CS Paper Radar

Bayesian PET Reconstruction with Learned Flow Matching Priors via Langevin Sampling

Hengjia Ran, Huafeng Liu, Bo Zhao

eess.IV cs.CV ·submitted 2026-10-30 06:51 UTC · v1
benchmark

Abstract

Image reconstruction for positron emission tomography (PET) is a challenging inverse problem due to its inherent ill-posedness and Poisson counting noise, particularly in low-dose acquisitions. In this work, we introduce a novel Bayesian PET reconstruction framework that leverages a flow-matching generative prior learned from high-quality PET images. By incorporating this prior, we formulate PET reconstruction as a Bayesian inference problem and solve it via latent-space posterior sampling using the unadjusted Langevin algorithm. We evaluate the proposed method through numerical experiments and benchmark it against classical reconstruction methods and state-of-the-art deep learning-based baselines. The proposed method achieves improved reconstruction performance while enabling posterior uncertainty quantification.

Comment
Selected as the Best Student Paper Award for 2026 IVMSP
Journal ref
2026 IEEE Image, Video, and Multidimensional Signal Processing Workshop (IVMSP)
DOI
10.1109/IVMSP68335.2026.11618818

Closest papers

Nearest neighbours by meaning across the whole index.

Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors

eess.IV ·2026-08-29 ·Hengjia Ran, Jie Luo, Yutao Zhu, Rui Hu, Fenglin Zhan +3 more
similarity 0.80
Abstract

Image reconstruction for positron emission tomography (PET) is an ill-posed Poisson inverse problem. In this work, we introduce an unsupervised, optimization-based reconstruction framework that employs a flow-matching generative model as a learned manifold prior. We train the generative model on high-quality PET images to learn a differentiable ordinary differential equation (ODE)-based transport from a Gaussian latent distribution to the PET image distribution. We incorporate this generator as an explicit manifold constraint into a regularized Poisson likelihood formulation. To solve the resulting problem, we develop an alternating direction method of multipliers (ADMM) algorithm that integrates an expectation-maximization (EM)-type surrogate update for Poisson data fidelity with gradient-based latent-space optimization. Numerical simulations and in vivo PET experiments demonstrate improved reconstruction accuracy compared with conventional reconstruction methods and recent deep learning-based approaches, particularly in low-count settings, with competitive computational efficiency.

0.07

Flow Matching-Based PET Image Reconstruction

eess.IV cs.CVphysics.med-ph ·2026-08-20 ·Fumio Hashimoto, Ziqian Huang, Tatsuya Yokota, Kuang Gong
similarity 0.80
Abstract · 10 pages, 8 figures

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.

0.58

Generative Priors for Total-Body PET Reconstruction

eess.IV cs.CV ·2026-09-18 ·Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader
published similarity 0.76
Abstract · MICCAI RIME 2026 (Accepted Poster)

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

0.13

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.72
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.42

DuSS-PET: Self-Supervised Low-Dose PET Reconstruction Using Pseudo-Dual-Domain Consistency Without Paired Data

cs.CV ·2026-11-08 ·Shuijin Lin, Yuzhu He, Yongbo Wang, Jianhua Ma, Fan Wang
top venuecode/data similarity 0.69
Abstract · Author accepted manuscript. Published in IEEE Transactions on Radiation and Plasma Medical Sciences (Early Access, 2026)

