CS Paper Radar

Multimodal Medical Image Parsing with Task-Specific Low-Rank Adapters

Taha Sabir, Alberto Montero Molina, Thinh Quang Ly, Veronika Dmitrenko, Mohammad Yaqub, Tausifa Jan Saleem

cs.CV cs.AIcs.LG ·submitted 2026-10-14 09:59 UTC · v1
code/data

Abstract

Adapting a single vision-language model to medical image parsing requires training choices that reflect the demands of each task. We study task-specific adaptation with Qwen3.5-9B for FLARE 2026 Task 3, covering six task families and seven imaging modalities. Our system couples a shared, frozen 4-bit backbone with LoRA adapters selected from the input question. We customize adapter ranks and prompts, rebalance rare classification targets, and supplement regression training with dermatology classification examples. On the fixed internal holdout, the task-specific adapters achieve a dataset-macro balanced accuracy of 0.7791 for classification, a dataset-macro micro-F1 of 0.6286 for multi-label classification, a counting mean absolute error (MAE) of 11.73, a dataset-macro detection F1 of 0.8914, a dataset-macro regression MAE of 9.78, and a report-generation CRIMSON score of 0.8204. On the organizer's 1,703-example hidden-validation set, the submitted system achieves 0.8496 classification balanced accuracy, 0.5338 sample-averaged multi-label F1, and 14.5950 regression MAE. The final 30.1 GB container averages 3.1 seconds per case, including model loading, and produces identical outputs across repeated verification runs. The benefits vary across tasks, supporting the use of task-specific adapter configurations and image budgets within a shared medical vision-language model. Code is available at https://github.com/TahaSabir0/FLARE26-Hexapus.

Comment
17 pages, 4 figures. FLARE 2026 Task 3 methodology paper (2D track)

Closest papers

Nearest neighbours by meaning across the whole index.

Two-Stage Mixture-of-LoRA for Multi-Task Medical Vision-Language Learning

cs.CV ·2026-09-13 ·Zhanghao Chen, Yuanyuan Li, Zhenyu Lu, Shuo Gao, Guangquan Zhou +1 more
publishedcode/data similarity 0.76
Abstract · MICCAI FLARE26 Task3 Challenge Report, 18 pages, 6 figures

Medical vision-language models (VLMs) allow a single model to perform clinical image analysis tasks ranging from diagnosis classification to report generation. However, joint adaptation is challenged by heterogeneous output formats, conflicting task gradients, and imbalanced training data. Hence, we present \textbf{Two-Stage Mixture-of-LoRA}, a framework built on MedGemma-1.5-4B. The framework uses a shared-specific Mixture-of-LoRA architecture comprising one shared LoRA and six task-specific expert LoRAs, together with a two-stage training procedure. In Stage 1, we jointly train the shared LoRA and all task-specific expert LoRAs on all tasks. In Stage 2, we first freeze the backbone, the shared LoRA, and all non-target experts, and refine one task expert at a time. Classification and regression then receive an additional modality-balanced continuation, in which smaller modality groups are repeated to match the largest group. In the FLARE 2026 Task 3 test sets, the proposed method achieves 0.85 balanced accuracy for classification, 0.48 micro-F1 for multi-label classification, 0.79 detection F1, and 17.39 regression MAE. Code is available at https://github.com/YuanYL03/MICCAI-FLARE-2026-Challenge-Task3-2D.

0.45

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

cs.CV ·2026-10-14 ·Patrick Wienholt, Frederik Hauke, Christiane Kuhl, Jakob Nikolas Kather, Sven Nebelung +1 more
code/data similarity 0.67
Abstract · 29 pages (18 pages main text, 11 pages Supplementary Information), 5 figures, 3 tables

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration

0.46

MI-Hyper: Generating Multiple Instance Models for Weight Space Transfer Learning in Histopathology via Mixed Tasks Pretrained HyperNetwork

cs.CV ·2026-11-17 ·Xitong Ling, Yousef Kotp, Weiming Chen, Yining Li, Jiawen Li +7 more
similarity 0.66
Abstract

Zero-shot whole-slide image (WSI) prediction aims to generalize to new pathology tasks without parameter updates at deployment. MI-Zero makes these predictions by pooling patch-text similarities. Conditional weight generation, combined with supervision from diverse pathology tasks, offers an alternative: learning to construct predictive rules from task descriptions. We introduce MI-Hyper, a hypernetwork pretrained across mixed tasks to generate the aggregation and classification weights of multiple instance learning (MIL) models. We first train the generator and a shared MIL basis jointly using source labels. We then freeze the basis and refine the generator. The generated task weights are reused across cases. Across 308 tasks from 52 pathology datasets, MI-Hyper improves mean AUC, balanced accuracy and macro-F1 over MI-Zero by 1.85, 1.17 and 0.57 percentage points, respectively. On some molecular prediction tasks, both AUC and balanced accuracy improve by more than 20 points. These results support task-conditioned weight generation as a promising approach to weight-space transfer for long-sequence modeling.

