CS Paper Radar

Impact of Input Resolution in Mammographic Mass Detection: A Controlled Multi-Architecture Study

Kaan Buyukdemirci, Emine Ulku Saritas

cs.CV cs.AIcs.LG ·submitted 2026-11-03 02:36 UTC · v1

Abstract

Deep-learning-based mass detectors usually downsample mammograms, trading fine image detail for lower computational cost. However, published studies cannot reveal how much accuracy this trade-off sacrifices, since they also differ in architecture, preprocessing, and evaluation protocol. In this work, we isolated the effect of input resolution in a controlled study on the VinDr-Mammo dataset, training 18 detectors at six input resolutions ranging from 512 x 416 to 1600 x 1280 pixels, for 108 model-resolution combinations. Whole mammograms were resized without cropping or tiling. For each model, preprocessing, model initialization, augmentation, and evaluation procedures were kept fixed across resolutions. Detection accuracy was evaluated by mAP50 on the 219 mass-positive images of the official test split, and 57 combinations with test mAP50 of at least 0.60 were analyzed. From the lowest to the highest resolution, median mAP50 rose from 0.626 to 0.660 and the best mAP50 from 0.670 to 0.709. The best result, achieved by DINO with a ConvNeXt-S backbone, is the highest mAP50 reported to date on mass-positive VinDr-Mammo images. Gains were concentrated in small masses: for the smallest third of lesions, median mAP50 rose by 0.074 (from 0.367 to 0.441), compared with 0.007 and 0.032 for medium and large masses. Median training time increased from 0.45 to 1.40 h, and median inference time from 23.6 to 113.7 ms per image. Therefore, higher input resolution mainly benefits the small masses that are hardest to detect, at a computational cost that remains practical.

Comment
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

Closest papers

Nearest neighbours by meaning across the whole index.

MammoSeek: A Mammography Agent with selective zooming for grounded reports

cs.CV ·2026-11-04 ·Haoyan Ding, Qian Wang, Lixia Wang, Debiao Li
similarity 0.66
Abstract · 5 pages, 2 figures

Radiologists read a screening mammogram by first forming a global impression of the four views and then selectively magnifying suspicious regions before assigning a BI-RADS assessment. MLLMs, in contrast, see the whole image at a fixed, reduced resolution, which makes sub-millimeter calcifications invisible, and they perform close to chance on mammography. Therefore, we present MammoSeek, a mammography agent that reproduces this reading process. After forming an impression of each breast, the agent performs selective zooming: it decides by itself which detector candidates deserve a closer look and inspects only those on full-resolution views. Guided by a BI-RADS assessment skill, it then assigns a category and generates a localized, lexicon-structured report for each breast; its assessment is combined with image-model scores in a decision layer to decide recall. On an internal (EMBED) and an external (VinDr-Mammo) dataset, \ours reaches exam-level AUCs of 0.824 and 0.818, far above other MLLMs, mammography agent and CNN classifiers. Selective zooming also outperforms both no zooming and forced zooming in localization, structured-report F1 and recall decisions at low cost.

0.29

Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models

eess.IV cs.CVq-bio.TO ·2026-10-01 ·Vasisht Ishwar, Hari Trivedi, Young Seok Jeon, Beatrice Brown-Mulry, Frank Li +3 more
similarity 0.64
Abstract · 15 pages, 6 figures, 2 tables. Submitted to the Journal of Imaging Informatics in Medicine

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.

0.12

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling

cs.CV ·2026-09-02 ·Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede +3 more
positioncode/data similarity 0.62
Abstract

