CS Paper Radar

MammoSeek: A Mammography Agent with selective zooming for grounded reports

Haoyan Ding, Qian Wang, Lixia Wang, Debiao Li

cs.CV ·submitted 2026-11-04 22:23 UTC · v1

Abstract

Radiologists read a screening mammogram by first forming a global impression of the four views and then selectively magnifying suspicious regions before assigning a BI-RADS assessment. MLLMs, in contrast, see the whole image at a fixed, reduced resolution, which makes sub-millimeter calcifications invisible, and they perform close to chance on mammography. Therefore, we present MammoSeek, a mammography agent that reproduces this reading process. After forming an impression of each breast, the agent performs selective zooming: it decides by itself which detector candidates deserve a closer look and inspects only those on full-resolution views. Guided by a BI-RADS assessment skill, it then assigns a category and generates a localized, lexicon-structured report for each breast; its assessment is combined with image-model scores in a decision layer to decide recall. On an internal (EMBED) and an external (VinDr-Mammo) dataset, \ours reaches exam-level AUCs of 0.824 and 0.818, far above other MLLMs, mammography agent and CNN classifiers. Selective zooming also outperforms both no zooming and forced zooming in localization, structured-report F1 and recall decisions at low cost.

Comment
5 pages, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

MammoClaw: Towards Skill-Evolving Agent Harness for Breast Cancer Mammography Analysis

eess.IV cs.CV ·2026-09-25 ·Krishna Kanth Nakka
published similarity 0.70
Abstract · Accepted at Deep Breast Imaging Workshop, MICCAI 2026

In this work, we explore MammoClaw, a training-free agent framework that leverages frozen MLLMs for mammography analysis. To support agentic investigation, we equip the agent with lightweight mammography-specific tools for targeted image analysis, including ROI, paired-view, and contralateral-breast examination. MammoClaw iteratively gathers evidence through these tools, while skill evolution enables non-parametric adaptation by transforming failed trajectories into reusable guidance for later runs. We evaluate the framework on BI-RADS assessment and breast density estimation tasks. In our experiments, we find that tools alone do not reliably improve performance, whereas evolved skills can improve tool-use behavior and performance in some settings. Beyond these results, MammoClaw enables transparent inspection of evidence acquisition, tool interactions, and failure modes, facilitating the analysis and auditing of agent behavior. We view this work as an exploratory study of training-free, self-evolving agentic approaches for mammography and hope it provides a concrete starting point for future work on mammography-specific tools and self-evolution mechanisms. We release our code at https://krishnakanthnakka.github.io/mammoclaw.

0.63

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling

cs.CV ·2026-09-02 ·Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede +3 more
positioncode/data similarity 0.68
Abstract

There is growing interest in adopting CLIP-style vision--language model (VLM) pretraining for mammography. However, models that directly employ the standard CLIP architecture and training objective exhibit limited zero-shot performance in clinically important tasks such as cancer, finding-type, and BI-RADS predictions. We argue that this underwhelming performance is due to neglecting two characteristics of mammography data: (1) its high-res nature, and (2) homogeneity of radiology reports, largely driven by a predominance of negative/benign findings on examinations. We propose TopKSigLIP, a VLM designed to address these two limitations through a novel architecture and learning objectives. Instead of downscaling high-res mammography images to satisfy GPU memory constraints, TopKSigLIP introduces TopK-Patch module that learns to sample a sparse set of high-res patches likely to contain lesions, sidestepping the resolution--batch size tradeoff of VLM training. The sampled patch locations additionally serve as a built-in localization tool. To address report homogeneity, we replace the contrastive loss, which falsely repels semantically similar pairs, with a Sup-sigmoid loss. Sup-sigmoid loss extends the sigmoid loss from SigLIP with soft labels derived from structured data. TopKSigLIP outperforms existing open-source mammography and general medical VLMs on both internal and external benchmarks on density assessment, BI-RADS classification, finding subtyping, and cancer prediction under zero-shot evaluation. TopKSigLIP remains competitive under linear probing despite using a significantly smaller vision encoder and smaller training batches than baselines. The TopK-Patch module additionally achieves superior lesion localization over post-hoc Grad-CAM. Code and weights are made public:https://github.com/Youngseok0001/TopKSigLIP.