Positron emission tomography (PET) is pivotal in medicine and healthcare, but requires high radiation doses for quality imaging. Although deep learning has shown promise for low-dose PET reconstruction/enhancement, existing methods primarily rely on fully supervised learning, which requires paired low- and full-dose scans that are clinically impractical to obtain. To overcome this fundamental limitation, we propose DuSS-PET, a novel self-supervised PET reconstruction framework that operates without any paired low- and full-dose data. Our method is built upon a computational Noisier2Noise (Nr2N) paradigm, featuring a Bernoulli corruption strategy that serves as an image-space approximation to emulate low-count noise patterns in image-derived pseudo-sinogram representations. The DuSS-PET framework integrates three core components: an adaptive Swin transformer for pseudo-sinogram restoration, a plug-and-play module for image enhancement, and a consistency-constrained SSL strategy that enforces agreement between the pseudo-sinogram and image representations. Extensive experiments on multi-center datasets demonstrate that DuSS-PET achieves superior reconstruction performance, outperforming state-of-the-art SSL methods and achieving comparable or even better results than fully supervised approaches across various dose levels. In particular, it exhibits exceptional generalization across different scanner vendors. This work is among the first self-supervised low-dose PET reconstruction framework that enforces consistency between reconstructed images and pseudo-sinograms, where the pseudo-sinogram generated in the image space serves as a solid computational consistency constraint for enhanced imaging without full-dose training scans. The source code will be publicly available at https://github.com/ladderlab-xjtu/DuSS-PET.

0.48

Generative Translation Priors: Bayesian Imaging with Cross-Modality Image Translation

eess.IV cs.CVcs.LG ·2026-08-28 ·Evan Bell, Jiaming Liu, Yifan Chen, Yu Sun
code/data similarity 0.69
Abstract · 51 pages, 12 figures. Code is available at https://github.com/Hopkins-CIG/GTP

The ability to leverage images from co-available modalities to inform target-domain reconstruction is highly desirable in imaging algorithms. In this work, we introduce Generative Translation Priors (GTP)--a Bayesian framework that transforms diffusion-based image-to-image translation models into cross-modality image priors for ill-posed imaging inverse problems. GTP incorporates target-domain measurements through likelihood guidance, steering the translation process toward the desired posterior distribution. The framework is grounded in a theoretical analysis of the resulting posterior dynamics, which reveals an intrinsic bias introduced by likelihood guidance. We further characterize this bias and derive a ground-truth-free formulation for its estimation, enabling it to serve as a practical metric for assessing posterior sampling quality. Building on this analysis, we derive two discretized GTP algorithms based on gradient and proximal likelihood guidance, respectively. We validate GTP on computed tomography reconstruction with magnetic resonance side information, and on positron emission tomography reconstruction with computed tomography side information. Experiments demonstrate that GTP effectively incorporates complementary cross-modality information and achieves high-fidelity reconstruction even under severely undersampled measurements.

0.38

Picard Proximal Monte Carlo for Parallel Bayesian Imaging with Score-Based Generative Priors

cs.LG ·2026-08-18 ·Deliang Wei, Evan Bell, Wenhan Guo, Yifan Chen, Yu Sun
similarity 0.68
Abstract

Bayesian imaging inverse problems often require sampling from high-dimensional posterior distributions. While recent score-based and diffusion models provide expressive Bayesian priors, their sampling procedures remain inherently sequential and computationally expensive for large-scale imaging applications. We propose PiX-MC, a time-parallel posterior sampling framework based on proximal Langevin dynamics and Picard iteration. The proximal-likelihood formulation exploits the fact that many imaging likelihoods admit efficient, problem-specific proximal operators, while Picard refinement exposes parallelism across discretization nodes and naturally supports multi-GPU implementation. To further improve practical scalability and sampling performance, we develop multi-block and annealed variants of the proposed framework. We establish convergence guarantees under transparent assumptions, accommodating non-log-concave posteriors, imperfect learned score models, multi-block implementations, and annealing schedules. Experiments on a diverse collection of imaging inverse problems demonstrate that PiX-MC substantially reduces wall-clock time while preserving reconstruction quality. On a $512\times512\times80$ sparse-view computed tomography (CT) problem, annealed multi-block PiX-MC achieves up to a $50\times$ runtime speedup over the standard Langevin sampler using eight GPUs.

0.09

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

cs.CV ·2026-09-15 ·Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo +1 more
similarity 0.68
Abstract

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.

0.08