CS Paper Radar

Less Contouring, More Accuracy: Lesion-Guided ROI Deep Learning for Ovarian Ultrasound Classification

Mehran Ahmad, Ali Abbasian Ardakani, Afshin Mohammadi, Alisa Mohebbi, Gernot Kronreif, Sepideh Hatamikia

cs.CV ·submitted 2026-08-26 16:22 UTC · v1

Abstract

Ovarian lesion classification using transvaginal ultrasound remains challenging due to overlapping imaging characteristics and the dependence on expert interpretation. This study investigates whether lesion-guided region-of-interest (ROI) deep learning can achieve competitive diagnostic performance while reducing the annotation burden associated with pixel-level lesion segmentation. Two publicly available ovarian ultrasound datasets were evaluated: the Multi-Modality Ovarian Tumor Ultrasound (MMOTU) dataset for eight-class classification and the Ovarian Ultrasound Dataset (OUD) for binary classification. Four strategies were compared under a unified framework: global image-based deep learning, lesion-guided ROI-based deep learning, lesion contour-based deep learning, and contour-based radiomics with machine learning classifiers. Four deep learning architectures, MaxViT-Tiny, Swin Transformer, EfficientNet-B7, and ResNet18, were evaluated. Radiomics models were developed using support vector machine, k-nearest neighbors, and artificial neural network classifiers, with ANOVA-based feature selection applied for the lower-sample OUD dataset. The lesion-guided ROI strategy achieved the strongest overall performance, with MaxViT-Tiny obtaining 93.10% accuracy and an AUC of 0.99 on MMOTU and 97.56% accuracy and an AUC of 0.99 on OUD. The contour-based approach achieved comparable accuracy but required substantially higher annotation effort. These findings demonstrate that lesion-guided ROI deep learning provides an effective balance between diagnostic performance and annotation efficiency, offering a practical approach for scalable AI-assisted ovarian ultrasound analysis

Comment
Submitted as a research article. The manuscript contains figures, tables, and supplementary material

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable Deep Learning Models for Breast Cancer Diagnosis Using Medical Imaging

cs.CV cs.AI ·2026-10-27 ·Sami Alnawali, Muhammad Atif Saeed, Abdul Hadi, Azka Atiq, Akhtar Jamil +1 more
benchmark similarity 0.72
Abstract · 37 page, 45 Figures

Deep learning shows promise for breast cancer diagnosis, but limited interpretability hinders clinical adoption. We benchmark ten ImageNet-pretrained models (ResNet50, VGG19, InceptionV3, DenseNet121, Xception, MobileNetV2, EfficientNet, ConvNeXt, ViT, and Swin Transformer) for benign-versus-malignant classification on the BreakHis histopathology dataset using a patient-level split, and explain their predictions with Grad-CAM, LIME, Integrated Gradients, and LRP. DenseNet121 performed best, with 99.4% test accuracy and an AUC-ROC of 0.999, and significantly outperformed all other models (p < 0.001). Transformer-based models trailed the CNNs. The explanations consistently highlighted nuclei-rich and glandular regions of diagnostic relevance. Combining transfer learning with explainable AI can thus yield accurate, interpretable tools for breast cancer diagnosis.

0.19

AppendiGrade: An XAI-Enhanced Deep Learning Framework for Grading Appendicitis in Ultrasound with Gaussian Blur and Grad-CAM

cs.CV cs.LG ·2026-08-18 ·Fahad Ahammed, Omar Faruq Shikdar, Navid Zaman, Md Tahsin, Md. Nawab Yousuf Ali +1 more
similarity 0.72
Abstract

Appendicitis is one of the most common abdominal emergencies worldwide and requires prompt diagnosis and treatment to prevent life-threatening conditions. However, accurately differentiating complicated cases, such as perforation or abscess formation, from uncomplicated appendicitis remains a significant clinical challenge. Among other methods, ultrasound is a safer and more cost-efficient diagnostic technique because of the lack of radiation exposure. In this research, an advanced system capable of automatically detecting complicated appendicitis from ultrasound images was developed. A dataset consisting of 4679 ultrasound images with 5 classes, namely perforated, abscess, acute, appendicolith, and normal, was used for the proposed model training and testing. Four pretrained deep learning models, DenseNet201, InceptionV3, ConvNextTiny, and VGG19, have been employed for detecting and classifying complicated appendicitis. In the initial configuration, InceptionV3 achieved the second highest accuracy, with a value of 69.21%. Owing to suboptimal performance with raw images, further optimization techniques, including image preprocessing, hyperparameter tuning, model fine-tuning, and image sharpening, were applied. These enhancements significantly improved the model's performance, with an accuracy of 95.58% for InceptionV3. The model performance is then explained with gradient-weighted class activation mapping (Grad-CAM), which creates a heatmap of the regions responsible for the model's prediction of the infected areas. This could make crosschecking with experts much easier.