0.30

Evaluating Cross-Signal Coherence in Mammography Vision-Language Models

cs.CV cs.CLcs.LG ·2026-11-09 ·Rebeca Nam, Chase M. Fensore, Christian A. Fauria-Robinson, Judy Gichoya, Joyce C. Ho
similarity 0.68
Abstract

As vision-language models (VLMs) move toward interpreting medical images directly, their outputs increasingly include not just a label but a stated confidence and a written justification. Yet the field still predominantly evaluates VLMs using just accuracy. We evaluate the coherence between answer, confidence, and explanation across four VLMs on breast density and BI-RADS categorization, using two mammography datasets. We perform controlled perturbations of the question, multiple choice option orders, and the images and assess changes in the three outputs. Our results suggest confidence does not decrease even as the mammography image is changed. Shuffling the options also changes most VLMs' answers. Notably, there are cases where a model's own stated reasoning contradicts its final answer, a distinction accuracy alone cannot capture but one that governs whether an AI-generated answer can be trusted.

0.26

MammoMix: Leveraging Mixture of Experts for Robust Mammogram Breast Detection

cs.CV ·2026-08-11 ·Dinh Tan Nguyen, Hoang Quan Dang, Chen Zhang, Sai Ho Ling
published similarity 0.67
Abstract · Australasian Joint Conference on Artificial Intelligence 2025

Breast lesion detection in mammography remains a challenging task due to variations in image quality, lesion appearance, and population demographics across datasets. While current object detectors such as YOLO and DETR achieve strong results on individual datasets, their performance often degrades when trained on or applied across heterogeneous sources. To address this, we propose MammoMix, a novel framework based on Mixture-of-Experts (MoE) paradigm for robust and generalizable lesion detection. In MammoMix, each expert model is trained on a specific domain, allowing it to specialize in distinct characteristics of its source data. A gating mechanism adaptively weighs contributions from each expert based on input image, combining their outputs to enable domain-adaptive inference. To improve reliability, we further incorporate a calibration module, MoCAE, which adjusts confidence scores to reflect true predictive uncertainty. We evaluate MammoMix on 3 public mammography datasets: CSAW, DDSM, and DMID, covering diverse clinical settings. Results show that MammoMix outperforms baseline detectors in both average precision and reliability, particularly on datasets with greater variability. Our findings demonstrate that expert specialization and calibrated ensemble fusion significantly enhance model generalization and robustness. MammoMix offers a promising step toward dependable AI-assisted breast cancer screening across real-world clinical domains.

0.52

From Density to Biopsy Decisions and Malignancy Prediction: A Benchmark Study of Multimodal Large Language Models Against Radiologists in Digital and Contrast-Enhanced Mammography

cs.CV physics.med-ph ·2026-09-13 ·Ali Abbasian Ardakani, Afshin Mohammadi, Taha Yusuf Kuzan, Beyza Nur Kuzan, Alisa Mohebbi +9 more
benchmark similarity 0.67
Abstract · 37 pages, 6 figures, 5 tables

Purpose: To compare four multimodal large language models (MLLMs) with radiologists of varying expertise in breast density assessment, BI-RADS assessment, biopsy candidacy determination, and continuous malignancy probability estimation using digital mammography (DM) and contrast-enhanced mammography (CEM). Methods: This study included 179 women with paired DM/CEM examinations and reference standards. Four MLLMs (ChatGPT-5.2, Gemini-3.1 Pro, Sonnet-4.6, Muse Spark) interpreted images with and without masks; three radiologists interpreted non-masked images. Results: For binary density classification on DM, radiologist accuracies ranged from 55.81% to 78.60%, exceeding most MLLM values (62.33%-71.63%), while masks added limited benefit. Five-category BI-RADS accuracies were higher for radiologists on DM (56.74-67.44%) and CEM (62.33-82.79%) compared with MLLMs (DM 31.16-45.12%; CEM 40.00-55.81%). Binary biopsy-candidacy accuracies were likewise higher for radiologists (DM 85.12-89.77%; CEM 86.98-92.09%) than for MLLMs (DM 61.39-75.35%; CEM 69.30-82.79%), although CEM improved performance across all readers. Lesion masks substantially improved MLLM continuous malignancy-probability accuracies from 64.65%-71.63% to 72.56-78.60% on DM and from 67.91%-77.21% to 72.56%-81.86% on CEM, approaching radiologist ranges (DM 63.72-82.79%; CEM 81.86-88.84%). The corresponding AUCs for the top masked models overlapped those of the human readers. Overall, Muse Spark, followed by Sonnet-4.6, demonstrated the strongest performance among the MLLMs across domains. Conclusion: Radiologists generally outperformed MLLMs in categorical tasks, while selected masked models approached human performance for continuous malignancy probability estimation, suggesting a potential adjunctive role.

