CS Paper Radar

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew

cs.CV ·submitted 2026-08-31 08:54 UTC · v1
code/data

Abstract

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

Comment
34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Closest papers

Nearest neighbours by meaning across the whole index.

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.74
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06

CXR-CMFA: A Cross-Modal Feature Aggregation Network for Chest X-Ray Pathology Classification

cs.CV cs.AI ·2026-11-06 ·Talukder Hasnat Zadid, Jahin Sultana, Felipe Bochini Brisola, Kishore Roy, Mysha Rahman +2 more
benchmark similarity 0.72
Abstract

Chest X-ray (CXR) interpretation remains challenging because subtle pathology can be obscured by overlapping anatomy, image-quality variation, and limited visual evidence in isolated radiographs. Although image-only deep learning models provide useful baselines, they discard the complementary diagnostic context available in radiology reports, while large vision-language models can be computationally expensive for practical deployment. This paper presents CXR-CMFA, a lightweight cross-modal feature aggregation network for binary CXR pathology classification. The proposed framework combines a dual-stream visual encoder, using EfficientNet-B0 for global anatomical representation and DenseNet-121 for local pathological detail, with a TF-IDF-MLP report encoder. Two fusion modules integrate these modalities: the Dual-Modal Spatial Attention Module (DMSAM) uses the report embedding to gate global and local visual features, and the Cross-Modal Gated Feature Fusion (CGFF) module learns per-instance weights for visual and textual contributions. Experiments on the MIMIC-CXR benchmark, using the provided train, validation, and test splits, show that CXR-CMFA achieves 93.45% accuracy, 99.88% precision, 91.8% recall, 95.7% F1-score, and 99.19% AUC on the held-out test set. The model produces only four false positives among 984 normal test cases, supporting its suitability for high-specificity screening workflows. An ablation study further demonstrates a 22.47 percentage-point AUC improvement over the global-image-only variant, confirming the value of adaptive cross-modal fusion. These results indicate that compact report-conditioned fusion can provide strong discriminative performance without relying on large pretrained language models.

0.14

Pneumonia Detection on Chest X-Rays Derived from a U-Net Segmentation Model

eess.IV ·2026-10-15 ·Manasvini Singh
similarity 0.72
Abstract · 6 pages, 3 figures, 6 tables

Pneumonia killed more than 740,000 children under the age of five in 2019, and it can be difficult to recognize on chest radiographs (CXRs): opacities may be faint in early disease, may sit behind the equally bright heart shadow, and may resemble other lung conditions. Most deep learning systems treat pneumonia detection as a yes-or-no classification task. This paper asks whether a model trained on a harder task, segmenting pneumonia pixel by pixel, can be turned into an effective detector for the simpler task of deciding whether an image contains pneumonia at all. The hypothesis is that the detailed supervision of segmentation forces the network to learn where and what the disease looks like, producing a better detector than training for detection alone. A U-Net was trained to segment pneumonia on the RSNA Pneumonia Detection Challenge dataset of 26,684 radiographs, whose rectangular bounding boxes were converted into pixel masks. The data are heavily imbalanced: 22.5% of images are positive, and only 2.6% of pixels fall inside a box, so focal loss with α = 0.25 and γ = 2 and dropout were needed for the model to learn. On the harder segmentation task, the model reached a pixel-level F1 score of 0.45 on a held-out test set of 2,668 images. Applied to the simpler detection task, the same model reached a precision of 0.71, recall of 0.52, and F1 score of 0.60, with 91% specificity, and consistent scores on the development set. These results show that a segmentation-trained model transfers to detection while also showing where the suspected disease is. A direct comparison with a classifier trained only for detection on the same data is needed to confirm whether the segmentation-first approach is better, and is the main direction for future work.

0.18

From Adults to Children: Benchmarking Foundation Models for Chest X-Ray Classification under Domain Shift

cs.CV ·2026-10-15 ·Sara Inácio, Hugo Proença, João C. Neves
publishedbenchmark similarity 0.72
Abstract · Accepted at WACV 2027

Foundation models have shown significant potential across diverse fields and have been applied to medical imaging, but their robustness across patient populations remains unclear. In this work, we investigate foundation models' ability to generalize from adult to pediatric chest X-ray classification. To the best of our knowledge, this is the first benchmark to compare multiple foundation models under a common adult-to-pediatric evaluation setting while also analyzing the effect of adaptation depth. We harmonize VinDr-CXR and PediCXR into a five-label classification task and evaluate six foundation models and two CNN baselines. All models are adapted using adult data only and tested in both the in-domain and pediatric domains using linear probing, partial fine-tuning, and full fine-tuning. The benchmark reveals a clear and consistent trend: all models suffer a substantial performance degradation when transferred from adult to pediatric data, with drops exceeding 10 percentage points. While Macro-AUROC values reach approximately 92% on the adult test set, performance decreases to around 78% on the pediatric domain. Another important finding is that increasing the depth of adaptation improves pediatric performance on average, although the effect varies across models. Moreover, strong in-domain performance does not necessarily indicate greater robustness to domain shift.

