CS Paper Radar

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

Jinrui Wu, Yun Peng

cs.CV cs.AI ·submitted 2026-11-18 07:52 UTC · v1

Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

Closest papers

Nearest neighbours by meaning across the whole index.

Rethinking Contrastive Targets in Radiology Language-Image Pretraining

cs.CV cs.LG ·2026-11-18 ·Yunhe Gao, Ashwin Kumar, Jiaming Liu, Chong Wang, Maya Varma +6 more
publishedbenchmark similarity 0.74
Abstract · NeurIPS 2026

CLIP-style contrastive image-text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither of which is systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn from large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that explains both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: text is treated as positive whenever its clinical assertions agree with the image, with no architecture changes. Beyond benchmark improvements, CorLIP largely removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction transfers from chest X-ray to 3D CT modalities.

0.26

Retrieval-Grounded Multi-View Reasoning for Clinically Reliable Radiology Report Generation

cs.CV ·2026-11-03 ·Wanshu Fan, Zeyu Wang, Zheng Tong, Qi Ai, Wencai Weng +6 more
similarity 0.73
Abstract

Chest radiograph report generation is hampered by retrieved reports that resemble the current image but are clinically inconsistent with it, and by diagnostic-label imbalance. We present RG-MVR, a retrieval-grounded framework comprising Retrieval-Augmented Evidence Grounding, which combines dense memory summaries with visually gated sparse retrieved evidence; Adaptive Multi-view Evidential Reasoning, which weights image, memory, and retrieved evidence per case; and a Clinical Prompt Learner, which models finding mention separately from positive, negative, or uncertain status. On MIMIC-CXR, RG-MVR achieved a clinical-label F1 of 0.483 and a BLEU-4 of 0.118 (IU X-ray: 0.202 and 0.110). In an exploratory external cohort of 22 examinations, clinical-label agreement declined markedly (F1, 0.071) and unsupported statements remained common, although physicians found fewer unsupported temporal comparisons (9 vs. 20 cases) and device-related statements (7 vs. 15) than with the baseline. Evidence-aware retrieval and structured diagnostic prompting may reduce specific reporting errors, but broader external validation is required.

0.22

CoRE: Relating Fine-Grained Chest X-ray Findings in Anatomical Context

eess.IV ·2026-10-22 ·Minjun Kim, Jong Hak Moon
similarity 0.73
Abstract · 18 pages, 3 figures

Chest X-ray interpretation depends on both the anatomical location of findings and their relationships with other abnormalities. However, relations defined over global finding labels do not explicitly distinguish the same finding across anatomical locations. We propose CoRE(Co-occurrence-guided Region Evidence), a framework that incorporates relationships among findings and anatomical context into fine-grained chest X-ray prediction. It groups anatomical region-finding labels by co-occurrence and uses these groups to guide shared representation learning through visual prompt tuning on a frozen vision transformer. The predictions are supplemented by an anatomically supervised region-evidence stream through region-matched logit residuals. Experiments on MIMIC-CXR with Chest ImaGenome annotations show that CoRE improves region-finding classification over standard and relation-aware prompt-based baselines. Quantitative evaluations on MS-CXR and the Chest ImaGenome gold standard show improved finding localization, supported by qualitative comparisons. CoRE also improves finding-level classification on mapped finding labels in external VinDr-CXR and CheXpert datasets without target-domain adaptation. These results demonstrate the value of jointly modeling finding relationships and anatomical context for fine-grained chest X-ray analysis.