0.50

Impact of Input Resolution in Mammographic Mass Detection: A Controlled Multi-Architecture Study

cs.CV cs.AIcs.LG ·2026-11-03 ·Kaan Buyukdemirci, Emine Ulku Saritas
similarity 0.66
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Deep-learning-based mass detectors usually downsample mammograms, trading fine image detail for lower computational cost. However, published studies cannot reveal how much accuracy this trade-off sacrifices, since they also differ in architecture, preprocessing, and evaluation protocol. In this work, we isolated the effect of input resolution in a controlled study on the VinDr-Mammo dataset, training 18 detectors at six input resolutions ranging from 512 x 416 to 1600 x 1280 pixels, for 108 model-resolution combinations. Whole mammograms were resized without cropping or tiling. For each model, preprocessing, model initialization, augmentation, and evaluation procedures were kept fixed across resolutions. Detection accuracy was evaluated by mAP50 on the 219 mass-positive images of the official test split, and 57 combinations with test mAP50 of at least 0.60 were analyzed. From the lowest to the highest resolution, median mAP50 rose from 0.626 to 0.660 and the best mAP50 from 0.670 to 0.709. The best result, achieved by DINO with a ConvNeXt-S backbone, is the highest mAP50 reported to date on mass-positive VinDr-Mammo images. Gains were concentrated in small masses: for the smallest third of lesions, median mAP50 rose by 0.074 (from 0.367 to 0.441), compared with 0.007 and 0.032 for medium and large masses. Median training time increased from 0.45 to 1.40 h, and median inference time from 23.6 to 113.7 ms per image. Therefore, higher input resolution mainly benefits the small masses that are hardest to detect, at a computational cost that remains practical.

0.31

Do Saliency Maps Fail Dense Breasts? A Chance-Normalized, Confounder-Aware Audit of Explanation Fairness in Mammography

cs.CV cs.AI ·2026-11-04 ·Ahmed Jaheen
similarity 0.62
Abstract

Saliency maps, offered as evidence that mammography classifiers use the cancer, are untested in dense breasts, which can hide cancers. We tested whether they locate cancers worse there, and why. On 1,345 malignant CBIS-DDSM views, we scored three CNNs' Grad-CAM, Integrated Gradients and occlusion maps by whether their peak hits the lesion and a chance-normalized lesion-to-background saliency ratio (bits; +1 doubles it). Unadjusted gaps were large: Grad-CAM peaks hit 44% of dense vs. 58% of non-dense lesions. Case mix, chiefly more calcifications in dense breasts, explained about half or more of each gap. Occlusion kept a significant average of -0.56 bit gap. Controls also implicate the classifiers: unadjusted gaps exceeded an image-only conspicuity map's, and models relied less on dense-breast lesions. We recommend reporting density gaps before and after case-mix adjustment, per classifier, with conspicuity and lesion-reliance controls.

0.28

Modern Backbones Improve Multi-task DETR for Mammography Classification and Lesion Localization

cs.CV cs.AI ·2026-08-10 ·Dinh Tan Nguyen, Quang-Hien Kha, Le-Hoang Nguyen, Minh-Toan Dinh, Xuan-Huy Nguyen +6 more
similarity 0.62
Abstract · Medical Imaging with Deep Learning 2026 - Short Paper Track

Joint exam-level prediction and candidate-region localization may improve the usefulness of AI support in mammography. We study this setting using a multi-task DETR framework, where shared representations support both image-level malignancy prediction and lesion localization, and evaluate its performance on OPTIMAM and a biopsy-confirmed SGM1k cohort. Across both datasets, modern backbones consistently outperformed older ResNet-style features, with ConvNeXtV2 and DINOv3 giving the strongest overall results, whereas MambaVision was less competitive. On OPTIMAM, ConvNeXtV2 achieved the best overall performance, reaching 97.96% AUC, 99.89% sensitivity, 25.08% mAP@.5, and 74.38% recall@.25. On SGM1k, DINOv3 gave the strongest overall results, with 90.97% AUC, 86.28% sensitivity, 82.00% specificity, 27.04% mAP@.5, and 77.32% recall@.25. These findings suggest that backbone quality is a critical factor in effective multi-task mammography, with ConvNeXtV2 emerging as a particularly strong and well-matched CNN backbone for mammography in this framework.

0.04