There is growing interest in adopting CLIP-style vision--language model (VLM) pretraining for mammography. However, models that directly employ the standard CLIP architecture and training objective exhibit limited zero-shot performance in clinically important tasks such as cancer, finding-type, and BI-RADS predictions. We argue that this underwhelming performance is due to neglecting two characteristics of mammography data: (1) its high-res nature, and (2) homogeneity of radiology reports, largely driven by a predominance of negative/benign findings on examinations. We propose TopKSigLIP, a VLM designed to address these two limitations through a novel architecture and learning objectives. Instead of downscaling high-res mammography images to satisfy GPU memory constraints, TopKSigLIP introduces TopK-Patch module that learns to sample a sparse set of high-res patches likely to contain lesions, sidestepping the resolution--batch size tradeoff of VLM training. The sampled patch locations additionally serve as a built-in localization tool. To address report homogeneity, we replace the contrastive loss, which falsely repels semantically similar pairs, with a Sup-sigmoid loss. Sup-sigmoid loss extends the sigmoid loss from SigLIP with soft labels derived from structured data. TopKSigLIP outperforms existing open-source mammography and general medical VLMs on both internal and external benchmarks on density assessment, BI-RADS classification, finding subtyping, and cancer prediction under zero-shot evaluation. TopKSigLIP remains competitive under linear probing despite using a significantly smaller vision encoder and smaller training batches than baselines. The TopK-Patch module additionally achieves superior lesion localization over post-hoc Grad-CAM. Code and weights are made public:https://github.com/Youngseok0001/TopKSigLIP.

0.30

DualMiT-Net: Local-Global Transformer-Convolutional Fusion for Breast Mass Segmentation in Mammographic Regions of Interest

cs.CV cs.AIcs.LG ·2026-08-15 ·Alibek Kamiluly, Milana Muratova, Yash Patel, Fan Li
similarity 0.62
Abstract

Breast mass segmentation is an important step in computer-aided mammography, but it remains difficult because masses can have low contrast, irregular shapes, and boundaries that blend with surrounding breast tissue. To address this problem, we present DualMiT-Net, a dual-branch network that uses both a focused view of the mass and a wider view of the surrounding tissue. The local branch uses a Mix Transformer (MiT-B5) encoder to learn mass shape, texture, and boundary information, while the global branch uses an EfficientNet-B5 encoder to learn surrounding breast context. Features from the two branches are shared at the deeper encoder levels and are then progressively fused in a single decoder. A spatial gate controls how much global information is added during decoding. We also evaluated four input representations and selected a percentile-windowed mammogram combined with a Gabor texture response. The model was trained and evaluated on the mass subset of the Curated Breast Imaging Subset of the Digital Database for Screening Mammography (CBIS-DDSM) using a patient-level split. Across three training runs, DualMiT-Net with exponential moving average weights achieved a mean Dice coefficient of 0.9375 and a mean Intersection over Union of 0.8834. It also achieved better Dice and IoU scores than six standard encoder-decoder baselines trained using the same data and training settings. These results show that combining local mass information with wider breast context can provide accurate and consistent breast mass segmentation.

0.04

MammoMix: Leveraging Mixture of Experts for Robust Mammogram Breast Detection

cs.CV ·2026-08-11 ·Dinh Tan Nguyen, Hoang Quan Dang, Chen Zhang, Sai Ho Ling
published similarity 0.62
Abstract · Australasian Joint Conference on Artificial Intelligence 2025

Breast lesion detection in mammography remains a challenging task due to variations in image quality, lesion appearance, and population demographics across datasets. While current object detectors such as YOLO and DETR achieve strong results on individual datasets, their performance often degrades when trained on or applied across heterogeneous sources. To address this, we propose MammoMix, a novel framework based on Mixture-of-Experts (MoE) paradigm for robust and generalizable lesion detection. In MammoMix, each expert model is trained on a specific domain, allowing it to specialize in distinct characteristics of its source data. A gating mechanism adaptively weighs contributions from each expert based on input image, combining their outputs to enable domain-adaptive inference. To improve reliability, we further incorporate a calibration module, MoCAE, which adjusts confidence scores to reflect true predictive uncertainty. We evaluate MammoMix on 3 public mammography datasets: CSAW, DDSM, and DMID, covering diverse clinical settings. Results show that MammoMix outperforms baseline detectors in both average precision and reliability, particularly on datasets with greater variability. Our findings demonstrate that expert specialization and calibrated ensemble fusion significantly enhance model generalization and robustness. MammoMix offers a promising step toward dependable AI-assisted breast cancer screening across real-world clinical domains.

