CS Paper Radar

Clinical Feasibility of Low-Magnification Fluorescence Imaging for Breast Cancer Margin Detection Using Texture Analysis and Deep Learning

Pouya Afshin, Tianling Niu, Tongtong Lu, David Helminiak, Julie Jorns, Mollie Patton, Tina Yen, Donghye Ye, Bing Yu

cs.CV cs.AIcs.LG ·submitted 2026-08-11 18:08 UTC · v1
published

Abstract

High-resolution images of unprocessed surgical breast tissue can be obtained using microscopy with ultraviolet surface excitation (MUSE). This technique is considered a promising method for checking surgical margins during breast cancer surgery. In this study, MUSE images at 4x and 10x magnifications were compared using patch-level classification methods. Texture analysis (TA) based on local binary patterns (LBP) and deep learning (DL) with a base Vision Transformer (ViT) model were used. Both methods achieved similar performance at both magnifications. Using DL method, both 4x and 10x magnifications achieved 96.30% sensitivity, 100% specificity and 98.18% accuracy. Using TA method, 4x achieved better specificity (100% vs 93.33%) and 10x yielded higher sensitivity (100% vs 93.33%), but both had the same accuracy (96.67%). No clear improvement in performance was observed with 10x magnification. These results show that 4x imaging achieves the same diagnostic accuracy as 10x imaging. At the same time, 4x offers a larger field of view and faster image capture. Therefore, lower magnification can be effectively used in MUSE systems for accurate and efficient intraoperative margin assessment.

Comment
This research has been accepted and published in Journal "Biomedical Optics Express" in July 2026 with Manuscript ID is 596807
Journal ref
Biomedical Optics Express 2026
DOI
10.1364/BOE.596807

Closest papers

Nearest neighbours by meaning across the whole index.

DualMiT-Net: Local-Global Transformer-Convolutional Fusion for Breast Mass Segmentation in Mammographic Regions of Interest

cs.CV cs.AIcs.LG ·2026-08-15 ·Alibek Kamiluly, Milana Muratova, Yash Patel, Fan Li
similarity 0.65
Abstract

Breast mass segmentation is an important step in computer-aided mammography, but it remains difficult because masses can have low contrast, irregular shapes, and boundaries that blend with surrounding breast tissue. To address this problem, we present DualMiT-Net, a dual-branch network that uses both a focused view of the mass and a wider view of the surrounding tissue. The local branch uses a Mix Transformer (MiT-B5) encoder to learn mass shape, texture, and boundary information, while the global branch uses an EfficientNet-B5 encoder to learn surrounding breast context. Features from the two branches are shared at the deeper encoder levels and are then progressively fused in a single decoder. A spatial gate controls how much global information is added during decoding. We also evaluated four input representations and selected a percentile-windowed mammogram combined with a Gabor texture response. The model was trained and evaluated on the mass subset of the Curated Breast Imaging Subset of the Digital Database for Screening Mammography (CBIS-DDSM) using a patient-level split. Across three training runs, DualMiT-Net with exponential moving average weights achieved a mean Dice coefficient of 0.9375 and a mean Intersection over Union of 0.8834. It also achieved better Dice and IoU scores than six standard encoder-decoder baselines trained using the same data and training settings. These results show that combining local mass information with wider breast context can provide accurate and consistent breast mass segmentation.

0.04

Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models

eess.IV cs.CVq-bio.TO ·2026-10-01 ·Vasisht Ishwar, Hari Trivedi, Young Seok Jeon, Beatrice Brown-Mulry, Frank Li +3 more
similarity 0.64
Abstract · 15 pages, 6 figures, 2 tables. Submitted to the Journal of Imaging Informatics in Medicine

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.

0.12

MagViT: Interpretable Multi-Magnification Transformers with Patient-Level Model Selection for Breast Histopathology

eess.IV cs.CVcs.LG ·2026-08-16 ·Nabil Ashab, Soumit Kumar Kundu, Saif Mahmud Parvez, Shahadat Hossain Sohag, Bidhan Biswas +1 more
published similarity 0.63
Abstract · 13 pages, 5 figures, Accepted for publication in the International Conference on Electrical, Computer and Communication Technologies (ECCT 2…

