CS Paper Radar

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

Patrick Wienholt, Frederik Hauke, Christiane Kuhl, Jakob Nikolas Kather, Sven Nebelung, Daniel Truhn

cs.CV ·submitted 2026-10-14 13:53 UTC · v1
code/data

Abstract

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration

Comment
29 pages (18 pages main text, 11 pages Supplementary Information), 5 figures, 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Can Multimodal Decision Models Classify Breast Ultrasound Images? Benchmarking CLEF and CLEF-Flash Across Prompts and Datasets

eess.IV cs.CV ·2026-10-09 ·Tran Cao Minh, Hai Tran, Ha Minh Tan
similarity 0.72
Abstract

Multimodal decision models return probabilities over predefined alternatives, offering a structured interface for image classification. This study benchmarks inference with CLEF and CLEF-Flash on 2818 breast ultrasound images from Dataset B, BUSI, and BUS-BRA. Dataset B and BUS-BRA use binary benign-malignant classification, whereas BUSI includes normal, benign, and malignant categories. Model parameters remain unchanged, and original images are submitted without user-defined preprocessing. Three prompts provide minimal labels, an explicit classification task, or sonographic criteria. We report accuracy, macro F1, balanced accuracy, macro precision, throughput, and latency. CLEF-Flash with the clinical prompt achieves the highest accuracy on all three datasets: 74.85% on Dataset B, 66.28% on BUSI, and 51.63% on BUS-BRA. On BUSI, however, CLEF with the task-guided prompt achieves the highest macro F1 (64.51%) and balanced accuracy (68.72%). CLEF-Flash has lower latency in every matched comparison. Clinical instructions improve CLEF-Flash accuracy relative to the minimal prompt but reduce CLEF accuracy on all datasets. Confusion matrices reveal frequent benign-to-malignant errors, particularly on BUS-BRA, where all configurations fall below the 67.63% accuracy of a majority-class predictor. These findings demonstrate dataset-and prompt-dependent performance and motivate class-specific evaluation before applying multimodal decision models to breast ultrasound analysis.

0.52

Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case Study

cs.CV cs.LG ·2026-09-29 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.68
Abstract

Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even when it depends strongly on how the benchmark was evaluated. We study this problem on the widely used Kermany pediatric chest radiograph dataset using nine image classifiers and a controlled evaluation protocol. Under the same protocol, the eight pretrained backbones differ by only 0.026 AUROC. In contrast, changing whether the backbone is frozen or fine-tuned changes AUROC by 0.044 on average, and changing the decision threshold changes balanced accuracy by 0.090 on average. The official test split is also measurably different from the training pool: a partition classifier distinguishes them at AUC 0.697, rising to 0.898 for normal radiographs. Most strikingly, a classifier using only file properties, with no image anatomy, reaches 0.992 balanced accuracy within the training pool but falls to 0.496 on the official test split. Validation-fitted thresholds and calibration also transfer imperfectly. These results show that a high benchmark score can support different conclusions when the split, training policy, threshold, metric, calibration, and uncertainty are not communicated with it. We end with a seven-item reporting recommendation in which each item is tied to an effect measured in the study

0.11

MedUAG: Unified Understanding and Generation for Medical Multimodal Models

cs.CL cs.AI ·2026-08-19 ·Zijie Meng, Yuncheng Zhang, Hualiang Wang, Yitian Tang, Xiaotang Gai +6 more
benchmark similarity 0.67
Abstract

Recent Multimodal Large Language Models (MLLMs) are rapidly evolving into unified understanding and generation (UAG) frameworks. However, extending these unified paradigms to the medical domain is hindered by: the absence of comprehensive training and evaluation benchmarks, and the lack of broadly validated unified medical model. To address these gaps, we present a comprehensive foundation for medical UAG. First, we construct MedUAGCorpus, the largest unified medical understanding and generation dataset to date, comprising over 6 million instances across 14 imaging modalities. Second, we introduce MedUAGBench, a systematic benchmark that expands medical generation evaluation to 12 diverse tasks under standardized protocols. Finally, leveraging these resources, we develop MedUAG, an end-to-end trained unified medical model. Extensive experiments demonstrate that MedUAG achieves strong performance across a wide array of understanding and generation tasks, establishing a competitive baseline and paving the way for next-generation medical multimodal systems.

0.21

MedJev: A System One Vision-Language Decision Model for Fast and Effective Medical Image Understanding

cs.CV ·2026-11-16 ·Fan Zhang, Hao Wu, Jinyang Wu, Hongyu Qu, Zheng Lian +3 more
similarity 0.67
Abstract

Medical image understanding with vision-language models (VLMs) typically relies on autoregressively generating reasoning and answer tokens. These unnecessary tokens make the inference cost scale with the response length and force the answer to be parsed from free-form text, incurring avoidable latency and decision errors. To this end, we introduce \textsc{MedJev}, a \emph{system one} vision-language decision model that maps medical images, questions, and candidate answers directly to decisions in a single multimodal forward pass, without any autoregressive generation process. For fast inference, \textsc{MedJev} removes the upper language layers and the generative output pathway, while keeping the full vision pathway and all visual tokens. On this shortened backbone, a decision head scores each candidate by pretrained query--key matching and refines the scores with a lightweight multilayer perceptron (MLP) residual, coupling the pretrained matching structure with task-specific nonlinear discrimination. Built on Qwen3.5-4B, \textsc{MedJev}-4B improves both accuracy and speed over the original model on each of four medical image classification and visual question answering benchmarks, with an absolute accuracy gain of \textbf{7.93\%} and a \textbf{6.04$\times$} end-to-end speedup. Further comparison with 20 cutting-edge models shows that \textsc{MedJev}-4B achieves state-of-the-art performance and inference speed among 4B--9B general and medical VLMs, indicating that direct multimodal decision making is an effective route to fast and effective medical image understanding.