0.40

Extending the Horizon of Early Diagnosis: Lung Cancer Prediction with Vision Transformers

cs.CV ·2026-08-21 ·Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson +9 more
similarity 0.70
Abstract

Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage malignancies can be subtle on chest X-rays, creating challenges for radiologists. This study evaluates Vision Transformers (ViTs) for predicting lung cancer one to two years before clinical diagnosis. We analyzed 259,361 chest X-rays from 91,020 imaging studies at the Jamaica Plains VA Hospital in Boston, MA. The dataset showed extreme class imbalance, approximately 1:150 cancer to non-cancer, which was addressed using hybrid under- and over-sampling and class-weighted loss optimization. Three ViT configurations were evaluated: a model trained from scratch, an ImageNet-pretrained model, and a Corona-pretrained model fine-tuned on the lung cancer dataset. Transfer learning improved performance, with pretrained models exceeding the scratch baseline by 6-10 percentage points in AUC and about 10-12 percent in balanced accuracy. ImageNet-pretrained models showed the most stable overall performance, while Corona-pretrained models achieved higher sensitivity in some settings but greater variability. Moderate resampling ratios, including 1:1 undersampling and 1.5:2 oversampling, provided favorable trade-offs between sensitivity, precision, and computational efficiency, reducing runtime by up to 70 percent without major performance loss. These findings demonstrate the potential of ViTs for early lung cancer risk prediction from routine chest X-rays. Although performance remains below clinical deployment thresholds, the results support further development of ViT-based triage systems to flag high-risk patients for earlier evaluation.

0.09

CoRE: Relating Fine-Grained Chest X-ray Findings in Anatomical Context

eess.IV ·2026-10-22 ·Minjun Kim, Jong Hak Moon
similarity 0.69
Abstract · 18 pages, 3 figures

Chest X-ray interpretation depends on both the anatomical location of findings and their relationships with other abnormalities. However, relations defined over global finding labels do not explicitly distinguish the same finding across anatomical locations. We propose CoRE(Co-occurrence-guided Region Evidence), a framework that incorporates relationships among findings and anatomical context into fine-grained chest X-ray prediction. It groups anatomical region-finding labels by co-occurrence and uses these groups to guide shared representation learning through visual prompt tuning on a frozen vision transformer. The predictions are supplemented by an anatomically supervised region-evidence stream through region-matched logit residuals. Experiments on MIMIC-CXR with Chest ImaGenome annotations show that CoRE improves region-finding classification over standard and relation-aware prompt-based baselines. Quantitative evaluations on MS-CXR and the Chest ImaGenome gold standard show improved finding localization, supported by qualitative comparisons. CoRE also improves finding-level classification on mapped finding labels in external VinDr-CXR and CheXpert datasets without target-domain adaptation. These results demonstrate the value of jointly modeling finding relationships and anatomical context for fine-grained chest X-ray analysis.

0.21

How well do routinely collected demographic and clinical variables aid point-of-care lung ultrasound TB classification

eess.IV cs.CVcs.LG ·2026-10-05 ·Joshua M. Jansen van Vüren, Christiaan M. Geldenhuys, Devendra S. Parihar, Véronique Suttels, Trevor Brokowski +5 more
published similarity 0.68
Abstract · Accepted: SATNAC, Drakensberg, South Africa, 2026

We consider the fusion of lung ultrasound images with routinely-collected clinical and demographic data for the purpose of automated tuberculosis (TB) screening using deep-learning. Such deep-learning based screening tools for TB could meaningfully support the health care system in Africa, where the burden of disease is severe and resources are constrained. Beginning with an established ResNet baseline for classification of lung ultrasound images, which achieves an area under the receiver operating characteristic (AUROC) curve of 0.91 [0.86,0.96] (95% CI), we consider the incorporation of the clinical and demographic data using three fusion approaches. We find that a simple average-based fusion of the output scores of separately-trained image and clinical data classifiers consistently matches or outperforms a more complex approach where the data is fused earlier and a combined classifier is trained. Fusing the image and the clinical classifiers in this way leads to a classifier with an overall AUROC of 0.95 [0.91,0.99] (specificity of 0.76 at sensitivity 0.93) which is an improvement of 4% absolute over the image-only baseline. We also find that greedy feature selection can be used to reduce the number of clinical and demographic inputs without sacrificing classification performance. Finally, when we differentiate between clinical and demographic data that are self-reported, that require some basic measurement or calculation, and that require a point-of-care (POC) test, we find the inclusion of the POC tests included in this study to be of minimal benefit to classification performance. We conclude that the incorporation of routinely-collected clinical and demographic data is a promising way to improve the performance of lung ultrasound based automatic classification.

0.25

Physiologically Informed Digital Auscultation for Pneumonia Detection in Long-term Care Residents

cs.SD cs.CVcs.LGeess.AS+1 ·2026-09-23 ·Nicholas Rasmussen, Oleg Zaslavsky, Zih-Ling Wang, Hongyu Yu, Joelle Fathi +3 more
similarity 0.68
Abstract · Manuscript has been submitted to NPJ Digital Medicine

Pneumonia is difficult to diagnose in older long-term care residents; multimorbidity and atypical presentations obscure signs, motivating operationally efficient objective testing. We analyzed multi-channel digital stethoscope recordings from 185 Japanese residents (73 pneumonia, 112 symptomatic without), using radiologist-confirmed chest X-rays and clinician diagnoses as supervisory signals that train convolutional neural networks, multimodal fusion, and channel-based variants with time-domain Grad-CAM interpretability. Models were evaluated with repeated patient-level cross-validation showing models with X-ray supervision outperformed clinician supervision (F1 0.729, accuracy 0.783 vs. F1 0.637, accuracy 0.711). Additionally, a three-channel selection protocol maintained performance (F1 0.736; accuracy 0.803), with two mid-thoracic sites ranking highest and Grad-CAM attention overlapping adventitious sounds. These findings indicate automated multi-channel lung-sound analysis can aid long-term care pneumonia diagnosis, with X-ray supervision being more reliable than clinical, and fewer channels preserving performance while lowering acquisition times.

0.14