0.25

Deep Learning-based Intelligent Diagnosis of Congenital Uterine Anomalies in 3D Ultrasound

cs.CV ·2026-09-14 ·Yueyue Xu, Yuhao Huang, Jiaxiao Deng, Yuanji Zhang, Haoming Zhang +9 more
published similarity 0.71
Abstract · 22 pages, 7 figures, 4 tables

Objective: To develop an intelligent framework, termed CUA-Net, for the automated classification of congenital uterine anomalies (CUA) without requiring coronal plane reconstruction, and to evaluate its clinical applicability. Methods: CUA-Net was built on 3D ResNet-18, equipped with a dynamic data resampling strategy to mitigate the data imbalance issue and a hard sample mining technique to fully learn from the difficult cases by loss adjustment. We further proposed the self-supervised reconstruction to comprehensively explore the volumes and the online data augmentation to refine the wrong predictions and enhance the model's generalization. We compared the CUA-Net with different deep-learning methods and junior/senior sonographers in the testing set. The evaluation metrics included accuracy, precision, recall, F1-score, micro-AUC, and macro-AUC. Results: The proposed CUA-Net exhibited satisfactory performance in both internal and external test sets. In the internal cohort, the model achieved accuracy of 93.88%, precision of 87.01%, recall of 95.92%, F1-score of 88.09%, and micro-AUC of 0.9982 and macro-AUC of 0.9997. In the external set, it maintained good performance with accuracy of 91.52%, precision of 83.27%, recall of 88.63%, F1-score of 81.49%, micro-AUC of 0.9945 and macro-AUC of 0.9990. Our CUA-Net outperformed the junior sonographers across all performance indicators and achieved performance comparable to that of the senior sonographers across most metrics. Conclusion: The CUA-Net demonstrates favorable accuracy and generalizability in classifying common CUA categories, while showing preliminary potential for recognizing less prevalent anomalies. These capabilities may help optimize clinical workflows and support more standardized diagnosis.

0.37

CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification

cs.CV cs.AI ·2026-08-14 ·Bingxin Yu, Xueli Wang, Jerry Zhou, Wenyan Wang, Li Wen +4 more
datasetcode/data similarity 0.70
Abstract

Ultrasound is the primary imaging modality for assessing thyroid nodules, and the ACR TI-RADS framework standardizes diagnosis through five ultrasound feature categories that are aggregated into five risk levels (TR1-TR5). Although widely adopted in clinical practice, most deep learning approaches focus on binary malignancy classification, while multi-class prediction and explicit utilization of feature-level supervision remain underexplored, largely due to limited annotated data. In this study, we introduce the STN dataset of 600 thyroid nodules with paired transverse and longitudinal ultrasound images, bounding box annotations, and complete labels for all five TI-RADS feature categories. Following the clinical decision process, we investigate how structured feature information can guide representation learning during training while requiring only images at inference. We demonstrate that text embeddings derived from standardized feature descriptions form a stable surrogate representation for TI-RADS risk levels. Based on this observation, we propose CMCNet, which aligns image embeddings to fixed textual embeddings via a Center-Margin Contrastive Loss that simultaneously promotes intra-class compactness and inter-class separation. Experimental results show that this embedding alignment strategy is more data-efficient and robust than direct multitask learning, and consistently outperforms InfoNCE, center loss, a strong multitask baseline, and a VQA-style multimodal model, particularly in imbalanced settings. The dataset is freely available at doi: 10.5281/zenodo.19125693 and the source code is available at: https://www.healthinformaticslab.org/supp/.

0.20

Comprehensive Benchmarking of Deep Learning Architectures for Lung Cancer Histopathology

cs.CV cs.AI ·2026-08-16 ·Hadi Hasan, Safaa Salman, Lama Sleem, Ralph Mouawad, Ali Chehab
benchmark similarity 0.69
Abstract · 8 pages

Lung cancer remains the leading cause of cancer-related mortality worldwide, while histopathological diagnosis is often affected by inter-observer variability and the substantial workload associated with manual slide examination. Although deep learning has shown considerable potential in computational pathology, comprehensive benchmarks that integrate tissue classification and region segmentation within a unified analytical framework remain limited. This study presents a two-stage deep learning framework for multi-class tissue classification and pixel-level histopathological region segmentation, accompanied by a systematic comparison of state-of-the-art architectures at each stage. For tissue classification, six models, a custom convolutional neural network, VGG16, DenseNet, MobileNetV3, a custom Vision Transformer, and YOLO11, are evaluated on a combined dataset of 39,000 images derived from LC25000 and LungHist700. The models distinguish between adenocarcinoma, squamous cell carcinoma, and normal lung tissue. YOLO11 achieves the best classification performance, with an accuracy of 98.38%, a five-fold cross-validation accuracy of 98.21 +/- 0.35%, and a macro F1-score of 0.98. For region segmentation, U-Net, ResNet-encoder U-Net, DeepLabV3+, and YOLO11-seg are evaluated using the GlaS gland segmentation benchmark. DeepLabV3+ obtains the highest Intersection over Union of 0.80 and a Dice score of 0.89, while YOLO11-seg achieves a comparable Intersection over Union of 0.79 using approximately 14x fewer parameters. The best-performing classification and segmentation models are subsequently integrated into an end-to-end framework, providing an accurate, computationally efficient, and reproducible baseline for automated histopathological image analysis.

