CS Paper Radar

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein, Miaomiao Zhang

eess.IV cs.LG ·submitted 2026-11-05 04:08 UTC · v1
code/data

Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

Closest papers

Nearest neighbours by meaning across the whole index.

CardioTrace: Motion-Aware Cine Synthesis via Coupled Tracing and Segmentation

cs.CV ·2026-11-13 ·Zhi Chen, Le Zhang
hot direction similarity 0.77
Abstract

Cardiac cine MRI provides time-resolved visualization of cardiac motion and is essential for evaluating ventricular function and anatomy. In routine clinical acquisition, however, cine sequences are frequently temporally sparse or degraded by arrhythmia, motion, and scan-time constraints, which can hinder reliable quantification and downstream analysis. We present CardioTrace, a motion-aware cine synthesis framework that generates a full cardiac cine sequence from limited input while explicitly modeling and tracing cardiac motion. CardioTrace couples two complementary pathways: a pixel-translation branch that directly predicts cine frames in a residual formulation, and a flow-field branch that estimates time-resolved deformation fields from a reference phase to provide interpretable motion correspondences across frames. To further preserve anatomical plausibility, a segmentation branch supervises clinically meaningful cardiac structures at key phases, and a cross-branch consistency objective encourages the synthesized appearance dynamics to follow the explicit motion guidance, mitigating temporal drift and unrealistic shape transitions over long sequences. The framework also supports prompt-style conditioning to incorporate auxiliary patient or acquisition information, improving robustness across heterogeneous multi-center data. Experiments on public cardiac cine MRI datasets demonstrate that CardioTrace improves perceptual quality and temporal coherence over representative GAN- and diffusion-based baselines, while better preserving ventricular morphology throughout the cardiac cycle. \textit{Our codes are available after review}.

0.17

EchoDiST: Self-distillation-based joint learning for diffusion-conditioned echocardiographic myocardial motion estimation

cs.CV ·2026-10-08 ·Feiyue Qi, Xingyue Wei, Jianwen Luo
similarity 0.77
Abstract · 19 pages, 14 figures

Motion estimation in echocardiography is essential for quantitative assessment of cardiac function and myocardial mechanics, but remains challenging due to image artifacts, limited image information, speckle decorrelation, and the scarcity of ground-truth displacement fields. Anatomy-guided approaches can provide structural information, yet often rely on expert-labeled myocardial segmentations. We propose EchoDiST, a framework for unsupervised echocardiographic myocardial motion estimation that integrates self-distillation-based joint learning with a diffusion-conditioned motion estimation network. Here, unsupervised motion estimation refers to learning without ground-truth displacement fields. The self-distillation strategy jointly optimizes anatomical segmentation and myocardial motion estimation under limited anatomical annotations. Diffusion-based conditioning is used during training with stochastic perturbations, while inference requires only a single deterministic forward pass without iterative reverse-diffusion sampling. EchoDiST was evaluated on three echocardiographic datasets, including two external test datasets under cross-view and cross-dataset settings. Compared with seven representative learning-based methods, EchoDiST consistently improved anatomical alignment, myocardial strain assessment, and motion-derived functional and cardiac-phase assessment. These gains were statistically significant across the evaluated tasks and datasets. Overall, EchoDiST provides an effective approach for reliable myocardial motion estimation under limited anatomical supervision and supports downstream quantitative assessment of cardiac function.

0.21

Phase-Aligned Finite-Fourier Periodic Deformation for 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Zhiheng Ma, Mingyang Ou, Heng Li +1 more
top venue similarity 0.71
Abstract · ACMMM 2026 accepted

4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in applications such as cardiac MRI and thoracic CT, where motion is often repetitive or near-periodic over clinically relevant intervals. A key challenge is that this structure is not always encoded directly in deformation representations for interpolation. In addition, physiological motion is often non-uniform, so equal temporal intervals do not necessarily correspond to equal amounts of anatomical change. To address these issues, we formulate interpolation as learning a continuous deformation process with a phase-structured prior. Given two endpoint volumes, we parameterize a phase-conditioned velocity field with a finite Fourier basis, which embeds near-periodic motion patterns directly into the deformation space and supports continuous querying at arbitrary target times. We further introduce a phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression. Intermediate volumes are then synthesized by continuously warping both endpoints, followed by bidirectional fusion and lightweight residual refinement. Experiments on ACDC and 4D-Lung show that the proposed method achieves state-of-the-art performance over existing baselines while producing anatomically plausible and coherent intermediate volumes from sparse observations.

