Do Saliency Maps Fail Dense Breasts? A Chance-Normalized, Confounder-Aware Audit of Explanation Fairness in Mammography

Ahmed Jaheen

cs.CV cs.AI ·submitted 2026-11-04 04:01 UTC · v1

Abstract

Saliency maps, offered as evidence that mammography classifiers use the cancer, are untested in dense breasts, which can hide cancers. We tested whether they locate cancers worse there, and why. On 1,345 malignant CBIS-DDSM views, we scored three CNNs' Grad-CAM, Integrated Gradients and occlusion maps by whether their peak hits the lesion and a chance-normalized lesion-to-background saliency ratio (bits; +1 doubles it). Unadjusted gaps were large: Grad-CAM peaks hit 44% of dense vs. 58% of non-dense lesions. Case mix, chiefly more calcifications in dense breasts, explained about half or more of each gap. Occlusion kept a significant average of -0.56 bit gap. Controls also implicate the classifiers: unadjusted gaps exceeded an image-only conspicuity map's, and models relied less on dense-breast lesions. We recommend reporting density gaps before and after case-mix adjustment, per classifier, with conspicuity and lesion-reliance controls.

Closest papers

Nearest neighbours by meaning across the whole index.

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.68
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31

Faithful Faithfulness Evaluations: Challenges & Pitfalls Learned from a Breast MRI Case Study

cs.CV cs.HCcs.LGeess.IV ·2026-09-22 ·Peachapong Poolpol, Henrik H. J. Detjen, Eike Petersen
published similarity 0.66
Abstract · Accepted at MICCAI iMIMIC Workshop 2026

Saliency maps are widely used to explain deep learning predictions in medical imaging, yet visually plausible explanations do not necessarily reflect a model's true decision process and may therefore mislead clinicians. We investigate this problem using a Vision Transformer-based breast MRI classifier trained on the ODELIA Breast MRI Challenge dataset and evaluate multiple saliency methods, including Last-layer Attention, Attention Rollout, Grad-SAM, Gradient Attention Rollout, GMAR, Grad-CAM, and HiResCAM. Our study highlights two often-overlooked challenges in perturbation-based faithfulness evaluation. First, method rankings depend strongly on the perturbation strategy, varying across intensity-based perturbations and transformer-based attention masking. Second, benchmarking saliency methods requires distinguishing between class-specific and class-agnostic explanations. To enable fair comparisons, we introduce non-class-specific variants of gradient-based methods and evaluate both settings separately. Across protocols, Grad-CAM and Gradient Attention Rollout consistently emerged as the strongest class-specific methods, although their relative ranking depended on the evaluation design. These findings expose important limitations of current saliency-based explainability approaches and highlight the need for more robust and standardized evaluation frameworks for trustworthy clinical AI systems.

0.28

Healthy Counterfactual Generation via Diffusion Inpainting for Mammography Classification

cs.CV ·2026-10-08 ·Inês Cruchinho Garcia, Mariana Mourão, Francisco Maria Calisto, Carlos Santiago, Jacinto Nascimento
publishedcode/data similarity 0.65
Abstract · Accepted at MICCAI Workshop Deep-Brea3th 2026

False negatives remain a critical limitation of computer-aided diagnosis (CAD) systems for breast cancer screening due to delayed detection and treatment. To address this issue, we propose a counterfactual data augmentation strategy that generates healthy mammograms by "erasing" lesions from anomalous images, thereby enriching the training distribution. We train a Denoising Diffusion Probabilistic Model on BI-RADS 1 (healthy) mammograms and use a RePaint-based sampling strategy to inpaint realistic normal tissue within annotated lesion bounding boxes. The resulting healthy counterfactuals replace annotated lesion regions with realistic healthy tissue while preserving patient-specific anatomical structure, as supported by similarity metrics between real and generated images. Image realism was further assessed by radiologists and found to be consistent with the original dataset quality. We evaluate counterfactual augmentation across four representative classifier architectures: a convolutional neural network (ConvNeXt), a vision transformer (ViT), a vision-language model pre-trained on mammogram-report pairs (Mammo-CLIP) and a multi-scale attention-based multiple-instance learning framework (FPN-MIL). Experiments conducted on the VinDr-Mammo dataset show improvements in sensitivity across all architectures, particularly at 80\% fixed specificity, contributing towards more reliable CAD systems for breast cancer. Code is available at: https://github.com/ines03garcia/diffusion-based-counterfactual-generation.

