CS Paper Radar

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling

Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede, Mohammadreza Chavoshi, Judy Gichoya, Hari Trivedi

cs.CV ·submitted 2026-09-02 18:59 UTC · v2
positioncode/data

Abstract

There is growing interest in adopting CLIP-style vision--language model (VLM) pretraining for mammography. However, models that directly employ the standard CLIP architecture and training objective exhibit limited zero-shot performance in clinically important tasks such as cancer, finding-type, and BI-RADS predictions. We argue that this underwhelming performance is due to neglecting two characteristics of mammography data: (1) its high-res nature, and (2) homogeneity of radiology reports, largely driven by a predominance of negative/benign findings on examinations. We propose TopKSigLIP, a VLM designed to address these two limitations through a novel architecture and learning objectives. Instead of downscaling high-res mammography images to satisfy GPU memory constraints, TopKSigLIP introduces TopK-Patch module that learns to sample a sparse set of high-res patches likely to contain lesions, sidestepping the resolution--batch size tradeoff of VLM training. The sampled patch locations additionally serve as a built-in localization tool. To address report homogeneity, we replace the contrastive loss, which falsely repels semantically similar pairs, with a Sup-sigmoid loss. Sup-sigmoid loss extends the sigmoid loss from SigLIP with soft labels derived from structured data. TopKSigLIP outperforms existing open-source mammography and general medical VLMs on both internal and external benchmarks on density assessment, BI-RADS classification, finding subtyping, and cancer prediction under zero-shot evaluation. TopKSigLIP remains competitive under linear probing despite using a significantly smaller vision encoder and smaller training batches than baselines. The TopK-Patch module additionally achieves superior lesion localization over post-hoc Grad-CAM. Code and weights are made public:https://github.com/Youngseok0001/TopKSigLIP.

Closest papers

Nearest neighbours by meaning across the whole index.

Healthy Counterfactual Generation via Diffusion Inpainting for Mammography Classification

cs.CV ·2026-10-08 ·Inês Cruchinho Garcia, Mariana Mourão, Francisco Maria Calisto, Carlos Santiago, Jacinto Nascimento
publishedcode/data similarity 0.70
Abstract · Accepted at MICCAI Workshop Deep-Brea3th 2026

False negatives remain a critical limitation of computer-aided diagnosis (CAD) systems for breast cancer screening due to delayed detection and treatment. To address this issue, we propose a counterfactual data augmentation strategy that generates healthy mammograms by "erasing" lesions from anomalous images, thereby enriching the training distribution. We train a Denoising Diffusion Probabilistic Model on BI-RADS 1 (healthy) mammograms and use a RePaint-based sampling strategy to inpaint realistic normal tissue within annotated lesion bounding boxes. The resulting healthy counterfactuals replace annotated lesion regions with realistic healthy tissue while preserving patient-specific anatomical structure, as supported by similarity metrics between real and generated images. Image realism was further assessed by radiologists and found to be consistent with the original dataset quality. We evaluate counterfactual augmentation across four representative classifier architectures: a convolutional neural network (ConvNeXt), a vision transformer (ViT), a vision-language model pre-trained on mammogram-report pairs (Mammo-CLIP) and a multi-scale attention-based multiple-instance learning framework (FPN-MIL). Experiments conducted on the VinDr-Mammo dataset show improvements in sensitivity across all architectures, particularly at 80\% fixed specificity, contributing towards more reliable CAD systems for breast cancer. Code is available at: https://github.com/ines03garcia/diffusion-based-counterfactual-generation.

0.33

Modern Backbones Improve Multi-task DETR for Mammography Classification and Lesion Localization

cs.CV cs.AI ·2026-08-10 ·Dinh Tan Nguyen, Quang-Hien Kha, Le-Hoang Nguyen, Minh-Toan Dinh, Xuan-Huy Nguyen +6 more
similarity 0.69
Abstract · Medical Imaging with Deep Learning 2026 - Short Paper Track

Joint exam-level prediction and candidate-region localization may improve the usefulness of AI support in mammography. We study this setting using a multi-task DETR framework, where shared representations support both image-level malignancy prediction and lesion localization, and evaluate its performance on OPTIMAM and a biopsy-confirmed SGM1k cohort. Across both datasets, modern backbones consistently outperformed older ResNet-style features, with ConvNeXtV2 and DINOv3 giving the strongest overall results, whereas MambaVision was less competitive. On OPTIMAM, ConvNeXtV2 achieved the best overall performance, reaching 97.96% AUC, 99.89% sensitivity, 25.08% mAP@.5, and 74.38% recall@.25. On SGM1k, DINOv3 gave the strongest overall results, with 90.97% AUC, 86.28% sensitivity, 82.00% specificity, 27.04% mAP@.5, and 77.32% recall@.25. These findings suggest that backbone quality is a critical factor in effective multi-task mammography, with ConvNeXtV2 emerging as a particularly strong and well-matched CNN backbone for mammography in this framework.