0.17

MedJev: A System One Vision-Language Decision Model for Fast and Effective Medical Image Understanding

cs.CV ·2026-11-16 ·Fan Zhang, Hao Wu, Jinyang Wu, Hongyu Qu, Zheng Lian +3 more
similarity 0.65
Abstract

Medical image understanding with vision-language models (VLMs) typically relies on autoregressively generating reasoning and answer tokens. These unnecessary tokens make the inference cost scale with the response length and force the answer to be parsed from free-form text, incurring avoidable latency and decision errors. To this end, we introduce \textsc{MedJev}, a \emph{system one} vision-language decision model that maps medical images, questions, and candidate answers directly to decisions in a single multimodal forward pass, without any autoregressive generation process. For fast inference, \textsc{MedJev} removes the upper language layers and the generative output pathway, while keeping the full vision pathway and all visual tokens. On this shortened backbone, a decision head scores each candidate by pretrained query--key matching and refines the scores with a lightweight multilayer perceptron (MLP) residual, coupling the pretrained matching structure with task-specific nonlinear discrimination. Built on Qwen3.5-4B, \textsc{MedJev}-4B improves both accuracy and speed over the original model on each of four medical image classification and visual question answering benchmarks, with an absolute accuracy gain of \textbf{7.93\%} and a \textbf{6.04$\times$} end-to-end speedup. Further comparison with 20 cutting-edge models shows that \textsc{MedJev}-4B achieves state-of-the-art performance and inference speed among 4B--9B general and medical VLMs, indicating that direct multimodal decision making is an effective route to fast and effective medical image understanding.

0.47

ViCoR: Estimating Visual Necessity via Counterfactual Residuals for Multimodal Medical Data Selection

cs.LG cs.AI ·2026-10-18 ·Haotian Gan, Yudong Li, Xintian Li, Jiarui Han, Weidong Tang
top venuebenchmarkcode/data similarity 0.65
Abstract · Accepted to NeurIPS2026

Medical vision-language models often exhibit hidden stratification, where high overall performance masks failures on subtle visual findings and overlapping clinical conditions. We trace this failure mode to modality imbalance during fine-tuning, where strong linguistic priors can suppress visually grounded learning and induce plausible but weakly grounded rationales. Existing data selection methods usually score image-text pairs as holistic units, without separating visually necessary samples from shortcut-solvable ones. To address this problem, we propose ViCoR, a counterfactual-residual-based data selection method for Med-VLM fine-tuning. ViCoR estimates visual necessity through image-dependent optimization residuals, calibrates the resulting scores with medical supervision compatibility, and constructs a diversity-aware fine-tuning subset. Across two backbones, four external generalization benchmarks, and one multi-disease robustness benchmark, ViCoR-selected 20\% subsets achieve the strongest average performance compared with full-data fine-tuning and selection baselines. Gradient-level analysis and perturbation audits further show that ViCoR enriches image-dependent training signals and strengthens image-level and evidence-region dependence. The code will be available at https://github.com/htgan-ai/ViCoR.

0.40

Is a 9B Decision Foundation Model Needed for Symptom-to-Disease Classification? Fine-Tuning Clef-Flash Against TF-IDF Baselines

cs.CL cs.AI ·2026-10-10 ·S. M. Mahbub Uddin Ahmed
benchmarkcode/data similarity 0.64
Abstract · v2: Corrected reported results against saved experiment outputs; added same-split TF-IDF baselines (which outperform the fine-tuned model); …