Breast cancer is one of the most common types of cancer among women around the world. Rapid detection and early treatment can hinder its progress to more complex stages and can impede its spread to other parts of the body. Histopathological image classification is the most common task in cancer detection due to its robustness in analyzing cellular data. Breast histopathology classification requires handling both multi-scale tissue morphology and clinically relevant generalization beyond the source domain. This paper presents MagViT, an interpretable multi-magnification transformer framework with scale-gated fusion and patient-level model selection. The model uses four BreakHis magnifications (40X, 100X, 200X, 400X) and extracts per-scale representations with a ViT backbone, and combines them via a learnable gate that masks missing scales. Patient-level five-fold cross-validation with a fixed seed has been run and compared with three architectural branches. The most accurate branch is then selected as the final model due to the strongest patient-level accuracy while retaining the simplest fusion pathway. On BreakHis, our architecture achieves a mean image accuracy of 0.9191, a mean patient accuracy of 0.9643, and a mean macro-F1 of 0.9042. External transfer experiments provide preliminary evidence of cross-dataset generalization under controlled adaptation settings on BUSI (image accuracy 0.8306, macro-F1 0.7480, patient accuracy 0.8291) and IDC (image accuracy 0.8577, macro-F1 0.8191, patient accuracy 0.8372). Grad-CAM visualization indicates that the model focuses on diagnostically significant and meaningful regions across magnifications. Relative to prior ViT-centered BreakHis work, this study emphasizes patient-level selection and cross-dataset robustness under a reproducible protocol.

0.25

Hybrid Cross-Modal Attention Network for Early Breast Cancer Detection in Low-Resource Clinical Settings

cs.CV cs.LG ·2026-10-05 ·Simon Hadush Nrea, Filimon Gidey Gebremichael, Gebrekirstos Hagos Gebrekirstos, Yaecob Girmay Gezahegn
publishedhot direction similarity 0.59
Abstract · 5 double pages numbers, conference paper presented at AI4SD 2026 (https://www.mu.edu.et/index.php/component/content/article/artificial-intel…

Breast cancer is the leading cause of cancer-related mortality among women in Sub-Saharan Africa, where delayed diagnosis results from limited radiology expertise and fragmented clinical data systems. Although deep learning models have demonstrated strong performance in mammographic analysis, most rely solely on imaging data and are trained on Western populations, limiting their applicability in African healthcare settings. This paper presents a Hybrid Cross-Modal Attention Network (HCMAN) that integrates mammogram images with structured clinical data using transformer-based cross-modal attention mechanisms. The model was developed and validated using a locally collected dataset of 2,560 mammogram images from 1,024 patients across four Ethiopian referral hospitals, with biopsy-confirmed ground truth labels. The proposed framework achieves 97.8% accuracy, 97.2% sensitivity, 98.3% specificity, and an AUC of 0.987, significantly outperforming image-only baselines. The system demonstrates robustness to low-quality images typical of resource-limited settings, with only 3.2% performance degradation compared to 8.7% for image-only models. Cross-modal attention analysis reveals clinically appropriate behavior: higher reliance on clinical features for ambiguous cases such as dense breasts and young patients. The model's lightweight architecture enables deployment on standard hospital workstations (<2 seconds inference on CPU). This work advances sustainable, context-aware AI solutions for equitable breast cancer diagnostics in Africa.

0.40

Neoadjuvant chemotherapy response prediction using pretreatment diffusion and contrast-enhanced magnetic resonance imaging with clinical variables

cs.AI cs.CV ·2026-08-18 ·Pablo García Marcos, Paula Puerta González, Guillermo Lorenzo, Héctor Gómez, Covadonga del Camino +4 more
similarity 0.59
Abstract

Prediction of pathological complete response before neoadjuvant chemotherapy may facilitate more tailored therapeutic planning for breast cancer patients. This work proposes a deep-learning model for pretreatment data only, combining apparent diffusion coefficient maps, dynamic contrast-enhanced magnetic resonance imaging, and clinical variables. The study uses the public ACRIN 6698/I-SPY2 multicenter dataset. The architecture employs EfficientNet-B0 pretrained encoders for image feature extraction and late fusion with clinical information. Multiple clinical variables were evaluated, including age, race, histological type, HR/HER2 subtype, SBR grade, and maximum diameter. Only HR/HER2 subtype improved the average area under the receiver operating characteristic curve (AUC) and was retained in the final model. Using stratified five-fold cross-validation, standalone apparent diffusion coefficient maps achieved a mean AUC of 0.79, whereas dynamic contrast-enhanced magnetic resonance imaging achieved 0.74. Adding HR/HER2 subtype improved performance to 0.83 and 0.81, respectively. The final configuration, using both imaging modalities and HR/HER2 subtype, achieved an AUC of 0.86. These results support pretreatment multimodal learning for response prediction, although external validation is required before clinical use.