0.33

Bilateral Evidence Selection and Reasoning for Mammography Vision--Language Models

cs.CV cs.AI ·2026-11-19 ·Zhengbo Zhou, Dooman Arefan, Shandong Wu
similarity 0.64
Abstract

Medical vision--language models (VLMs) often need to identify small, subtle lesions within high-resolution images containing extensive normal anatomy and redundant visual information. Visual-token compression improves efficiency, but preserving salient regions alone can discard the context needed for diagnostic interpretation. This context can extend across images: in bilateral mammography, the opposite breast provides a patient-specific anatomical reference. Yet retaining such evidence does not ensure that the model uses it effectively. We propose Bilateral Evidence Selection and Reasoning (BESR), which connects evidence preservation with comparative assessment through a bilateral-guided token selector and a bilateral reward. Under a shared token budget, the selector jointly prioritizes lesion appearance and its local and bilateral context, while the reward encourages assessments that benefit from the preserved comparison. Experiments on a bilateral dataset constructed from CBIS-DDSM and on VinDr-Mammo demonstrate improved evidence retention and diagnostic performance under constrained visual-token budgets. Inference benchmarking further shows reduced prefill latency.

0.30

MammoMix: Leveraging Mixture of Experts for Robust Mammogram Breast Detection

cs.CV ·2026-08-11 ·Dinh Tan Nguyen, Hoang Quan Dang, Chen Zhang, Sai Ho Ling
published similarity 0.62
Abstract · Australasian Joint Conference on Artificial Intelligence 2025

Breast lesion detection in mammography remains a challenging task due to variations in image quality, lesion appearance, and population demographics across datasets. While current object detectors such as YOLO and DETR achieve strong results on individual datasets, their performance often degrades when trained on or applied across heterogeneous sources. To address this, we propose MammoMix, a novel framework based on Mixture-of-Experts (MoE) paradigm for robust and generalizable lesion detection. In MammoMix, each expert model is trained on a specific domain, allowing it to specialize in distinct characteristics of its source data. A gating mechanism adaptively weighs contributions from each expert based on input image, combining their outputs to enable domain-adaptive inference. To improve reliability, we further incorporate a calibration module, MoCAE, which adjusts confidence scores to reflect true predictive uncertainty. We evaluate MammoMix on 3 public mammography datasets: CSAW, DDSM, and DMID, covering diverse clinical settings. Results show that MammoMix outperforms baseline detectors in both average precision and reliability, particularly on datasets with greater variability. Our findings demonstrate that expert specialization and calibrated ensemble fusion significantly enhance model generalization and robustness. MammoMix offers a promising step toward dependable AI-assisted breast cancer screening across real-world clinical domains.

0.52

MammoSeek: A Mammography Agent with selective zooming for grounded reports

cs.CV ·2026-11-04 ·Haoyan Ding, Qian Wang, Lixia Wang, Debiao Li
similarity 0.62
Abstract · 5 pages, 2 figures

Radiologists read a screening mammogram by first forming a global impression of the four views and then selectively magnifying suspicious regions before assigning a BI-RADS assessment. MLLMs, in contrast, see the whole image at a fixed, reduced resolution, which makes sub-millimeter calcifications invisible, and they perform close to chance on mammography. Therefore, we present MammoSeek, a mammography agent that reproduces this reading process. After forming an impression of each breast, the agent performs selective zooming: it decides by itself which detector candidates deserve a closer look and inspects only those on full-resolution views. Guided by a BI-RADS assessment skill, it then assigns a category and generates a localized, lexicon-structured report for each breast; its assessment is combined with image-model scores in a decision layer to decide recall. On an internal (EMBED) and an external (VinDr-Mammo) dataset, \ours reaches exam-level AUCs of 0.824 and 0.818, far above other MLLMs, mammography agent and CNN classifiers. Selective zooming also outperforms both no zooming and forced zooming in localization, structured-report F1 and recall decisions at low cost.