0.04

Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

cs.CV ·2026-11-17 ·Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel +1 more
publishedcode/data similarity 0.68
Abstract · Accepted at WACV 2027. Code: https://github.com/StanfordMIMI/data-curation-3d-medical-vlm

Training 3D vision-language models (VLMs) on large medical imaging datasets collected across institutions is constrained by data quality. Vast, uncurated pools of image-report pairs are characterized by redundancy, class imbalance, and cross-institutional heterogeneity. We address this challenge of data curation for improving 3D VLM pretraining by proposing an offline, training-free, reference-guided data curation recipe. Our approach leverages a small, high-quality reference set to independently extract quality signals for each modality of a large, uncurated pool and merges them through a rank-aggregation step into a single ranking that guides sample selection. We validate this method on datasets comprising 35k 3D abdominal CT volume-report pairs from two institutions and 58k 2D chest X-ray image-report pairs. On 3D CT, using our reference-guided data curation strategy, our curated model matches the zero-shot disease classification performance of a state-of-the-art baseline (Merlin) while using $3.3\times$ less training data and a reference set of 5k samples. On 2D chest X-rays, our method yields a curated model that matches or exceeds the zero-shot disease classification performance of a model trained on the full pool while using up to $10\times$ less training data and a reference set of only 74 samples. Ablations show that the selection is stable under resampling of the reference, that smaller reference sets still outperform random sampling, and that label rebalancing does not improve performance. To support reproducibility, we release our code.

0.52

MammoSeek: A Mammography Agent with selective zooming for grounded reports

cs.CV ·2026-11-04 ·Haoyan Ding, Qian Wang, Lixia Wang, Debiao Li
similarity 0.68
Abstract · 5 pages, 2 figures

Radiologists read a screening mammogram by first forming a global impression of the four views and then selectively magnifying suspicious regions before assigning a BI-RADS assessment. MLLMs, in contrast, see the whole image at a fixed, reduced resolution, which makes sub-millimeter calcifications invisible, and they perform close to chance on mammography. Therefore, we present MammoSeek, a mammography agent that reproduces this reading process. After forming an impression of each breast, the agent performs selective zooming: it decides by itself which detector candidates deserve a closer look and inspects only those on full-resolution views. Guided by a BI-RADS assessment skill, it then assigns a category and generates a localized, lexicon-structured report for each breast; its assessment is combined with image-model scores in a decision layer to decide recall. On an internal (EMBED) and an external (VinDr-Mammo) dataset, \ours reaches exam-level AUCs of 0.824 and 0.818, far above other MLLMs, mammography agent and CNN classifiers. Selective zooming also outperforms both no zooming and forced zooming in localization, structured-report F1 and recall decisions at low cost.

0.29

MammoMix: Leveraging Mixture of Experts for Robust Mammogram Breast Detection

cs.CV ·2026-08-11 ·Dinh Tan Nguyen, Hoang Quan Dang, Chen Zhang, Sai Ho Ling
published similarity 0.68
Abstract · Australasian Joint Conference on Artificial Intelligence 2025

Breast lesion detection in mammography remains a challenging task due to variations in image quality, lesion appearance, and population demographics across datasets. While current object detectors such as YOLO and DETR achieve strong results on individual datasets, their performance often degrades when trained on or applied across heterogeneous sources. To address this, we propose MammoMix, a novel framework based on Mixture-of-Experts (MoE) paradigm for robust and generalizable lesion detection. In MammoMix, each expert model is trained on a specific domain, allowing it to specialize in distinct characteristics of its source data. A gating mechanism adaptively weighs contributions from each expert based on input image, combining their outputs to enable domain-adaptive inference. To improve reliability, we further incorporate a calibration module, MoCAE, which adjusts confidence scores to reflect true predictive uncertainty. We evaluate MammoMix on 3 public mammography datasets: CSAW, DDSM, and DMID, covering diverse clinical settings. Results show that MammoMix outperforms baseline detectors in both average precision and reliability, particularly on datasets with greater variability. Our findings demonstrate that expert specialization and calibrated ensemble fusion significantly enhance model generalization and robustness. MammoMix offers a promising step toward dependable AI-assisted breast cancer screening across real-world clinical domains.