0.27

Less Contouring, More Accuracy: Lesion-Guided ROI Deep Learning for Ovarian Ultrasound Classification

cs.CV ·2026-08-26 ·Mehran Ahmad, Ali Abbasian Ardakani, Afshin Mohammadi, Alisa Mohebbi, Gernot Kronreif +1 more
similarity 0.58
Abstract · Submitted as a research article. The manuscript contains figures, tables, and supplementary material

Ovarian lesion classification using transvaginal ultrasound remains challenging due to overlapping imaging characteristics and the dependence on expert interpretation. This study investigates whether lesion-guided region-of-interest (ROI) deep learning can achieve competitive diagnostic performance while reducing the annotation burden associated with pixel-level lesion segmentation. Two publicly available ovarian ultrasound datasets were evaluated: the Multi-Modality Ovarian Tumor Ultrasound (MMOTU) dataset for eight-class classification and the Ovarian Ultrasound Dataset (OUD) for binary classification. Four strategies were compared under a unified framework: global image-based deep learning, lesion-guided ROI-based deep learning, lesion contour-based deep learning, and contour-based radiomics with machine learning classifiers. Four deep learning architectures, MaxViT-Tiny, Swin Transformer, EfficientNet-B7, and ResNet18, were evaluated. Radiomics models were developed using support vector machine, k-nearest neighbors, and artificial neural network classifiers, with ANOVA-based feature selection applied for the lower-sample OUD dataset. The lesion-guided ROI strategy achieved the strongest overall performance, with MaxViT-Tiny obtaining 93.10% accuracy and an AUC of 0.99 on MMOTU and 97.56% accuracy and an AUC of 0.99 on OUD. The contour-based approach achieved comparable accuracy but required substantially higher annotation effort. These findings demonstrate that lesion-guided ROI deep learning provides an effective balance between diagnostic performance and annotation efficiency, offering a practical approach for scalable AI-assisted ovarian ultrasound analysis

0.09

Impact of Input Resolution in Mammographic Mass Detection: A Controlled Multi-Architecture Study

cs.CV cs.AIcs.LG ·2026-11-03 ·Kaan Buyukdemirci, Emine Ulku Saritas
similarity 0.58
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Deep-learning-based mass detectors usually downsample mammograms, trading fine image detail for lower computational cost. However, published studies cannot reveal how much accuracy this trade-off sacrifices, since they also differ in architecture, preprocessing, and evaluation protocol. In this work, we isolated the effect of input resolution in a controlled study on the VinDr-Mammo dataset, training 18 detectors at six input resolutions ranging from 512 x 416 to 1600 x 1280 pixels, for 108 model-resolution combinations. Whole mammograms were resized without cropping or tiling. For each model, preprocessing, model initialization, augmentation, and evaluation procedures were kept fixed across resolutions. Detection accuracy was evaluated by mAP50 on the 219 mass-positive images of the official test split, and 57 combinations with test mAP50 of at least 0.60 were analyzed. From the lowest to the highest resolution, median mAP50 rose from 0.626 to 0.660 and the best mAP50 from 0.670 to 0.709. The best result, achieved by DINO with a ConvNeXt-S backbone, is the highest mAP50 reported to date on mass-positive VinDr-Mammo images. Gains were concentrated in small masses: for the smallest third of lesions, median mAP50 rose by 0.074 (from 0.367 to 0.441), compared with 0.007 and 0.032 for medium and large masses. Median training time increased from 0.45 to 1.40 h, and median inference time from 23.6 to 113.7 ms per image. Therefore, higher input resolution mainly benefits the small masses that are hardest to detect, at a computational cost that remains practical.

0.31

A Lightweight CNN Integrated Compact Convolutional Transformer for Multi-Scale Feature Learning and reducing computational complexity for breast cancer mammography image detection and classification

cs.LG cs.AIcs.CV ·2026-09-16 ·Md Taimur Ahad, Ainuddin Ahmed
similarity 0.57
Abstract

Over the years, Convolutional Neural Networks (CNNs) have demonstrated strong capability in cancer detection and classification using medical images. However, CNN-based models often struggle to capture long-range contextual dependencies. In such scenarios, integrating Compact Convolutional Transformer (CCT) architectures after the CCT layer allows CNN-extracted features to reshape into compact patch tokens using a CCT tokenizer, followed by the addition of positional embeddings to preserve spatial structure. Using 5-fold cross-validation, the model was tested on 3 sets of breast cancer mammography. With only 250,435 parameters, the model achieved 99%-100% accuracy across 3 datasets, indicating robust generalization. Explainable AI (XAI) was integrated into the model to explain the breast cancer classification process to enhance clinical trust. The results indicate that the proposed framework is suitable for computer-aided diagnosis systems, particularly in resource-constrained clinical environments. The novelty of the proposed CNN-integrated CCT overcomes the limitation of CNN's gradient degradation in the last layers by integrating convolutional tokenization with transformer-based learning. Lighter than ViT, which is effective in capturing long-range dependencies, the model has also proven efficient in breast cancer classification by capturing long-range dependencies among breast tissue regions.

0.20