Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer

cs.CV ·submitted 2026-10-26 10:06 UTC · v1

Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

Closest papers

Nearest neighbours by meaning across the whole index.

3D CT-to-PET Translation via Latent Brownian Bridge Diffusion

cs.CV cs.AI ·2026-09-11 ·Sarita Mourya, Francesco Di Feola, Pierangelo Veltri, Paolo Soda
similarity 0.82
Abstract

Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and treatment planning. However, the widespread use of PET is limited by high radiation exposure, elevated costs, and restricted availability. To address these limitations, deep learning-based CT-to-PET translation has emerged as a promising approach for synthesizing PET-like information directly from CT images, although accurately modeling the large cross-modal gap remains challenging. In this work, we propose a 3D CT-to-PET translation framework based on latent Brownian Bridge Diffusion (BBDM). The method consists of two stages. First, a Variational Autoencoder (VAE) is trained on paired CT-PET patches, integrating contrastive learning to improve latent alignment between anatomical and metabolic representations. Second, a BBDM is trained in the latent space to translate CT latent representations into their corresponding PET counterparts. The translated PET latents are then decoded and stitched to reconstruct the final 3D PET volume. We evaluate the proposed approach on two publicly available datasets. Quantitative results based on image fidelity and lesion-level PET-specific metrics demonstrate improved performance compared with competing methods. In particular, the proposed approach improves PET signal fidelity, better preserves clinically relevant uptake patterns, and shows improved performance in preserving small-lesion metabolic activation, paving the way for virtual imaging applications.

0.22

Generative Priors for Total-Body PET Reconstruction

eess.IV cs.CV ·2026-09-18 ·Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader
published similarity 0.77
Abstract · MICCAI RIME 2026 (Accepted Poster)

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

0.13

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

cs.CV ·2026-09-15 ·Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo +1 more
similarity 0.75
Abstract

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.

0.08

MedicalDPO: Multi-Objective Direct Preference Optimization for CT to PET Translation

cs.CV ·2026-11-16 ·Huiting Zhang, Yingxin Cai, Siyuan Wang, Xi Yang, Yuyao Yan +2 more
similarity 0.73
Abstract

CT-to-PET synthesis estimates functional PET images from anatomical CT scans for auxiliary analysis, representation pretraining, and missing-modality completion. Brownian Bridge diffusion models can produce multiple PET candidates of different quality under the same CT condition, exposing an intra-condition quality hierarchy. Candidate quality spans complementary spatial, structural, and intensity dimensions, while DPO-only fine-tuning may compromise absolute synthesis fidelity. We propose MedicalDPO which converts this hierarchy into preference supervision automatically constructed from paired CT-PET training data. Multiple candidates are ranked across the three fidelity dimensions, and strict cross-metric verification retains preferred-rejected pairs with consistent quality separation. Relative denoising-error preference optimization is jointly trained with the original Brownian Bridge objective to anchor the pretrained CT-to-PET mapping, while condition-balanced multi-pair rotation distributes preference supervision across CT conditions. Experiments on BBDM and CPDM show improvements across LPIPS, MAE, SSIM, and PSNR. Further analyses demonstrate metric complementarity and clear pair separation, while ablations show that the original training objective prevents the substantial degradation caused by DPO-only fine-tuning.

0.25

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

cs.CV ·2026-11-18 ·Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg +1 more
similarity 0.72
Abstract · 11 pages, 6 figures, 3 tables. Submitted to IEEE Transactions on Radiation and Plasma Medical Sciences

Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps ($μ$-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to $μ$-map synthesis for dynamic cardiac $^{82}$Rb PET. First, a convolutional neural network (CNN) predicts an initial $μ$-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final $μ$-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference $μ$-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.

0.32

Generative Translation Priors: Bayesian Imaging with Cross-Modality Image Translation

eess.IV cs.CVcs.LG ·2026-08-28 ·Evan Bell, Jiaming Liu, Yifan Chen, Yu Sun
code/data similarity 0.72
Abstract · 51 pages, 12 figures. Code is available at https://github.com/Hopkins-CIG/GTP

The ability to leverage images from co-available modalities to inform target-domain reconstruction is highly desirable in imaging algorithms. In this work, we introduce Generative Translation Priors (GTP)--a Bayesian framework that transforms diffusion-based image-to-image translation models into cross-modality image priors for ill-posed imaging inverse problems. GTP incorporates target-domain measurements through likelihood guidance, steering the translation process toward the desired posterior distribution. The framework is grounded in a theoretical analysis of the resulting posterior dynamics, which reveals an intrinsic bias introduced by likelihood guidance. We further characterize this bias and derive a ground-truth-free formulation for its estimation, enabling it to serve as a practical metric for assessing posterior sampling quality. Building on this analysis, we derive two discretized GTP algorithms based on gradient and proximal likelihood guidance, respectively. We validate GTP on computed tomography reconstruction with magnetic resonance side information, and on positron emission tomography reconstruction with computed tomography side information. Experiments demonstrate that GTP effectively incorporates complementary cross-modality information and achieves high-fidelity reconstruction even under severely undersampled measurements.

0.38

Flow Matching-Based PET Image Reconstruction

eess.IV cs.CVphysics.med-ph ·2026-08-20 ·Fumio Hashimoto, Ziqian Huang, Tatsuya Yokota, Kuang Gong
similarity 0.71
Abstract · 10 pages, 8 figures

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.

0.58

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

eess.IV cs.CV ·2026-10-16 ·Shaojun Li, Xiaoyu Deng, Ikuo Keshi
similarity 0.71
Abstract · 21 pages, 7 figures. Supplementary material included. Under review at Biomedical Signal Processing and Control

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

0.17