0.21

Rethinking weakly supervised localization on chest radiographs: position nulls, protocol dependence, and PACE

cs.CV cs.LG ·2026-09-29 ·Shixin Qiu
benchmark similarity 0.73
Abstract

Weakly supervised localization on chest radiographs is reported as a single overlap accuracy, and those numbers are not comparable across papers. We measure what one contains. Against position-null controls that keep a readout's own box and move only its position, class activation mapping and its gradient-weighted variant beat the null on two to four of seven annotated findings on ChestX-ray14 and two of eight on CheXlocalize. The null is beatable: three board-certified radiologists clear it on four to seven. Three rarely stated choices each move a result by more than most reported method effects: the results regime, the extraction threshold, and the mask-to-box rule, whose cost is predicted by how fragmented the thresholded mask is. Predicted box area alone reverses a paired comparison. These measurements produced PACE, for \emph{population anomaly and class evidence}, which multiplies the finding identity from the label-trained head by the spatial evidence from a frozen radiograph backbone that never sees a pathology label. It is the case study that made the protocol dependence visible, and we report its costs beside its gain: in an exploratory matched-area analysis it improves strict-overlap accuracy on both corpora and beats a label-derived second map, but it is the least faithful of the three readouts to the classifier's causal map, its advantage depends on the box rule, and, this benchmark releasing no localization validation set, every design choice behind it was made on the boxes it is scored on. Its one clean transfer beats one baseline and loses to the other.

0.27

Carving Radiology Reports at Their Evidential Joints: Anatomical Region Sets as Generation Units

cs.CL cs.CV ·2026-10-21 ·Jinwei Yang, Junhao Chen, Jianwei Zhao, Zhonghan Xu, Hong Cheng +1 more
similarity 0.72
Abstract · 28 pages, 4 figures

Organizing radiology reports into independently generated units offers a way to generate fine-grained clinical content and bind it to visual evidence. However, existing methods typically adopt generation-unit structures not directly specified in natural reports or their annotations, introducing additional modeling compromises. We propose RadCarve, which instead defines generation units directly from the anatomical region sets in existing statement-region correspondences, unifying unit formation with visual evidence selection. RadCarve's planner uses composition-specialized query banks to jointly predict unit existence and region composition from the image, iteratively refining both with regional evidence aggregated according to current membership predictions. The generator independently produces each unit's text conditioned on the joint visual evidence of its predicted region set. Compared with strong baselines, RadCarve improves CXRFEScore by 9.4% in unit generation given region sets and achieves 2.4 times the end-to-end binding F1. It also achieves leading report-generation results on Chest ImaGenome and PadChest-GR, using fewer than one-sixth as many parameters as large-scale baselines.

0.28

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.71
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

PLRS-IC: A Dual-Calibration Framework for Chest X-Ray Vision-Language Alignment

cs.CV ·2026-09-30 ·Qixing Zhao, Jinpeng Li
benchmark similarity 0.71
Abstract · 9 pages, 4 figures, 5 tables

Fine-grained vision-language alignment in chest radiography enables zero-shot classification, grounding, and segmentation without task-specific annotations. However, this alignment is fundamentally hindered by two intertwined sources of ambiguity: projection-induced visual mismatch and patient-agnostic semantic overlap. First, at the local feature level, frontal and lateral radiographs exhibit distinct appearances for the same clinical finding, rendering a shared patch-text similarity geometry inherently suboptimal. Compounding this visual ambiguity is a semantic mismatch during global contrastive optimization, where instance-level objectives penalize cross-patient pairs as strict negatives even when they share identical positive clinical concepts. To address this dual ambiguity, we propose PLRS-IC, a unified dual-calibration framework for chest X-ray representation learning. At the local alignment stage, Projection-Conditioned Low-Rank Residual Similarity (PLRS) dynamically adapts patch-text matching to projection-specific manifolds using a bounded, parameter-efficient low-rank residual. At the global optimization stage, Information-Content-Calibrated Soft False-Negative Suppression (IC-SFNS) leverages a corpus-derived information-theoretic prior to soften the penalty of semantically overlapping negatives without altering original contrastive assignments. Extensive experiments across nine public zero-shot benchmark settings demonstrate that our framework yields consistent improvements in classification, grounding, and segmentation, validating the necessity of dual-calibration in medical vision-language pre-training.

0.17

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

cs.CV cs.AI ·2026-08-28 ·Huseyin Umut Isik, Mehmet Alp Ozaydin, Sila Kurugol, Şeyda Ertekin
publishedcode/data similarity 0.71
Abstract · Accepted to the Thoracic Image Analysis (TIA) Workshop at MICCAI 2026

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

0.62