CS Paper Radar

Extending the Horizon of Early Diagnosis: Lung Cancer Prediction with Vision Transformers

Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson, Rowena Yip, Myvizhi Esai Selvan, Zeynep H. Gumus, Claudia Henschke, Robert J. Klein, Providencia Morales, Samuel M Aguayo, Ioana Danciu, Mayanka Chandrashekar

cs.CV ·submitted 2026-08-21 19:19 UTC · v1

Abstract

Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage malignancies can be subtle on chest X-rays, creating challenges for radiologists. This study evaluates Vision Transformers (ViTs) for predicting lung cancer one to two years before clinical diagnosis. We analyzed 259,361 chest X-rays from 91,020 imaging studies at the Jamaica Plains VA Hospital in Boston, MA. The dataset showed extreme class imbalance, approximately 1:150 cancer to non-cancer, which was addressed using hybrid under- and over-sampling and class-weighted loss optimization. Three ViT configurations were evaluated: a model trained from scratch, an ImageNet-pretrained model, and a Corona-pretrained model fine-tuned on the lung cancer dataset. Transfer learning improved performance, with pretrained models exceeding the scratch baseline by 6-10 percentage points in AUC and about 10-12 percent in balanced accuracy. ImageNet-pretrained models showed the most stable overall performance, while Corona-pretrained models achieved higher sensitivity in some settings but greater variability. Moderate resampling ratios, including 1:1 undersampling and 1.5:2 oversampling, provided favorable trade-offs between sensitivity, precision, and computational efficiency, reducing runtime by up to 70 percent without major performance loss. These findings demonstrate the potential of ViTs for early lung cancer risk prediction from routine chest X-rays. Although performance remains below clinical deployment thresholds, the results support further development of ViT-based triage systems to flag high-risk patients for earlier evaluation.

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.70
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/data similarity 0.69
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38

Uncertainty-driven training for three-dimensional calibrated lung nodule classification

eess.IV cs.CV ·2026-09-17 ·Giuseppe Tripodi, Alessandro De Rosis, Saleh Rezaeiravesh
publishedbenchmark similarity 0.69
Abstract

In this work, we present an uncertainty-driven training framework for three-dimensional computed tomography (CT) lung nodule classification, where validation-based uncertainty estimates guide loss reweighting to enhance predictive performance and probability calibration. Two Uncertainty Quantification (UQ) methods are considered: Monte Carlo Dropout (MCD) and Evidential Deep Learning (EDL). Both provide per-class uncertainty estimates that modulate the loss and encourage focus on hard or unreliable classes. The framework is evaluated with ResNet, DenseNet, EfficientNet, Vision Transformer (ViT), and Swin Transformer backbones on two datasets: the clinical LIDC-IDRI cohort and the NoduleMNIST3D benchmark. Uncertainty-driven training achieves classification performance similar to conventional training while substantially improving calibration, with an expected calibration error (ECE) reduced by up to 65% on LIDC-IDRI. EDL attains competitive performance on shallower architectures with single-pass inference, whereas MCD is more robust on deeper networks. Analysis across architectural families reveals that uncertainty-driven training benefits convolutional backbones more consistently than transformer-based architectures: EDL in particular degrades on ViT, suggesting that the Dirichlet evidence parameterisation may interact unfavourably with attention-based architectures at lower input resolutions. A posteriori temperature scaling proves highly effective across all configurations, indicating that a simple scalar calibration can be competitive even without explicit uncertainty-aware training. Our results indicate that integrating UQ into the training loop can significantly improve probabilistic calibration and support more trustworthy deployment of three-dimensional medical imaging models.