0.66

One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching

cs.CV ·2026-10-07 ·Shiyi Wang, Ruochen Sun, Peirong Liu, Xiang Li, Fangxu Xing
benchmark similarity 0.71
Abstract

Cine cardiovascular magnetic resonance (CMR) analysis relies on multi-frame sequences capturing the full cardiac cycle. However, standard multi-frame acquisition depends heavily on electrocardiogram (ECG) gating and repeated breath-holds, posing challenges in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing methods that synthesize full cardiac sequences either rely on explicit ECG signals to parameterize myocardium function, or employ deformable registration without physiological constraints, failing to faithfully reproduce clinically relevant dynamic metrics such as ejection fraction (EF) and ventricular contraction magnitude. We present PhaseFlow, a unified generative framework that overcomes both limitations. PhaseFlow estimates a non-linear cardiac phase signal directly from the input sequence via a segmentation-derived left-ventricular (LV) area curve, capturing the asymmetric dynamics of systole and diastole without any ECG dependency. At inference, this phase signal is provided by a pathology-specific template, informing phase-specific frame generation. A rectified flow model conditioned on the phase and slice position synthesizes the full cardiac motion trajectory in the latent space, decoded into a diffeomorphic displacement field that warps end-diastole pixel intensities directly, eliminating the reconstruction blur often accompanying the variational autoencoder. On the ACDC benchmark, PhaseFlow achieves superior physiological fidelity and image realism, with best LV volume curve $R^2$, structural similarity (SSIM) and generative quality (FID) among all baselines. Ablation studies confirm that each proposed component contributes measurably to the overall performance.

0.15

One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow Matching

cs.CV ·2026-10-06 ·Shiyi Wang, Ruochen Sun, Xiang Li, Peirong Liu, Fangxu Xing
benchmark similarity 0.70
Abstract

Cine cardiovascular magnetic resonance (CMR) captures the cardiac cycle as a four-dimensional (4D) sequence, but standard acquisition requires electrocardiogram (ECG) gating and repeated breath holds. Visual realism alone does not establish accurate patient-specific ejection fraction (EF) or ventricular volumes. We present PhaseFlow3D, a generative framework that synthesizes a complete 4D cine sequence from a single end-diastolic (ED) three-dimensional (3D) volume without ECG. To capture asymmetric systolic and diastolic dynamics, it represents the cardiac cycle as a piecewise linear phase anchored at ED and end-systolic (ES) time points. At inference, a population-level canonical template supplies this phase without patient-specific temporal information. A phase-conditioned rectified flow model generates a cardiac motion trajectory in latent space. Radial Contraction Decomposition converts each latent state into a 3D displacement field, combining a physics-informed radial component for centripetal myocardial contraction with an image-conditioned residual for rotation and out-of-plane motion. Each frame is generated by directly warping the ED volume, bypassing variational autoencoder decoding. On the combined ACDC and M&Ms benchmark, PhaseFlow3D achieves the lowest EF mean absolute error, the only positive left-ventricular volume-curve $R^2$, and the best distributional quality among compared methods. Ablations confirm each component's contribution. Downstream evaluations demonstrate the utility of the synthesized sequences and displacement fields for segmentation, pathology classification, label propagation, and myocardial strain analysis.

0.23

SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation

cs.CV physics.med-ph ·2026-09-11 ·Lila Cunge
similarity 0.69
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.

0.12

AI-Based Multi-View Echocardiographic Image Synthesis using Dynamic Shape Control

cs.CV cs.AI ·2026-11-13 ·João Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge +1 more
published similarity 0.68
Abstract · 5 pages, 2 figures, accepted for publication in the Proceedings of the 2026 IEEE International Ultrasonics Symposium (IUS 2026)

Although automated methods have improved echocardiographic workflows, progress remains constrained by the need for large, well-annotated datasets. As the development of clinical databases is often limited by ethical and logistical challenges, synthetic data generation has emerged as a promising alternative. However, existing approaches commonly rely on left ventricle shape-based supervision or are tailored to specific cardiac views, limiting the generation of additional standard and unconventional imaging planes and the preservation of multi-view consistency across cardiac chambers. To address these limitations, we propose a novel framework for shape-controlled synthesis of multi-view echocardiographic sequences. First, multi-view cross-sections are extracted from dynamic whole-heart meshes. Ultrasound-like appearance is then introduced through a two-stage AI-based pipeline. In Stage 1, an unpaired GAN-diffusion model translates these cross-sections into realistic echocardiographic frames. As this translation is performed independently at the frame level, Stage 2 employs masked video reconstruction to improve temporal coherence and cardiac motion. Evaluation demonstrated high frame-level realism for both stages, while the integration of Stage 2 substantially improved video-level motion quality and temporal consistency. Overall, the proposed framework enables the generation of realistic multi-view echocardiographic sequences from diverse cardiac models, providing a scalable source of annotated data for dataset augmentation and the development of multi-view cardiac assessment methods.

0.33

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

cs.CV ·2026-11-02 ·Yusuf A. Ozturk, Jie Zheng, Fanwei Kong
similarity 0.68
Abstract

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

0.04