Breast cancer is the leading cause of cancer-related mortality among women in Sub-Saharan Africa, where delayed diagnosis results from limited radiology expertise and fragmented clinical data systems. Although deep learning models have demonstrated strong performance in mammographic analysis, most rely solely on imaging data and are trained on Western populations, limiting their applicability in African healthcare settings. This paper presents a Hybrid Cross-Modal Attention Network (HCMAN) that integrates mammogram images with structured clinical data using transformer-based cross-modal attention mechanisms. The model was developed and validated using a locally collected dataset of 2,560 mammogram images from 1,024 patients across four Ethiopian referral hospitals, with biopsy-confirmed ground truth labels. The proposed framework achieves 97.8% accuracy, 97.2% sensitivity, 98.3% specificity, and an AUC of 0.987, significantly outperforming image-only baselines. The system demonstrates robustness to low-quality images typical of resource-limited settings, with only 3.2% performance degradation compared to 8.7% for image-only models. Cross-modal attention analysis reveals clinically appropriate behavior: higher reliance on clinical features for ambiguous cases such as dense breasts and young patients. The model's lightweight architecture enables deployment on standard hospital workstations (<2 seconds inference on CPU). This work advances sustainable, context-aware AI solutions for equitable breast cancer diagnostics in Africa.

Comment
5 double pages numbers, conference paper presented at AI4SD 2026 (https://www.mu.edu.et/index.php/component/content/article/artificial-intelligence-for-sustainable-development-conference-participants?catid=69&Itemid=101)

Closest papers

Nearest neighbours by meaning across the whole index.

M3D-Net: Hierarchical Coordination of Spatial Context, Feature Reuse, and Differential Attention for Mammography Classification

cs.CV cs.LG ·2026-09-23 ·Zheng Yu, Xinhang Li, Jiabao Gao, Boyang Wang, Xiang Li
similarity 0.72
Abstract · Submitted to IEEE ICASSP 2027; 5 pages, 4 figures

Breast image classification requires local detail and global tissue context, yet these cues can weaken as representations deepen. We present M3D-Net, a mammography encoder that hierarchically coordinates multi-scale coordinate attention, bounded dynamic feature reuse, and differential attention through resolution-aware operator placement. Within-stage retrieval preserves access to earlier features, coordinate-aware aggregation integrates local and global context, and differential attention operates at coarse resolutions. We evaluate image-only classification on AISSLab mammography and an adapted image--clinical model on BrEaST ultrasound. Against EdgeNeXt, RepViT, and TransXNet, the proposed implementations achieve the highest recorded validation accuracy and late-training accuracy, with the lowest endpoint cross-entropy loss. Validation accuracies reach 97.78\% and 80.39\%, respectively. These results support further evaluation of hierarchical coordination across breast imaging settings; repeated-seed, component-controlled, and independent evaluations remain necessary.

0.23

A Lightweight CNN Integrated Compact Convolutional Transformer for Multi-Scale Feature Learning and reducing computational complexity for breast cancer mammography image detection and classification

cs.LG cs.AIcs.CV ·2026-09-16 ·Md Taimur Ahad, Ainuddin Ahmed
similarity 0.68
Abstract

Over the years, Convolutional Neural Networks (CNNs) have demonstrated strong capability in cancer detection and classification using medical images. However, CNN-based models often struggle to capture long-range contextual dependencies. In such scenarios, integrating Compact Convolutional Transformer (CCT) architectures after the CCT layer allows CNN-extracted features to reshape into compact patch tokens using a CCT tokenizer, followed by the addition of positional embeddings to preserve spatial structure. Using 5-fold cross-validation, the model was tested on 3 sets of breast cancer mammography. With only 250,435 parameters, the model achieved 99%-100% accuracy across 3 datasets, indicating robust generalization. Explainable AI (XAI) was integrated into the model to explain the breast cancer classification process to enhance clinical trust. The results indicate that the proposed framework is suitable for computer-aided diagnosis systems, particularly in resource-constrained clinical environments. The novelty of the proposed CNN-integrated CCT overcomes the limitation of CNN's gradient degradation in the last layers by integrating convolutional tokenization with transformer-based learning. Lighter than ViT, which is effective in capturing long-range dependencies, the model has also proven efficient in breast cancer classification by capturing long-range dependencies among breast tissue regions.

