CS Paper Radar

Generative Priors for Total-Body PET Reconstruction

Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader

eess.IV cs.CV ·submitted 2026-09-18 14:51 UTC · v1
published

Abstract

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

Comment
MICCAI RIME 2026 (Accepted Poster)

Closest papers

Nearest neighbours by meaning across the whole index.

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

cs.CV ·2026-09-15 ·Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo +1 more
similarity 0.81
Abstract

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.

0.08

Flow Matching-Based PET Image Reconstruction

eess.IV cs.CVphysics.med-ph ·2026-08-20 ·Fumio Hashimoto, Ziqian Huang, Tatsuya Yokota, Kuang Gong
similarity 0.78
Abstract · 10 pages, 8 figures

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.

0.58

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.77
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

Bayesian PET Reconstruction with Learned Flow Matching Priors via Langevin Sampling

eess.IV cs.CV ·2026-10-30 ·Hengjia Ran, Huafeng Liu, Bo Zhao
benchmark similarity 0.76
Abstract · Selected as the Best Student Paper Award for 2026 IVMSP

Image reconstruction for positron emission tomography (PET) is a challenging inverse problem due to its inherent ill-posedness and Poisson counting noise, particularly in low-dose acquisitions. In this work, we introduce a novel Bayesian PET reconstruction framework that leverages a flow-matching generative prior learned from high-quality PET images. By incorporating this prior, we formulate PET reconstruction as a Bayesian inference problem and solve it via latent-space posterior sampling using the unadjusted Langevin algorithm. We evaluate the proposed method through numerical experiments and benchmark it against classical reconstruction methods and state-of-the-art deep learning-based baselines. The proposed method achieves improved reconstruction performance while enabling posterior uncertainty quantification.

0.45

Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors

eess.IV ·2026-08-29 ·Hengjia Ran, Jie Luo, Yutao Zhu, Rui Hu, Fenglin Zhan +3 more
similarity 0.74
Abstract

Image reconstruction for positron emission tomography (PET) is an ill-posed Poisson inverse problem. In this work, we introduce an unsupervised, optimization-based reconstruction framework that employs a flow-matching generative model as a learned manifold prior. We train the generative model on high-quality PET images to learn a differentiable ordinary differential equation (ODE)-based transport from a Gaussian latent distribution to the PET image distribution. We incorporate this generator as an explicit manifold constraint into a regularized Poisson likelihood formulation. To solve the resulting problem, we develop an alternating direction method of multipliers (ADMM) algorithm that integrates an expectation-maximization (EM)-type surrogate update for Poisson data fidelity with gradient-based latent-space optimization. Numerical simulations and in vivo PET experiments demonstrate improved reconstruction accuracy compared with conventional reconstruction methods and recent deep learning-based approaches, particularly in low-count settings, with competitive computational efficiency.

0.07

DuSS-PET: Self-Supervised Low-Dose PET Reconstruction Using Pseudo-Dual-Domain Consistency Without Paired Data

cs.CV ·2026-11-08 ·Shuijin Lin, Yuzhu He, Yongbo Wang, Jianhua Ma, Fan Wang
top venuecode/data similarity 0.73
Abstract · Author accepted manuscript. Published in IEEE Transactions on Radiation and Plasma Medical Sciences (Early Access, 2026)

Positron emission tomography (PET) is pivotal in medicine and healthcare, but requires high radiation doses for quality imaging. Although deep learning has shown promise for low-dose PET reconstruction/enhancement, existing methods primarily rely on fully supervised learning, which requires paired low- and full-dose scans that are clinically impractical to obtain. To overcome this fundamental limitation, we propose DuSS-PET, a novel self-supervised PET reconstruction framework that operates without any paired low- and full-dose data. Our method is built upon a computational Noisier2Noise (Nr2N) paradigm, featuring a Bernoulli corruption strategy that serves as an image-space approximation to emulate low-count noise patterns in image-derived pseudo-sinogram representations. The DuSS-PET framework integrates three core components: an adaptive Swin transformer for pseudo-sinogram restoration, a plug-and-play module for image enhancement, and a consistency-constrained SSL strategy that enforces agreement between the pseudo-sinogram and image representations. Extensive experiments on multi-center datasets demonstrate that DuSS-PET achieves superior reconstruction performance, outperforming state-of-the-art SSL methods and achieving comparable or even better results than fully supervised approaches across various dose levels. In particular, it exhibits exceptional generalization across different scanner vendors. This work is among the first self-supervised low-dose PET reconstruction framework that enforces consistency between reconstructed images and pseudo-sinograms, where the pseudo-sinogram generated in the image space serves as a solid computational consistency constraint for enhanced imaging without full-dose training scans. The source code will be publicly available at https://github.com/ladderlab-xjtu/DuSS-PET.

0.48

3D CT-to-PET Translation via Latent Brownian Bridge Diffusion

cs.CV cs.AI ·2026-09-11 ·Sarita Mourya, Francesco Di Feola, Pierangelo Veltri, Paolo Soda
similarity 0.72
Abstract

Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and treatment planning. However, the widespread use of PET is limited by high radiation exposure, elevated costs, and restricted availability. To address these limitations, deep learning-based CT-to-PET translation has emerged as a promising approach for synthesizing PET-like information directly from CT images, although accurately modeling the large cross-modal gap remains challenging. In this work, we propose a 3D CT-to-PET translation framework based on latent Brownian Bridge Diffusion (BBDM). The method consists of two stages. First, a Variational Autoencoder (VAE) is trained on paired CT-PET patches, integrating contrastive learning to improve latent alignment between anatomical and metabolic representations. Second, a BBDM is trained in the latent space to translate CT latent representations into their corresponding PET counterparts. The translated PET latents are then decoded and stitched to reconstruct the final 3D PET volume. We evaluate the proposed approach on two publicly available datasets. Quantitative results based on image fidelity and lesion-level PET-specific metrics demonstrate improved performance compared with competing methods. In particular, the proposed approach improves PET signal fidelity, better preserves clinically relevant uptake patterns, and shows improved performance in preserving small-lesion metabolic activation, paving the way for virtual imaging applications.

0.22

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.72
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.42