Disease classification from patient-reported symptom descriptions is usually approached with lightweight discriminative models or with autoregressive large language models (LLMs), which understand language broadly but generate text token by token and require output parsing. We study decision foundation models, which score a closed set of candidate labels in a single forward pass without generating text. We adapt Clef-Flash, a 9-billion parameter decision model built on a Qwen3.5 backbone, to the 24-class Symptom2Disease benchmark using 4-bit quantized low-rank adaptation (QLoRA) on a stratified split of 960 training and 240 test cases. The fine-tuned model reaches 95.42% accuracy (95% CI 91.98-97.42%) and a macro F1 of 0.9551, up from 65.00% for the unadapted weights (62.92% through the remote API). However, TF-IDF linear SVM and logistic regression baselines trained on the same split reach 98.75% (95% CI 96.39-99.57%) with sub-millisecond CPU inference, so on this benchmark the fine-tuned model offers no accuracy advantage over a well-tuned linear classifier. A Leave-One-Symptom-Out clause-ablation analysis of four illustrative narratives shows predictions depending on distinguishing clauses: in a psoriasis example, removing the clause describing silvery scales lowers the predicted probability from above 99.99% to 0.12% and shifts the prediction to impetigo, while removing other clauses changes it by less than 0.001 percentage points. Decision architectures deliver structured, single-pass predictions from large language backbones, but short, lexically distinctive benchmarks such as Symptom2Disease cannot show an advantage over simple baselines; validation on longer, real clinical text and clinician review are needed.

0.29

Lumen: Parameter-Efficient Alignment of Pretrained Vision and Language Encoders for Zero-Shot Computational Pathology

cs.CV ·2026-09-15 ·Kiarash Tajbakhsh, Abdelrahman Faqieh, Michael Jopiti, Javier Garcia-Baroja, Philipp Zens +7 more
similarity 0.64
Abstract

Pathology vision-language models are commonly built by pretraining or fine-tuning large encoders on paired image-caption data. We asked whether a pathology vision-language model can instead be assembled by parameter-efficient alignment of frozen unimodal foundation models, leaving their pretrained representations untouched. Here we present Lumen, which aligns frozen Virchow2 and BioMedBERT backbones using rank-4 adapters and projection heads, training only 0.40% of the total parameters on the public QUILT-1M corpus. Across nine public zero-shot patch benchmarks, Lumen achieved the highest mean chance-corrected balanced accuracy, 0.546 versus 0.461 for the strongest baseline (paired difference 0.086, 95% CI 0.042-0.136). On lymph-node metastasis detection, Lumen reached an AUROC of 0.964 (95% CI 0.956-0.971) on 4,214 held-out internal slides and 0.955 (95% CI 0.942-0.966) on 2,368 slides across nine external cohorts and six organs. At the internally calibrated threshold, it outperformed all vision-language baselines, with a balanced accuracy of 0.909 (95% CI 0.896-0.923) internally and 0.915 (95% CI 0.902-0.929) externally. Lumen performed competitively across the evaluations, with the exception of cross-modal retrieval, where it ranked third behind CONCH and PathGen-L/14. Fully fine-tuning both encoders gave Lumen no consistent benefit over low-rank adaptation, although it improved retrieval. Aligning frozen unimodal foundation models therefore yields strong and transferable performance at patch and slide level while training only a small fraction of the parameters.

0.15

MedReaMM: Evaluating Large Multimodal Models on Expert-Level Clinical Diagnostic Synthesis

cs.CV ·2026-08-23 ·Lai Wei, Yuchao Chen, Zhenbiao Cao, Xiaojin Zhang, Zhongyu Wei +3 more
top venuebenchmark similarity 0.63
Abstract

The application of Large Language Models (LLMs) to diagnostic decision-making has garnered growing interest. However, existing benchmarks largely focus on textual reasoning or isolated visual question-answering (VQA) tasks, lacking holistic integration of clinical narratives and medical imaging, and thus failing to assess the multimodal diagnostic synthesis capability central to expert clinical judgment. To bridge this gap, we introduce MedReaMM, a benchmark specifically designed to evaluate models' ability to synthesize heterogeneous clinical evidence consisting of detailed patient histories alongside multiple medical images into accurate differential diagnoses under a complete-information paradigm. Constructed from case reports sourced from top-tier medical journals and curated clinical case databases, MedReaMM comprises 625 expert-validated cases with an average of 2.79 medical images per case and a total of 1,042 standardized diagnoses annotated with ICD-11 codes. These cases predominantly represent rare, atypical, or multi-system presentations that demand expert-level evidence integration beyond routine pattern recognition. We evaluate 23 Large Multimodal Models (LMMs) and find that most achieve diagnostic accuracy scores below 50%, underscoring a substantial gap in multimodal diagnostic synthesis capability. Further analysis reveals that medical knowledge proficiency, medical image understanding, and evidence integration are all highly correlated with diagnostic performance.

0.40