0.29

From Density to Biopsy Decisions and Malignancy Prediction: A Benchmark Study of Multimodal Large Language Models Against Radiologists in Digital and Contrast-Enhanced Mammography

cs.CV physics.med-ph ·2026-09-13 ·Ali Abbasian Ardakani, Afshin Mohammadi, Taha Yusuf Kuzan, Beyza Nur Kuzan, Alisa Mohebbi +9 more
benchmark similarity 0.62
Abstract · 37 pages, 6 figures, 5 tables

Purpose: To compare four multimodal large language models (MLLMs) with radiologists of varying expertise in breast density assessment, BI-RADS assessment, biopsy candidacy determination, and continuous malignancy probability estimation using digital mammography (DM) and contrast-enhanced mammography (CEM). Methods: This study included 179 women with paired DM/CEM examinations and reference standards. Four MLLMs (ChatGPT-5.2, Gemini-3.1 Pro, Sonnet-4.6, Muse Spark) interpreted images with and without masks; three radiologists interpreted non-masked images. Results: For binary density classification on DM, radiologist accuracies ranged from 55.81% to 78.60%, exceeding most MLLM values (62.33%-71.63%), while masks added limited benefit. Five-category BI-RADS accuracies were higher for radiologists on DM (56.74-67.44%) and CEM (62.33-82.79%) compared with MLLMs (DM 31.16-45.12%; CEM 40.00-55.81%). Binary biopsy-candidacy accuracies were likewise higher for radiologists (DM 85.12-89.77%; CEM 86.98-92.09%) than for MLLMs (DM 61.39-75.35%; CEM 69.30-82.79%), although CEM improved performance across all readers. Lesion masks substantially improved MLLM continuous malignancy-probability accuracies from 64.65%-71.63% to 72.56-78.60% on DM and from 67.91%-77.21% to 72.56%-81.86% on CEM, approaching radiologist ranges (DM 63.72-82.79%; CEM 81.86-88.84%). The corresponding AUCs for the top masked models overlapped those of the human readers. Overall, Muse Spark, followed by Sonnet-4.6, demonstrated the strongest performance among the MLLMs across domains. Conclusion: Radiologists generally outperformed MLLMs in categorical tasks, while selected masked models approached human performance for continuous malignancy probability estimation, suggesting a potential adjunctive role.

0.50

A Lightweight Attention-Based CNN with Saliency-Map Interpretability for Skin Cancer Detection

cs.CV cs.AI ·2026-10-27 ·Sanjana Islam Kasfia, Md. Ismiel Hossen Abir, AKM Bahalul Haque, Abir Mahmud Shahariar
similarity 0.62
Abstract

Skin cancer is among the most prevalent and life threatening forms of cancer worldwide. Early and accurate diagnosis significantly improves patient survival rates. However, manual dermoscopic assessment remains challenging due to visual similarity. This study proposes an Explainable AI-driven framework for automated binary classification of skin lesions using a lightweight attention-based convolutional neural network (CNN-Attention). The model integrates channel attention to focus on informative regions of dermoscopic images while maintaining low computational complexity. A publicly available dataset comprising 2,637 training and 660 test images was used, with balanced class weights. The proposed model achieved 87 percent accuracy with 1.95 million parameters and 7.45 MB of storage, matching the best baseline (MobileNet) while using approximately half as many parameters and half as much storage. ROC AUC and PR AUC scores reached 0.9475 and 0.9430, respectively. Additionally, saliency maps were incorporated as an explainability technique to visualize regions that influence model decisions. Comparative analysis with VGG16,VGG19,ResNet101,and MobileNet demonstrates the proposed models effectiveness in balancing classification results, computational efficiency, and interpretability.

0.09