0.40

How well do routinely collected demographic and clinical variables aid point-of-care lung ultrasound TB classification

eess.IV cs.CVcs.LG ·2026-10-05 ·Joshua M. Jansen van Vüren, Christiaan M. Geldenhuys, Devendra S. Parihar, Véronique Suttels, Trevor Brokowski +5 more
published similarity 0.69
Abstract · Accepted: SATNAC, Drakensberg, South Africa, 2026

We consider the fusion of lung ultrasound images with routinely-collected clinical and demographic data for the purpose of automated tuberculosis (TB) screening using deep-learning. Such deep-learning based screening tools for TB could meaningfully support the health care system in Africa, where the burden of disease is severe and resources are constrained. Beginning with an established ResNet baseline for classification of lung ultrasound images, which achieves an area under the receiver operating characteristic (AUROC) curve of 0.91 [0.86,0.96] (95% CI), we consider the incorporation of the clinical and demographic data using three fusion approaches. We find that a simple average-based fusion of the output scores of separately-trained image and clinical data classifiers consistently matches or outperforms a more complex approach where the data is fused earlier and a combined classifier is trained. Fusing the image and the clinical classifiers in this way leads to a classifier with an overall AUROC of 0.95 [0.91,0.99] (specificity of 0.76 at sensitivity 0.93) which is an improvement of 4% absolute over the image-only baseline. We also find that greedy feature selection can be used to reduce the number of clinical and demographic inputs without sacrificing classification performance. Finally, when we differentiate between clinical and demographic data that are self-reported, that require some basic measurement or calculation, and that require a point-of-care (POC) test, we find the inclusion of the POC tests included in this study to be of minimal benefit to classification performance. We conclude that the incorporation of routinely-collected clinical and demographic data is a promising way to improve the performance of lung ultrasound based automatic classification.

0.25

ProtoCAM: Interpretable Few-Shot Mask-Guided Prototypical Learning for Breast Lesion Classification in Ultrasound Imaging

cs.CV cs.AI ·2026-09-11 ·Ashkan Ebadi
similarity 0.69
Abstract · 11 pages, 3 figures

Breast ultrasound imaging plays an important role in the early detection and diagnosis of breast cancer, particularly for patients with dense breast tissue. However, developing reliable deep learning models for ultrasound analysis is challenging due to limited annotated medical data and the need for interpretable predictions. To address these challenges, this paper proposes ProtoCAM, an explainable few-shot learning framework for breast lesion classification that integrates mask-guided feature encoding, prototypical metric learning, and gradient-based visual explanations. The proposed approach leverages lesion masks to guide feature extraction and constructs class prototypes within an embedding space to enable robust classification under limited training samples. The framework was evaluated on the BUSI dataset using a stratified group k-fold cross-validation protocol to prevent patient-level data leakage. Experimental results demonstrate ProtoCAM's high performance in low-data scenarios. In a 3-way 5-shot setting, the proposed method achieves a macro F1-score of 0.910, representing a substantial improvement over standard supervised CNN models. Among the evaluated backbone networks, ResNet18 achieved the best performance, reaching a macro F1-score of 91.65% under a 15-shot configuration, providing interpretable insights into the classification decisions. These results highlight the potential of explainable few-shot learning frameworks for reliable computer-aided breast cancer diagnosis in data-scarce medical imaging environments.

0.10

Architecture-aware Robustness Evaluation of Explainable Deep Learning for Breast Cancer Diagnosis

cs.CV ·2026-09-18 ·Balenthira Thanusanth, Selvarajah Thuseethan, Roshan G. Ragel, Bimali S. Weerakoon, Ayesh Jayasinghe +1 more
code/data similarity 0.69
Abstract · 12 pages, 7 figures

Explainable Artificial Intelligence (XAI) has become essential in medical image analysis to ensure transparency of deep learning (DL)-based diagnostic systems. However, selecting appropriate XAI techniques for breast cancer recognition remains largely ad hoc, with limited systematic evaluation across different DL architectures. This study presents a systematic architecture-aware evaluation protocol to assess the effectiveness of nine widely used XAI techniques across four categories of DL models: very deep, lightweight, transformer-based and hybrid neural networks. The evaluation is conducted on a breast ultrasound dataset comprising 780 images using clinically aligned spatial metrics, including Pointing Game, Intersection over Union and Mean Coverage, to quantify agreement between generated explanations and expert-annotated lesion regions. Results indicate that explanation quality is primarily influenced by the interaction between model architecture and XAI method, rather than any single technique consistently outperforming others. Hybrid architectures produce more spatially coherent explanations, while lightweight and transformer-based models exhibit greater variability across methods. The findings show that no single technique generalises across architectures and evaluation criteria, emphasising the need for joint selection of DL models and XAI techniques. Explainability depends on both model design and explanation strategy and should not be considered independently. This work provides a structured evaluation protocol and practical guidance for selecting XAI techniques in breast cancer diagnosis, supporting more transparent clinical decision-support systems. \textcolor{blue}{Code is publicly available at https://github.com/Nishan-Charlie/Explainable-AI}

0.29