Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case Study

Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala

cs.CV cs.LG ·submitted 2026-09-29 15:42 UTC · v1
benchmark

Abstract

Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even when it depends strongly on how the benchmark was evaluated. We study this problem on the widely used Kermany pediatric chest radiograph dataset using nine image classifiers and a controlled evaluation protocol. Under the same protocol, the eight pretrained backbones differ by only 0.026 AUROC. In contrast, changing whether the backbone is frozen or fine-tuned changes AUROC by 0.044 on average, and changing the decision threshold changes balanced accuracy by 0.090 on average. The official test split is also measurably different from the training pool: a partition classifier distinguishes them at AUC 0.697, rising to 0.898 for normal radiographs. Most strikingly, a classifier using only file properties, with no image anatomy, reaches 0.992 balanced accuracy within the training pool but falls to 0.496 on the official test split. Validation-fitted thresholds and calibration also transfer imperfectly. These results show that a high benchmark score can support different conclusions when the split, training policy, threshold, metric, calibration, and uncertainty are not communicated with it. We end with a seven-item reporting recommendation in which each item is tied to an effect measured in the study

Closest papers

Nearest neighbours by meaning across the whole index.

On Cross-Validation for Hyperparameter Optimization of Deep Learning Image Classifiers

cs.CV cs.LG ·2026-08-10 ·Ljubomir Buturovic
similarity 0.71
Abstract

Hyperparameter optimization (HPO) can materially affect the performance of deep learning (DL) image classifiers, but there is little empirical guidance on how to derive the validation signal that drives it, especially for the small sample sizes common in fields such as medical imaging. We compared three HPO protocols in terms of {\em absolute performance-estimation error} (AEE; the absolute difference between the winning configuration's validation AUROC and its test AUROC): fixed holdout (F), reshuffled holdout (R), and 5-fold cross-validation (C). The search space, sampler, training procedure, architecture, and test set were held identical across protocols. We evaluated the protocols on three public datasets spanning two regimes: binary medical imaging (RSNA pneumonia radiographs and binarized HAM10000 skin lesions) and 200-class natural imaging (Tiny ImageNet), across a range of development set sizes $n$ and two backbones (ResNet-18 on all datasets, Vision Transformer (ViT-S/16) on RSNA). On the medical datasets, every point estimate favored cross-validation over both holdout protocols, with reductions in AEE largest at small sample sizes and diminishing as $n$ increased. This pattern remained robust under conservative family-wise adjustment. On Tiny ImageNet, AEE was negligible under all three protocols. Test AUROC was generally similar among protocols. Fixed holdout had lower mean AEE than reshuffled holdout in 11 of 12 medical conditions, although this secondary finding was less uniformly supported. For small-sample medical image classification, we recommend cross-validation-based HPO when computational resources permit because it trades additional computation for a more reliable development-time estimate of subsequent test performance.

0.04

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.69
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.18

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.69
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/data similarity 0.69
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38

From Adults to Children: Benchmarking Foundation Models for Chest X-Ray Classification under Domain Shift

cs.CV ·2026-10-15 ·Sara Inácio, Hugo Proença, João C. Neves
publishedbenchmark similarity 0.69
Abstract · Accepted at WACV 2027

Foundation models have shown significant potential across diverse fields and have been applied to medical imaging, but their robustness across patient populations remains unclear. In this work, we investigate foundation models' ability to generalize from adult to pediatric chest X-ray classification. To the best of our knowledge, this is the first benchmark to compare multiple foundation models under a common adult-to-pediatric evaluation setting while also analyzing the effect of adaptation depth. We harmonize VinDr-CXR and PediCXR into a five-label classification task and evaluate six foundation models and two CNN baselines. All models are adapted using adult data only and tested in both the in-domain and pediatric domains using linear probing, partial fine-tuning, and full fine-tuning. The benchmark reveals a clear and consistent trend: all models suffer a substantial performance degradation when transferred from adult to pediatric data, with drops exceeding 10 percentage points. While Macro-AUROC values reach approximately 92% on the adult test set, performance decreases to around 78% on the pediatric domain. Another important finding is that increasing the depth of adaptation improves pediatric performance on average, although the effect varies across models. Moreover, strong in-domain performance does not necessarily indicate greater robustness to domain shift.

0.40

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

cs.CV ·2026-10-14 ·Patrick Wienholt, Frederik Hauke, Christiane Kuhl, Jakob Nikolas Kather, Sven Nebelung +1 more
code/data similarity 0.68
Abstract · 29 pages (18 pages main text, 11 pages Supplementary Information), 5 figures, 3 tables

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration

0.45

Extending the Horizon of Early Diagnosis: Lung Cancer Prediction with Vision Transformers

cs.CV ·2026-08-21 ·Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson +9 more
similarity 0.66
Abstract

Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage malignancies can be subtle on chest X-rays, creating challenges for radiologists. This study evaluates Vision Transformers (ViTs) for predicting lung cancer one to two years before clinical diagnosis. We analyzed 259,361 chest X-rays from 91,020 imaging studies at the Jamaica Plains VA Hospital in Boston, MA. The dataset showed extreme class imbalance, approximately 1:150 cancer to non-cancer, which was addressed using hybrid under- and over-sampling and class-weighted loss optimization. Three ViT configurations were evaluated: a model trained from scratch, an ImageNet-pretrained model, and a Corona-pretrained model fine-tuned on the lung cancer dataset. Transfer learning improved performance, with pretrained models exceeding the scratch baseline by 6-10 percentage points in AUC and about 10-12 percent in balanced accuracy. ImageNet-pretrained models showed the most stable overall performance, while Corona-pretrained models achieved higher sensitivity in some settings but greater variability. Moderate resampling ratios, including 1:1 undersampling and 1.5:2 oversampling, provided favorable trade-offs between sensitivity, precision, and computational efficiency, reducing runtime by up to 70 percent without major performance loss. These findings demonstrate the potential of ViTs for early lung cancer risk prediction from routine chest X-rays. Although performance remains below clinical deployment thresholds, the results support further development of ViT-based triage systems to flag high-risk patients for earlier evaluation.

0.09

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.65
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31