Abstract

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

Comment
12

Closest papers

Nearest neighbours by meaning across the whole index.

Local2Mesh: Spatially Localized Contour-to-Mesh for Left Ventricular Reconstruction from Sparse 2D Cardiac MRI

cs.CV cs.AI ·2026-10-05 ·Haoyu Wu, Ling Lin, Pascal Lefèvre, Ruizhe Li, Xiaowu Sun
code/data similarity 0.74
Abstract · submit to ICASSP 2027

Three-dimensional (3D) left ventricular (LV) reconstruction from sparse cardiac magnetic resonance (CMR) imaging remains challenging due to inter-slice misalignment and insufficient local spatial information between slices. Global aggregation of contour features may obscure local contour-to-surface relationships. We propose Local2Mesh, a spatially localized contour-to-mesh framework that deforms a template mesh to reconstruct 3D LV geometry from sparse 2D contours without 3D mesh annotations. The framework introduces geometry-aware alignment to correct inter-slice misalignment and a plane-aware Local Router that routes contour features to template vertices using vertex-to-plane distances. Local and global contour features then jointly guide graph-based template deformation for 3D LV reconstruction. Experiments on two public datasets, M\&Ms-2 and ACDC, demonstrate superior geometric reconstruction and functional estimation over existing methods. Zero-shot transfer from M\&Ms-2 to ACDC demonstrates strong cross-dataset generalization. Reconstructed meshes also improve disease classification over sparse contours, supporting their utility for downstream cardiac analysis. These results demonstrate that combining geometry-aware alignment with local contour-to-vertex modeling improves LV reconstruction from sparse 2D contours and supports downstream cardiac analysis. The code is available at https://github.com/hwu918945-alt/loca2mesh.

0.24

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections

cs.CG cs.CV ·2026-09-14 ·Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
top venue similarity 0.71
Abstract · 11 pages, 2 figures

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.

0.29

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.68
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29

MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision

cs.CV ·2026-09-08 ·Quanxin Zheng, Shuai Zhao
code/data similarity 0.67
Abstract

Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. We evaluate three weak-mask generators -- LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning -- and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.928 Dice and 3.80mm HD95 with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.

0.24

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
similarity 0.66
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.12

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

cs.CV ·2026-08-19 ·Arnaud Boutillon, Naomi Clarke, Tomas Woodgate, Daniel West, Alina Schneider +6 more
similarity 0.65
Abstract

Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container https://hub.docker.com/r/aboutill/sparc and is currently deployed at our institution as a clinical research tool.

0.37

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.65
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.65
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16