean bidirectional retrieval recall is 20.70%. A separate three-seed sequential experiment with matched adaptation data yields fundus and OCT retrieval gains of 14.95 and 9.31 percentage points, with no measured loss on preceding fundus or pathology tasks. The preservation argument requires unchanged existing computation paths and inference conditions, and feature-identity checks verify retention on evaluated inputs. The proposed technique provides a modular approach to learning and expanding medical vision-language representations.

0.21

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.68
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.12