0.52

Extending the Horizon of Early Diagnosis: Lung Cancer Prediction with Vision Transformers

cs.CV ·2026-08-21 ·Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson +9 more
similarity 0.67
Abstract

Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage malignancies can be subtle on chest X-rays, creating challenges for radiologists. This study evaluates Vision Transformers (ViTs) for predicting lung cancer one to two years before clinical diagnosis. We analyzed 259,361 chest X-rays from 91,020 imaging studies at the Jamaica Plains VA Hospital in Boston, MA. The dataset showed extreme class imbalance, approximately 1:150 cancer to non-cancer, which was addressed using hybrid under- and over-sampling and class-weighted loss optimization. Three ViT configurations were evaluated: a model trained from scratch, an ImageNet-pretrained model, and a Corona-pretrained model fine-tuned on the lung cancer dataset. Transfer learning improved performance, with pretrained models exceeding the scratch baseline by 6-10 percentage points in AUC and about 10-12 percent in balanced accuracy. ImageNet-pretrained models showed the most stable overall performance, while Corona-pretrained models achieved higher sensitivity in some settings but greater variability. Moderate resampling ratios, including 1:1 undersampling and 1.5:2 oversampling, provided favorable trade-offs between sensitivity, precision, and computational efficiency, reducing runtime by up to 70 percent without major performance loss. These findings demonstrate the potential of ViTs for early lung cancer risk prediction from routine chest X-rays. Although performance remains below clinical deployment thresholds, the results support further development of ViT-based triage systems to flag high-risk patients for earlier evaluation.

0.09

NoduleFlow: Automatic 3D Lung Nodule Detection and Segmentation

cs.CV ·2026-10-12 ·Giulia Romoli, Filippo Ruffini, Francesco Di Feola, Valerio Guarrasi, Matteo Tortora +1 more
similarity 0.66
Abstract

Low dose Computed Tomography (CT) is the standard imaging modality for lung cancer screening. On CT scans, lung cancer typically manifests as pulmonary nodules, whose manual identification is time-consuming and prone to observer variability, image quality limitations, and suboptimal reading conditions. Moreover, subtle temporal changes are often difficult to quantify reliably in CT scans from the same patient across follow-up examinations. Deep learning-based approaches for the automatic detection and segmentation of lung nodules have demonstrated improved accuracy and efficiency. However, most existing approaches provide only coarse region-of-interest localisation, rely on prior lesion annotations or human supervision, or treat detection and segmentation as separate tasks. In this work, we present NoduleFlow, a framework for lung nodule detection, classification, and segmentation directly from series of CT volumes. Our proposal consists of four interconnected modules and operates in an automated manner at inference time, without requiring prior lesion annotations, manual initialisation, or region-of-interest pre-selection. We further investigate whether nodule localization benefits from the propagation of candidate regions across follow-up scans through inter-scan registration fields, as opposed to conventional independent per-scan analysis. The generalisability of the framework is systematically evaluated across four independent datasets. The results underscore the potential of automated pipelines for lung nodule analysis in screening and diagnostic settings.

0.14

Weakly-supervised Kidney Tumor Classification from CT Scans with Multi-Instance Learning and Anatomical Filtering

cs.CV ·2026-09-07 ·Joonas Ariva, Dmytro Fishman
similarity 0.66
Abstract · 16 pages, 3 figures

Deep learning models for CT scan analysis are often limited by the scarcity of precise pixel-level annotations, which require significant radiologist effort to produce. Training on scan-level labels alone reduces annotation requirements but introduces challenges: low supervision ratios and large input volumes make models prone to overfitting and shortcut learning. In this work, we investigate two complementary methods to address these challenges: multi-instance learning (MIL) and anatomical filtering. MIL divides CT volumes into 2D slice instances, enabling efficient 2D architectures with ImageNet pretraining rather than computationally demanding 3D models. Anatomical filtering uses Compass, our self-supervised body part regression model, to crop scans to pathology-relevant subregions without requiring segmentation masks. We evaluate two MIL frameworks - Attention-based MIL (ABMIL) and FocusMIL - on kidney tumor classification across one internal dataset (TUH) and two external datasets (KiTS23 and TCGA-KiRC). Our best models achieve F1 = 0.83 on the internal test set using only scan-level labels. We further show that anatomical filtering with the Compass model is critical for the out-of-distribution generalization of embedding-based ABMIL, while instance-based FocusMIL demonstrates greater inherent robustness to distribution shift. While evaluated on kidney tumors, we consider this a proof-of-concept for a broader weakly supervised CT classification pipeline applicable to other organs and pathologies.

0.16