0.20

BreastMammo and DenseMammo: Benchmarks for Mammography Domain Generalization

eess.IV cs.LG ·2026-08-10 ·Hongyi Pan, Gorkem Durak, Halil Ertugrul Aktas, Andrea Mia Bejar, Mustafa Ege Seker +16 more
published similarity 0.67
Abstract · This paper was accepted to the MICCAI 2026 workshop Deep-Brea3th

Breast density classification is a critical component of breast cancer risk assessment, yet AI models often struggle to generalize across clinical sites due to vendor-specific acquisition styles. In this work, we introduce two new datasets, BreastMammo and DenseMammo, to facilitate robust multi-view mammography research. We propose a domain generalization framework that utilizes a foreground-only histogram matching protocol to resolve the domain shift issue arising from disparate clinical sources. Internal evaluation using a 5-fold cross-validation protocol demonstrates the efficacy of our approach, with the Swin Transformer backbone achieving a peak AUC of 98.32% for density classification. External evaluation on the TNMammo and LUMINA datasets demonstrates that the proposed approach consistently reduces domain shift, significantly outperforming prominent domain generalization paradigms, including MixStyle and Discrete-Fourier-Transform-based frameworks.

0.18

Interpretable Deep Learning Models for Breast Cancer Diagnosis Using Medical Imaging

cs.CV cs.AI ·2026-10-27 ·Sami Alnawali, Muhammad Atif Saeed, Abdul Hadi, Azka Atiq, Akhtar Jamil +1 more
benchmark similarity 0.67
Abstract · 37 page, 45 Figures

Deep learning shows promise for breast cancer diagnosis, but limited interpretability hinders clinical adoption. We benchmark ten ImageNet-pretrained models (ResNet50, VGG19, InceptionV3, DenseNet121, Xception, MobileNetV2, EfficientNet, ConvNeXt, ViT, and Swin Transformer) for benign-versus-malignant classification on the BreakHis histopathology dataset using a patient-level split, and explain their predictions with Grad-CAM, LIME, Integrated Gradients, and LRP. DenseNet121 performed best, with 99.4% test accuracy and an AUC-ROC of 0.999, and significantly outperformed all other models (p < 0.001). Transformer-based models trailed the CNNs. The explanations consistently highlighted nuclei-rich and glandular regions of diagnostic relevance. Combining transfer learning with explainable AI can thus yield accurate, interpretable tools for breast cancer diagnosis.

0.19

DualMiT-Net: Local-Global Transformer-Convolutional Fusion for Breast Mass Segmentation in Mammographic Regions of Interest

cs.CV cs.AIcs.LG ·2026-08-15 ·Alibek Kamiluly, Milana Muratova, Yash Patel, Fan Li
similarity 0.66
Abstract

Breast mass segmentation is an important step in computer-aided mammography, but it remains difficult because masses can have low contrast, irregular shapes, and boundaries that blend with surrounding breast tissue. To address this problem, we present DualMiT-Net, a dual-branch network that uses both a focused view of the mass and a wider view of the surrounding tissue. The local branch uses a Mix Transformer (MiT-B5) encoder to learn mass shape, texture, and boundary information, while the global branch uses an EfficientNet-B5 encoder to learn surrounding breast context. Features from the two branches are shared at the deeper encoder levels and are then progressively fused in a single decoder. A spatial gate controls how much global information is added during decoding. We also evaluated four input representations and selected a percentile-windowed mammogram combined with a Gabor texture response. The model was trained and evaluated on the mass subset of the Curated Breast Imaging Subset of the Digital Database for Screening Mammography (CBIS-DDSM) using a patient-level split. Across three training runs, DualMiT-Net with exponential moving average weights achieved a mean Dice coefficient of 0.9375 and a mean Intersection over Union of 0.8834. It also achieved better Dice and IoU scores than six standard encoder-decoder baselines trained using the same data and training settings. These results show that combining local mass information with wider breast context can provide accurate and consistent breast mass segmentation.