0.19

Comprehensive Benchmarking of Deep Learning Architectures for Lung Cancer Histopathology

cs.CV cs.AI ·2026-08-16 ·Hadi Hasan, Safaa Salman, Lama Sleem, Ralph Mouawad, Ali Chehab
benchmark similarity 0.69
Abstract · 8 pages

Lung cancer remains the leading cause of cancer-related mortality worldwide, while histopathological diagnosis is often affected by inter-observer variability and the substantial workload associated with manual slide examination. Although deep learning has shown considerable potential in computational pathology, comprehensive benchmarks that integrate tissue classification and region segmentation within a unified analytical framework remain limited. This study presents a two-stage deep learning framework for multi-class tissue classification and pixel-level histopathological region segmentation, accompanied by a systematic comparison of state-of-the-art architectures at each stage. For tissue classification, six models, a custom convolutional neural network, VGG16, DenseNet, MobileNetV3, a custom Vision Transformer, and YOLO11, are evaluated on a combined dataset of 39,000 images derived from LC25000 and LungHist700. The models distinguish between adenocarcinoma, squamous cell carcinoma, and normal lung tissue. YOLO11 achieves the best classification performance, with an accuracy of 98.38%, a five-fold cross-validation accuracy of 98.21 +/- 0.35%, and a macro F1-score of 0.98. For region segmentation, U-Net, ResNet-encoder U-Net, DeepLabV3+, and YOLO11-seg are evaluated using the GlaS gland segmentation benchmark. DeepLabV3+ obtains the highest Intersection over Union of 0.80 and a Dice score of 0.89, while YOLO11-seg achieves a comparable Intersection over Union of 0.79 using approximately 14x fewer parameters. The best-performing classification and segmentation models are subsequently integrated into an end-to-end framework, providing an accurate, computationally efficient, and reproducible baseline for automated histopathological image analysis.

0.40

Impact of Pretraining Length, Model Size, and Annotation Budget on Downstream Clinical Tasks of Foundation Models in Radiotherapy

cs.CV ·2026-11-17 ·Alejandro Cortina Uribe, Sidsel Højklint Poulsen, Ivan Richter Vogelius, Jens Petersen
code/data similarity 0.68
Abstract · 9 pages, 5 figures, 2 tables. Supplementary Material included

Cone-beam CT (CBCT) scans acquired during radiotherapy capture changes such as tumor shrinkage and radiation-induced tissue changes, offering great potential for foundation models that help monitor individual treatment responses. However, to our knowledge, no large-scale pretrained models for radiotherapy CBCT exist, and evaluating modeling choices is difficult since downstream tasks are not known in advance. We examine how pretraining length, model size, and finetuning strategy relate to downstream clinical performance, and how metrics tracked during pretraining correlate with it. We pretrain vision transformer encoders with masked image modeling on about 150,000 raw 3D radiotherapy CBCT scans, tracking representation quality via validation loss, effective rank, and linear probing. Downstream tasks are classification of feeding tube presence ($n=51,135$ CBCTs, $1,562$ patients) and clinical characteristics (T-, N-stage, sex, age, tumor site; $n=1,278$ patients) in head and neck cancer. We compare low-rank adaptation (LoRA) and full finetuning against no pretraining, varying annotated dataset size. Pretext validation loss was the most consistent predictor of downstream performance; effective rank and linear probing were also associated, but not consistently across model sizes and finetuning methods. LoRA performed comparably to full finetuning while training only 0.5-2.5% of the parameters. Fully finetuned models consistently outperformed models without pretraining across all sizes, with AUROC 0.91-0.97 vs. 0.58-0.85 for feeding tube classification and 0.99-1.00 vs. 0.71-0.97 for sex classification. Model size had only a small, inconsistent effect, suggesting smaller models suffice at lower computational cost. Code and pretrained models (non-commercial license): https://github.com/alexCortinaU/RT-CBCT_SSL

0.48

From Adults to Children: Benchmarking Foundation Models for Chest X-Ray Classification under Domain Shift

cs.CV ·2026-10-15 ·Sara Inácio, Hugo Proença, João C. Neves
publishedbenchmark similarity 0.68
Abstract · Accepted at WACV 2027

