CS Paper Radar

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo

cs.CV ·submitted 2026-10-07 03:40 UTC · v1
code/data

Abstract

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

Comment
22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Project page with video results: https://G2304138H.github.io/PPCAR-Net/

Closest papers

Nearest neighbours by meaning across the whole index.

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
similarity 0.75
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.12

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections

cs.CG cs.CV ·2026-09-14 ·Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
top venue similarity 0.74
Abstract · 11 pages, 2 figures

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.

0.29

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.73
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

Sub-Voxel Displacement and Ipsilateral Territory Decoupling for 3D Bilateral Coronary Artery Tree Reconstruction in Cardiac CT Angiography

cs.CV q-bio.TO ·2026-10-05 ·Zeyu Jia, Xin Ming
similarity 0.71
Abstract · 18 pages, 4 figures, 7 tables; includes combined Supplementary Material (Algorithms A1-A5 and Tables S1-S5)

Reconstructing topologically complete, sub-voxel-accurate 3D bilateral coronary artery trees from cardiac CT angiography (CCTA) requires simultaneously recovering continuous centerline trajectories and separating dense left/right coronary territories without cross-ostial collisions. We present a five-stage tubular drift and ipsilateral territory decoupling framework (M1-M5). Stage M1 pairs a 398,843-parameter multi-scale 3D pyramid encoder with a four-head tubular field network predicting vesselness probability, signed tubular boundary distance, unit tangent vectors, and continuous 3D centripetal displacement vectors. Stage M2 introduces recall-preserving multi-task optimization with 7-group AdamW parameter decoupling, L2-SP backbone regularization, and per-step anchor shrinkage. Stage M3 calibrates cylindrical Valsalva-sinotubular-junction wall coordinates and native-resolution orifice contact expectations for robust left and right ostial rooting. Stage M4 constructs a scalar-potential-weighted minimum-cost arborescence followed by normal-plane cross-sectional pullback and centripetal trajectory pruning. Stage M5 enforces coverage-guarded ipsilateral-field-coupled bilateral collision reduction and subtree handover. Across a 14-case held-out development cohort (Dev-14, 17-arm forward incremental build and 9-arm leave-one-out ablation) and an independent 50-case out-of-sample evaluation cohort (OOS-50) benchmarked against seven external architectures (nnU-Net, 3D UX-Net, Swin-UNETR, MedNeXt, CS2-Net, clDice-UNet, and Point-UNet), M1-M5 reduces bilateral chamfer distance on Dev-14 from 3.4381 mm to 2.2759 mm and achieves 2.7671 mm on OOS-50 with 7.11% bilateral collision rate and 79.7% distal branch completeness.

0.29

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.71
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.68
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.68
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.67
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23