Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez

cs.CV ·submitted 2026-09-22 22:14 UTC · v1
published

Abstract

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

Comment
12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis

cs.CV ·2026-09-14 ·Wanxian Li, Jiaqian Qin, Qingyi Xian, Yazhi Li, Song Chen +2 more
similarity 0.75
Abstract · 29 pages, 9 figures, including Supplementary Material

Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease.

0.21

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.74
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.73
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29

UI-VISA: U-Net Initialized Vascular Image Segmentation Architecture

cs.CV ·2026-09-01 ·Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
similarity 0.71
Abstract · 9 pages, 6 figures

Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branching nature of blood vessels. Pixel-wise deep learning approaches such as U-Net achieve strong general-purpose segmentation performance but often produce fragmented or discontinuous predictions in fine vascular regions, since they do not explicitly enforce structural connectivity. Region growing algorithms preserve spatial context and topological continuity, but are highly sensitive to seed point initialization and can be computationally expensive. We propose UI-VISA (U-Net Initialized Vascular Image Segmentation Architecture), a hybrid pipeline that combines the complementary strengths of both approaches. UI-VISA uses U-Net's foreground predictions as informed seed points for a CNN-guided region growing algorithm, which then iteratively refines the segmentation by enforcing local connectivity and recovering fine vessel details that U-Net alone tends to miss or over-predict. We evaluate UI-VISA against standalone U-Net and a prior region-growing-based method (VISA) using 5-fold cross-validation on 26 DSA images. UI-VISA achieves the highest mean Dice and clDice scores across folds, and a paired Wilcoxon signed-rank test shows the improvement in clDice is statistically significant ($p=0.023$), consistent with the method's design goal of preserving vascular connectivity, while the improvement in Dice does not reach significance ($p=0.104$).

0.22

Sub-Voxel Displacement and Ipsilateral Territory Decoupling for 3D Bilateral Coronary Artery Tree Reconstruction in Cardiac CT Angiography

cs.CV q-bio.TO ·2026-10-05 ·Zeyu Jia, Xin Ming
similarity 0.70
Abstract · 18 pages, 4 figures, 7 tables; includes combined Supplementary Material (Algorithms A1-A5 and Tables S1-S5)

Reconstructing topologically complete, sub-voxel-accurate 3D bilateral coronary artery trees from cardiac CT angiography (CCTA) requires simultaneously recovering continuous centerline trajectories and separating dense left/right coronary territories without cross-ostial collisions. We present a five-stage tubular drift and ipsilateral territory decoupling framework (M1-M5). Stage M1 pairs a 398,843-parameter multi-scale 3D pyramid encoder with a four-head tubular field network predicting vesselness probability, signed tubular boundary distance, unit tangent vectors, and continuous 3D centripetal displacement vectors. Stage M2 introduces recall-preserving multi-task optimization with 7-group AdamW parameter decoupling, L2-SP backbone regularization, and per-step anchor shrinkage. Stage M3 calibrates cylindrical Valsalva-sinotubular-junction wall coordinates and native-resolution orifice contact expectations for robust left and right ostial rooting. Stage M4 constructs a scalar-potential-weighted minimum-cost arborescence followed by normal-plane cross-sectional pullback and centripetal trajectory pruning. Stage M5 enforces coverage-guarded ipsilateral-field-coupled bilateral collision reduction and subtree handover. Across a 14-case held-out development cohort (Dev-14, 17-arm forward incremental build and 9-arm leave-one-out ablation) and an independent 50-case out-of-sample evaluation cohort (OOS-50) benchmarked against seven external architectures (nnU-Net, 3D UX-Net, Swin-UNETR, MedNeXt, CS2-Net, clDice-UNet, and Point-UNet), M1-M5 reduces bilateral chamfer distance on Dev-14 from 3.4381 mm to 2.2759 mm and achieves 2.7671 mm on OOS-50 with 7.11% bilateral collision rate and 79.7% distal branch completeness.

0.29

Mind the Gap: Mesh-Guided Repair of Broken Vessels

cs.CV ·2026-09-24 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published similarity 0.69
Abstract · Accepted at ShapeMI 2026 (Shape in Medical Imaging), MICCAI 2026 Workshop. 17 pages, 5 figures, 3 tables

Vessel segmentation is commonly optimized as voxel-wise classification, but small local errors can strongly disrupt vascular connectivity while having little effect on overlap scores. This is particularly problematic for downstream analyses that rely on centerlines, branches, connected components, or graph structure. We propose a mesh-guided post-processing framework for repairing broken vessel segmentations produced by nnU-Net. For each predicted binary mask, a deformable template mesh is fitted to the mask surface in physical space and used as a case-specific geometric scaffold. The fitted mesh is not voxelized as the final segmentation; instead, it guides conservative reconnection of disconnected components by proposing or validating thin bridge candidates under foreground-growth constraints. We evaluated this approach in three vascular anatomies using AortaSeg24 and SEGA for the aorta, TopCoW for the Circle of Willis, and PARSE for the pulmonary arteries. Performance is measured using Dice, connected-component Dice (ccDice), and the Betti-0 number. Across these datasets, repair substantially improved connectivity while preserving overlap: Dice remained nearly unchanged, whereas ccDice increased from 0.596 to 0.992 for aorta, from 0.722 to 0.835 for TopCoW, and from 0.028 to 0.862 for PARSE. The FOMAML meta-initialization further accelerated the fitting per-case, supporting practical mesh-based repair of the vascular topology. These results suggest that explicit mesh representations can provide a useful geometric prior for correcting topological failures in otherwise accurate voxel segmentations.

0.33

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
similarity 0.69
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.12

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.68
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23