0.47

Multimodal Medical Image Parsing with Task-Specific Low-Rank Adapters

cs.CV cs.AIcs.LG ·2026-10-14 ·Taha Sabir, Alberto Montero Molina, Thinh Quang Ly, Veronika Dmitrenko, Mohammad Yaqub +1 more
code/data similarity 0.67
Abstract · 17 pages, 4 figures. FLARE 2026 Task 3 methodology paper (2D track)

Adapting a single vision-language model to medical image parsing requires training choices that reflect the demands of each task. We study task-specific adaptation with Qwen3.5-9B for FLARE 2026 Task 3, covering six task families and seven imaging modalities. Our system couples a shared, frozen 4-bit backbone with LoRA adapters selected from the input question. We customize adapter ranks and prompts, rebalance rare classification targets, and supplement regression training with dermatology classification examples. On the fixed internal holdout, the task-specific adapters achieve a dataset-macro balanced accuracy of 0.7791 for classification, a dataset-macro micro-F1 of 0.6286 for multi-label classification, a counting mean absolute error (MAE) of 11.73, a dataset-macro detection F1 of 0.8914, a dataset-macro regression MAE of 9.78, and a report-generation CRIMSON score of 0.8204. On the organizer's 1,703-example hidden-validation set, the submitted system achieves 0.8496 classification balanced accuracy, 0.5338 sample-averaged multi-label F1, and 14.5950 regression MAE. The final 30.1 GB container averages 3.1 seconds per case, including model loading, and produces identical outputs across repeated verification runs. The benefits vary across tasks, supporting the use of task-specific adapter configurations and image budgets within a shared medical vision-language model. Code is available at https://github.com/TahaSabir0/FLARE26-Hexapus.

0.27

MedReaMM: Evaluating Large Multimodal Models on Expert-Level Clinical Diagnostic Synthesis

cs.CV ·2026-08-23 ·Lai Wei, Yuchao Chen, Zhenbiao Cao, Xiaojin Zhang, Zhongyu Wei +3 more
top venuebenchmark similarity 0.67
Abstract

The application of Large Language Models (LLMs) to diagnostic decision-making has garnered growing interest. However, existing benchmarks largely focus on textual reasoning or isolated visual question-answering (VQA) tasks, lacking holistic integration of clinical narratives and medical imaging, and thus failing to assess the multimodal diagnostic synthesis capability central to expert clinical judgment. To bridge this gap, we introduce MedReaMM, a benchmark specifically designed to evaluate models' ability to synthesize heterogeneous clinical evidence consisting of detailed patient histories alongside multiple medical images into accurate differential diagnoses under a complete-information paradigm. Constructed from case reports sourced from top-tier medical journals and curated clinical case databases, MedReaMM comprises 625 expert-validated cases with an average of 2.79 medical images per case and a total of 1,042 standardized diagnoses annotated with ICD-11 codes. These cases predominantly represent rare, atypical, or multi-system presentations that demand expert-level evidence integration beyond routine pattern recognition. We evaluate 23 Large Multimodal Models (LMMs) and find that most achieve diagnostic accuracy scores below 50%, underscoring a substantial gap in multimodal diagnostic synthesis capability. Further analysis reveals that medical knowledge proficiency, medical image understanding, and evidence integration are all highly correlated with diagnostic performance.

0.40

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.66
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.18

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

cs.CV ·2026-08-26 ·Juan Iñaki Larrea, Lucas Mansilla, Enzo Ferrante
published similarity 0.66
Abstract · Accepted at MIRASOL Workshop, MICCAI 2026. 10 pages, 3 figures

Foundation models are increasingly deployed for medical image analysis. However, under the inter-institutional distribution shift typical of deployment, their performance varies widely and cannot be known without target-domain labels, which are rarely available. This leaves a practical question unresolved: given several candidate foundational models and labeled-data from a source domain, which one to deploy in an unlabeled target domain? We propose a label-free selection criterion built on SUDO, a framework for evaluating clinical AI systems without ground-truth annotations. SUDO partitions the unlabeled target data by predicted probability and, for each region, measures a pseudo-label discrepancy reflecting class contamination; aggregated across regions, this yields a score (AURCC) requiring neither target annotation nor fine-tuning. We show that AURCC can be used to rank a variety of vision-language models (BioMedCLIP, CXR-CLIP, CheXzero, MedCLIP, MedImageInsight, CLIP) on chest X-ray classification across three inter-hospital shift scenarios, under zero-shot and MLP-probe regimes. The AURCC ranking recovers the ground-truth ranking with Spearman rho up to 0.943 (p<0.05). Against the natural baseline of ranking by held-out source accuracy, AURCC is competitive when the labeled source is large and yields a more accurate ranking once it is small; the regime of interest in resource-constrained settings.

0.19