0.52

Modern Backbones Improve Multi-task DETR for Mammography Classification and Lesion Localization

cs.CV cs.AI ·2026-08-10 ·Dinh Tan Nguyen, Quang-Hien Kha, Le-Hoang Nguyen, Minh-Toan Dinh, Xuan-Huy Nguyen +6 more
similarity 0.60
Abstract · Medical Imaging with Deep Learning 2026 - Short Paper Track

Joint exam-level prediction and candidate-region localization may improve the usefulness of AI support in mammography. We study this setting using a multi-task DETR framework, where shared representations support both image-level malignancy prediction and lesion localization, and evaluate its performance on OPTIMAM and a biopsy-confirmed SGM1k cohort. Across both datasets, modern backbones consistently outperformed older ResNet-style features, with ConvNeXtV2 and DINOv3 giving the strongest overall results, whereas MambaVision was less competitive. On OPTIMAM, ConvNeXtV2 achieved the best overall performance, reaching 97.96% AUC, 99.89% sensitivity, 25.08% mAP@.5, and 74.38% recall@.25. On SGM1k, DINOv3 gave the strongest overall results, with 90.97% AUC, 86.28% sensitivity, 82.00% specificity, 27.04% mAP@.5, and 77.32% recall@.25. These findings suggest that backbone quality is a critical factor in effective multi-task mammography, with ConvNeXtV2 emerging as a particularly strong and well-matched CNN backbone for mammography in this framework.

0.04

Clinical Feasibility of Low-Magnification Fluorescence Imaging for Breast Cancer Margin Detection Using Texture Analysis and Deep Learning

cs.CV cs.AIcs.LG ·2026-08-11 ·Pouya Afshin, Tianling Niu, Tongtong Lu, David Helminiak, Julie Jorns +4 more
published similarity 0.58
Abstract · This research has been accepted and published in Journal "Biomedical Optics Express" in July 2026 with Manuscript ID is 596807

High-resolution images of unprocessed surgical breast tissue can be obtained using microscopy with ultraviolet surface excitation (MUSE). This technique is considered a promising method for checking surgical margins during breast cancer surgery. In this study, MUSE images at 4x and 10x magnifications were compared using patch-level classification methods. Texture analysis (TA) based on local binary patterns (LBP) and deep learning (DL) with a base Vision Transformer (ViT) model were used. Both methods achieved similar performance at both magnifications. Using DL method, both 4x and 10x magnifications achieved 96.30% sensitivity, 100% specificity and 98.18% accuracy. Using TA method, 4x achieved better specificity (100% vs 93.33%) and 10x yielded higher sensitivity (100% vs 93.33%), but both had the same accuracy (96.67%). No clear improvement in performance was observed with 10x magnification. These results show that 4x imaging achieves the same diagnostic accuracy as 10x imaging. At the same time, 4x offers a larger field of view and faster image capture. Therefore, lower magnification can be effectively used in MUSE systems for accurate and efficient intraoperative margin assessment.

0.28

One Model to Magnify Them All: Efficient Scale-Invariant Histopathology via Conditional Normalization and Continuous Magnification Training

cs.CV ·2026-08-10 ·Agnieszka Florkowska, Henning Müller, Marek Wodzinski
code/data similarity 0.56
Abstract

Whole slide images (WSIs) in digital histopathology are acquired at discrete magnification levels encoding complementary diagnostic information from global tissue architecture to fine-grained cellular morphology. Yet, deep learning models remain sensitive to scale variation. Existing magnification-invariant methods rely on multi-scale architectures at predefined discrete resolutions, while in clinical deployment the acquisition magnification varies continuously, rarely aligns with a model's fixed training resolution, and intermediate scales are common, so robust coverage otherwise demands a costly ensemble of magnification-specific models. We propose Conditional Layer Normalization (CLN), a lightweight mechanism that generates affine normalization parameters from input pixel size via a small MLP, integrated into standard CNN architectures for both WSI classification and segmentation. Trained on patches sampled continuously across a range of pixel sizes, the model decouples inference from scanner-dependent magnification and generalizes to arbitrary, previously unseen scales at test time. On the PANDA prostate cancer dataset, our approach on average matches or exceeds independently trained single-magnification models and ranks among the top three performers at every evaluated magnification, including those unseen during training. This collapses a five-model ensemble into a single network and reduces training, and inference cost roughly 4-5 times, while leaving the multiply-accumulate count unchanged. The code is available at: https://github.com/aflorkowska/OneModelToMagnifyThemAll.

0.24