CS Paper Radar

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

Evgeny Alves Limarenko

eess.IV cs.CVcs.LG ·submitted 2026-11-17 16:40 UTC · v1

Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

Closest papers

Nearest neighbours by meaning across the whole index.

nnFoundation: 3D Foundation Models for Radiology

cs.CV eess.IV ·2026-09-22 ·Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp +78 more
highly cited similarity 0.71
Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

0.42

Representation Learning for 3D Brain Imaging: A Benchmark

cs.CV ·2026-11-04 ·Pierre Falconnier, Robin Trombetta, Nicolas Duchateau, Carole Lartizien
top venuebenchmarkcode/data similarity 0.69
Abstract

Many deep learning architectures for computer vision tasks rely on features extracted by a pre-trained encoder on large databases of natural 2D RGB images. However, the wide domain gap with medical images hampers the direct transfer of optimized deep learning models from computer vision to clinical applications. Recently, self-supervised pre-training and foundation models emerged as promising alternatives to mitigate these limitations. Yet, constructing such models for medical imaging faces critical challenges, including designing and adapting training strategies for large 3D volume datasets, and the need for standardized benchmarks to evaluate feature extraction performance. In this study, we propose an extensive comparison of vision encoders with a focus on 3D brain MRI. First, we consider 8 fully and self-supervised models pretrained on natural images (e.g. ResNet, DINO, CLIP) and 10 backbone architectures trained on medical images, either based on supervised (e.g. RadImageNet) or self-supervised (e.g. BiomedCLIP, SimCLR) tasks. All pre-trained encoders are evaluated on various downstream tasks to assess the representation power of their latent representations, including age and sex prediction as well as disease classification on the ADNI and PPMI datasets. Our study shows that 2D encoders pre-trained on natural images perform the most favorably, even compared to models pre-trained on more than 100k brain MRI volumes, highlighting the need for more suitable and robust methods for representation learning in 3D medical imaging. The source code for this study is publicly available at: https: //github.com/PierreFalconnier/brain-representation-benchmark.

0.50

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

cs.CV physics.med-ph ·2026-11-01 ·Mojtaba Safari, Parag J. Parikh, Shansong Wang, Mingzhe Hu, Philip Connell +4 more
similarity 0.69
Abstract

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

0.21

Scale-Aware 3D Deep Learning for Robust Brain Metastasis Detection in Multimodal MRI

eess.IV cs.CVcs.LG ·2026-09-09 ·Sylvain Jaume, Hongming Wang, Simon K. Warfield
top venue similarity 0.68
Abstract · 12 pages, 3 figures, 3 tables

Detecting brain metastases in magnetic resonance imaging (MRI) remains challenging because lesions vary widely in size and appearance, with very small metastases occupying only a minute fraction of a three-dimensional input. We investigate whether combining different spatial fields of view (FOVs) improves lesion detection in multimodal MRI and present a scale-aware 3D deep-learning framework. The method uses independently trained $96^3$ and $64^3$ 3D U-Nets whose whole-volume probability maps are combined by weighted late fusion. This design allows us to study the effect of spatial context separately from image resolution and modality choice. On a 97-patient development cohort, cross-FOV fusion improved lesion-level precision and F1 while substantially reducing false positives relative to the individual models. A same-FOV ensemble control showed that these gains were not explained solely by averaging independently trained networks, supporting a contribution from complementary spatial context. An exploratory cross-FOV agreement filter reduced false positives but did not improve overall F1. These results support cross-FOV probability fusion as a simple and computationally practical strategy for improving the precision-false-positive trade-off in 3D brain-metastasis detection.

0.35

VoxForge: A Unified Foundation Model for Dense 3D Features Across MRI, CT and PET

cs.CV cs.LG ·2026-11-19 ·Rushil Anirudh, Jayaraman J. Thiagarajan
similarity 0.68
Abstract · 34 pages (8-page main paper, references, and 23-page supplementary material), 7 figures. Rushil Anirudh and Jayaraman J. Thiagarajan contrib…

A unified 3D medical foundation model promises reusable, frozen features that serve a wide variety of tasks such as segmentation, classification and registration on MRI, CT and PET as well as specialist models do. Generalist models still need separate backbones for localized and global tasks, specialist models are confined to a single modality, with the concern that spanning modalities under-emphasizes fine anatomy, and both typically rely on end-to-end fine-tuning to be competitive. We present VoxForge, a single encoder that integrates recent advances in 3D architecture, self-distillation and cross-modal curricula to learn transferable features from permissively licensed MRI and CT volumes. We evaluate it strictly frozen, the test a reusable foundation model must pass, against state-of-the-art generalist and specialist models on segmentation, classification and registration across MRI and CT, and on PET, which it never sees. VoxForge has the best or tied-best average rank in every task group, serves localized and global tasks across modalities at the level of state-of-the-art specialists, and is extremely label-efficient, matching top-performing models on TotalSegmentator CT with a tenth of the labels.