0.04

Cross-modal triage network: a multimodal deep learning framework for severity-based triage and visual explainability in chest radiographs

eess.IV cs.AIcs.CV ·2026-09-03 ·Zinah Ghulam, Richa Mittal, Eranga Ukwatta
benchmark similarity 0.66
Abstract

Purpose: Increased number of chest radiograph (CXR) scans create a triage bottleneck, queueing urgent examinations behind routine ones. Existing AI tools are predominantly unimodal binary classifiers lacking severity awareness, and multimodal systems are rarely benchmarked against expert radiologists. To this end, we developed a multimodal deep learning framework for joint severity triage, pathology detection, and native visual explanation. Approach: We propose the cross-modal triage network (CMTN), fusing a Swin Transformer V2 visual encoder with a PubMedBERT text encoder via gated cross-attention. The CMTN was trained on 34,639 image-text pairs (12,489 patients) from MIMIC-CXR-JPG, optimizing an ordinal focal loss for four-tier severity triage and binary cross-entropy for 14 pathologies. Beyond quantitative benchmarking, attention heatmaps were evaluated against a blinded expert radiologist in a two-phase clinical audit comparing model triage output to expert severity assessment (100 cases) and grading spatial-semantic concordance (116 heatmaps). Results: The CMTN achieved strong ordinal agreement with reference labels (quadratic weighted kappa [QWK] = 0.9341, 95\% CI: 0.9219 to 0.9449) and macro-AUROC of 0.9970 across 14 pathologies, with 34~ms latency, outperforming the state-of-the-art BioViL multimodal baseline (QWK = 0.7679). However, the blinded Phase I clinical audit revealed substantially lower agreement with genuine radiologist judgment (QWK = 0.1399). Phase II found 54.3\% of heatmaps achieved clinically acceptable spatial localization. Conclusions: The CMTN demonstrated an efficient multimodal architecture for CXR triage. The divergence between algorithmic and radiologist agreement demonstrates that benchmark performance against NLP-derived labels is insufficient, highlighting the need for radiologist-labeled ground truth before clinical deployment.

0.21

A Lightweight Attention-Based CNN with Saliency-Map Interpretability for Skin Cancer Detection

cs.CV cs.AI ·2026-10-27 ·Sanjana Islam Kasfia, Md. Ismiel Hossen Abir, AKM Bahalul Haque, Abir Mahmud Shahariar
similarity 0.66
Abstract

Skin cancer is among the most prevalent and life threatening forms of cancer worldwide. Early and accurate diagnosis significantly improves patient survival rates. However, manual dermoscopic assessment remains challenging due to visual similarity. This study proposes an Explainable AI-driven framework for automated binary classification of skin lesions using a lightweight attention-based convolutional neural network (CNN-Attention). The model integrates channel attention to focus on informative regions of dermoscopic images while maintaining low computational complexity. A publicly available dataset comprising 2,637 training and 660 test images was used, with balanced class weights. The proposed model achieved 87 percent accuracy with 1.95 million parameters and 7.45 MB of storage, matching the best baseline (MobileNet) while using approximately half as many parameters and half as much storage. ROC AUC and PR AUC scores reached 0.9475 and 0.9430, respectively. Additionally, saliency maps were incorporated as an explainability technique to visualize regions that influence model decisions. Comparative analysis with VGG16,VGG19,ResNet101,and MobileNet demonstrates the proposed models effectiveness in balancing classification results, computational efficiency, and interpretability.

0.09

CheXFuse: Guided Differential Joint Attention Fusion for Robust Multimodal Chest X-Ray Classification in Data-Scarce Medical Settings

cs.CV cs.LG ·2026-10-19 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
publishedhighly cited similarity 0.66
Abstract · IEEE ICDM DMBIH 2026

A central challenge in multimodal learning is how to fuse modalities that differ substantially in predictive strength. When one modality provides a much stronger representation than another, indiscriminate cross-modal interaction can introduce weak, redundant, or unstable signals, limiting or even degrading performance relative to the strongest unimodal representation. To address this problem, we propose CheXFuse, a multimodal fusion framework based on Guided Differential Joint Attention (GuDJA). CheXFuse combines image and text token representations within a joint multimodal sequence, where learned token guidance emphasizes informative representations and differential attention reduces less useful attention responses. We evaluate CheXFuse on the Indiana University (IU) Chest X-ray dataset, using binary (normal vs. abnormal) classification as the downstream task. Experiments are conducted under both original-report and masked-report settings, with the latter serving as a controlled stress test under reduced textual informativeness. CheXFuse with GuDJA achieves the strongest mean overall performance across the evaluated baselines and ablations, reaching 95.73% accuracy, 95.79% F1-score, 96.54% recall, and 95.28% sensitivity at 95% specificity (Sens@95Spec) with original reports, and 95.58%, 95.60%, 95.60%, and 94.34%, respectively, under masked reports. These results suggest that GuDJA provides a promising fusion strategy under asymmetric or partially reduced modality informativeness.

0.49