Foundation models have shown significant potential across diverse fields and have been applied to medical imaging, but their robustness across patient populations remains unclear. In this work, we investigate foundation models' ability to generalize from adult to pediatric chest X-ray classification. To the best of our knowledge, this is the first benchmark to compare multiple foundation models under a common adult-to-pediatric evaluation setting while also analyzing the effect of adaptation depth. We harmonize VinDr-CXR and PediCXR into a five-label classification task and evaluate six foundation models and two CNN baselines. All models are adapted using adult data only and tested in both the in-domain and pediatric domains using linear probing, partial fine-tuning, and full fine-tuning. The benchmark reveals a clear and consistent trend: all models suffer a substantial performance degradation when transferred from adult to pediatric data, with drops exceeding 10 percentage points. While Macro-AUROC values reach approximately 92% on the adult test set, performance decreases to around 78% on the pediatric domain. Another important finding is that increasing the depth of adaptation improves pediatric performance on average, although the effect varies across models. Moreover, strong in-domain performance does not necessarily indicate greater robustness to domain shift.

0.40

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling

cs.CV ·2026-09-02 ·Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede +3 more
positioncode/data similarity 0.67
Abstract

There is growing interest in adopting CLIP-style vision--language model (VLM) pretraining for mammography. However, models that directly employ the standard CLIP architecture and training objective exhibit limited zero-shot performance in clinically important tasks such as cancer, finding-type, and BI-RADS predictions. We argue that this underwhelming performance is due to neglecting two characteristics of mammography data: (1) its high-res nature, and (2) homogeneity of radiology reports, largely driven by a predominance of negative/benign findings on examinations. We propose TopKSigLIP, a VLM designed to address these two limitations through a novel architecture and learning objectives. Instead of downscaling high-res mammography images to satisfy GPU memory constraints, TopKSigLIP introduces TopK-Patch module that learns to sample a sparse set of high-res patches likely to contain lesions, sidestepping the resolution--batch size tradeoff of VLM training. The sampled patch locations additionally serve as a built-in localization tool. To address report homogeneity, we replace the contrastive loss, which falsely repels semantically similar pairs, with a Sup-sigmoid loss. Sup-sigmoid loss extends the sigmoid loss from SigLIP with soft labels derived from structured data. TopKSigLIP outperforms existing open-source mammography and general medical VLMs on both internal and external benchmarks on density assessment, BI-RADS classification, finding subtyping, and cancer prediction under zero-shot evaluation. TopKSigLIP remains competitive under linear probing despite using a significantly smaller vision encoder and smaller training batches than baselines. The TopK-Patch module additionally achieves superior lesion localization over post-hoc Grad-CAM. Code and weights are made public:https://github.com/Youngseok0001/TopKSigLIP.

0.30

Interpretable Deep Learning Models for Breast Cancer Diagnosis Using Medical Imaging

cs.CV cs.AI ·2026-10-27 ·Sami Alnawali, Muhammad Atif Saeed, Abdul Hadi, Azka Atiq, Akhtar Jamil +1 more
benchmark similarity 0.67
Abstract · 37 page, 45 Figures

Deep learning shows promise for breast cancer diagnosis, but limited interpretability hinders clinical adoption. We benchmark ten ImageNet-pretrained models (ResNet50, VGG19, InceptionV3, DenseNet121, Xception, MobileNetV2, EfficientNet, ConvNeXt, ViT, and Swin Transformer) for benign-versus-malignant classification on the BreakHis histopathology dataset using a patient-level split, and explain their predictions with Grad-CAM, LIME, Integrated Gradients, and LRP. DenseNet121 performed best, with 99.4% test accuracy and an AUC-ROC of 0.999, and significantly outperformed all other models (p < 0.001). Transformer-based models trailed the CNNs. The explanations consistently highlighted nuclei-rich and glandular regions of diagnostic relevance. Combining transfer learning with explainable AI can thus yield accurate, interpretable tools for breast cancer diagnosis.

0.19