0.17

Pix2Rep-v2: Data-Efficient Representation Learning for Dense Medical Imaging Applications

cs.CV ·2026-09-01 ·S. Sifaoui, E. Angelini, S. Toupin, T. Pezel, L. Le Folgoc
top venuecode/data similarity 0.67
Abstract · Accepted at MICCAI 2026

Dense self-supervised learning (SSL) is a powerful paradigm for learning without annotations the local descriptors required to solve dense medical imaging tasks. We present Pix2Rep-v2, a framework for SSL of pixel- and voxel-level representations suitable for few-shot downstream applications. Pix2Rep-v2 addresses the main challenges of dense SSL by leveraging a redundancy reduction objective at the pixel-level with a principle of equivariance of dense representations, that scales efficiently to 3D or wide field-of-view applications. We evaluate our method on four datasets, across multiple tasks, multiple modalities and anatomical structures using multiple backbones in 2D and 3D, and under various data regimes. As an alternative to linear probing or full fine-tuning on the downstream task, we also propose an in-context variant, without downstream training, based on a dense prototype approach. Pix2Rep-v2 shows substantially higher data-efficiency in few-shot scenarios compared to fully supervised baselines, and is competitive with the state-of-the-art e.g., +9.3 Dice points in one-shot segmentation on the M&Ms-2 dataset. Our code and pre-trained models are publicly available at https://github.com/BioMedTP/pix2rep-v2.

0.76

Comparative Study of Anatomical and Learned Features in AI Models for Structural Brain MRI

cs.CV cs.AI ·2026-09-06 ·Boyang Yu, Miquel Lopez Escoriza, Long Chen, Arjun V. Masurkar, Narges Razavian +1 more
published similarity 0.67
Abstract

In this work, we comprehensively evaluate three popular feature-extraction paradigms in AI-based neuroimaging modeling: (1) computation of anatomical surfaces and volumes, (2) supervised learning with convolutional neural networks (CNNs), and (3) unsupervised pretraining of vision transformer (ViT) foundation models, followed by supervised finetuning. Our study is based on 18 publicly available datasets containing 3D structural T1-weighted MRI scans from approximately 80,000 participants across seven distinct clinical tasks. We observe that a linear model based on anatomical features matches the diagnostic performance of complex nonlinear features learned by sophisticated AI frameworks, including foundation models trained on thousands of scans. Conversely, CNNs and pretrained ViTs learn features that implicitly capture relevant anatomical information, bypassing the need for explicit feature extraction. Building upon these insights, we propose Anatomy Segmentation Pretraining (ASP), a novel method to incorporate anatomical information during foundation-model pretraining, which outperforms existing models in biological age estimation.

0.31

A thorough review on Deep Learning approaches to 2D-to-3D Registration in Medical Imaging

eess.IV cs.CVcs.LGphysics.med-ph ·2026-11-12 ·Andrea Borghesi, Julia van Beurden, Maarten van Alphen, Michiel van den Brekel, Luc Karssemakers +4 more
similarity 0.67
Abstract · 51 pages, 4 tables, 8 figures

2D-to-3D image registration is a key component for several medical imaging purposes such as intraoperative guidance, enabling the alignment between preoperative 3D volumes and real-time 2D images. While conventional optimisation-based methods often struggle with non-convex objectives, sensitivity to initialisation, and high computational demands, deep learning (DL) has emerged as a promising alternative, offering improved alignment robustness and the potential for real-time performance. This review provides a comprehensive analysis of DL frameworks developed to address the challenges inherent in 2D-to-3D registration. We first outline how core concepts of DL are adapted to the registration problem. We then examine recent methodological advancements from multiple perspectives, including pipeline design, architectural innovations, and domain adaptation strategies. Particular attention is given to quantitative metrics, highlighting how performance is defined and measured across studies. Across the 41 included studies, we find that direct regression is the most common pipeline (23 studies, against 18 iterative ones), that hybrid CNN-attention architectures are gaining ground, and that research remains heavily concentrated on X-ray-to-CT registration. We conclude by identifying the absence of per-case uncertainty estimation and the strong neglect of temporal or sequential modelling as the two methodological gaps most consequential for clinical readiness, and discuss state-space models as a way to add temporal memory within intraoperative latency budgets. Further opportunities lie in more principled domain adaptation and in the integration of foundation models for representation learning.

0.19