CS Paper Radar

One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching

Shiyi Wang, Ruochen Sun, Peirong Liu, Xiang Li, Fangxu Xing

cs.CV ·submitted 2026-10-07 03:56 UTC · v1
benchmark

Abstract

Cine cardiovascular magnetic resonance (CMR) analysis relies on multi-frame sequences capturing the full cardiac cycle. However, standard multi-frame acquisition depends heavily on electrocardiogram (ECG) gating and repeated breath-holds, posing challenges in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing methods that synthesize full cardiac sequences either rely on explicit ECG signals to parameterize myocardium function, or employ deformable registration without physiological constraints, failing to faithfully reproduce clinically relevant dynamic metrics such as ejection fraction (EF) and ventricular contraction magnitude. We present PhaseFlow, a unified generative framework that overcomes both limitations. PhaseFlow estimates a non-linear cardiac phase signal directly from the input sequence via a segmentation-derived left-ventricular (LV) area curve, capturing the asymmetric dynamics of systole and diastole without any ECG dependency. At inference, this phase signal is provided by a pathology-specific template, informing phase-specific frame generation. A rectified flow model conditioned on the phase and slice position synthesizes the full cardiac motion trajectory in the latent space, decoded into a diffeomorphic displacement field that warps end-diastole pixel intensities directly, eliminating the reconstruction blur often accompanying the variational autoencoder. On the ACDC benchmark, PhaseFlow achieves superior physiological fidelity and image realism, with best LV volume curve $R^2$, structural similarity (SSIM) and generative quality (FID) among all baselines. Ablation studies confirm that each proposed component contributes measurably to the overall performance.

Closest papers

Nearest neighbours by meaning across the whole index.

One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow Matching

cs.CV ·2026-10-06 ·Shiyi Wang, Ruochen Sun, Xiang Li, Peirong Liu, Fangxu Xing
benchmark similarity 0.84
Abstract

Cine cardiovascular magnetic resonance (CMR) captures the cardiac cycle as a four-dimensional (4D) sequence, but standard acquisition requires electrocardiogram (ECG) gating and repeated breath holds. Visual realism alone does not establish accurate patient-specific ejection fraction (EF) or ventricular volumes. We present PhaseFlow3D, a generative framework that synthesizes a complete 4D cine sequence from a single end-diastolic (ED) three-dimensional (3D) volume without ECG. To capture asymmetric systolic and diastolic dynamics, it represents the cardiac cycle as a piecewise linear phase anchored at ED and end-systolic (ES) time points. At inference, a population-level canonical template supplies this phase without patient-specific temporal information. A phase-conditioned rectified flow model generates a cardiac motion trajectory in latent space. Radial Contraction Decomposition converts each latent state into a 3D displacement field, combining a physics-informed radial component for centripetal myocardial contraction with an image-conditioned residual for rotation and out-of-plane motion. Each frame is generated by directly warping the ED volume, bypassing variational autoencoder decoding. On the combined ACDC and M&Ms benchmark, PhaseFlow3D achieves the lowest EF mean absolute error, the only positive left-ventricular volume-curve $R^2$, and the best distributional quality among compared methods. Ablations confirm each component's contribution. Downstream evaluations demonstrate the utility of the synthesized sequences and displacement fields for segmentation, pathology classification, label propagation, and myocardial strain analysis.

0.23

CardioTrace: Motion-Aware Cine Synthesis via Coupled Tracing and Segmentation

cs.CV ·2026-11-13 ·Zhi Chen, Le Zhang
hot direction similarity 0.79
Abstract

Cardiac cine MRI provides time-resolved visualization of cardiac motion and is essential for evaluating ventricular function and anatomy. In routine clinical acquisition, however, cine sequences are frequently temporally sparse or degraded by arrhythmia, motion, and scan-time constraints, which can hinder reliable quantification and downstream analysis. We present CardioTrace, a motion-aware cine synthesis framework that generates a full cardiac cine sequence from limited input while explicitly modeling and tracing cardiac motion. CardioTrace couples two complementary pathways: a pixel-translation branch that directly predicts cine frames in a residual formulation, and a flow-field branch that estimates time-resolved deformation fields from a reference phase to provide interpretable motion correspondences across frames. To further preserve anatomical plausibility, a segmentation branch supervises clinically meaningful cardiac structures at key phases, and a cross-branch consistency objective encourages the synthesized appearance dynamics to follow the explicit motion guidance, mitigating temporal drift and unrealistic shape transitions over long sequences. The framework also supports prompt-style conditioning to incorporate auxiliary patient or acquisition information, improving robustness across heterogeneous multi-center data. Experiments on public cardiac cine MRI datasets demonstrate that CardioTrace improves perceptual quality and temporal coherence over representative GAN- and diffusion-based baselines, while better preserving ventricular morphology throughout the cardiac cycle. \textit{Our codes are available after review}.

0.17

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.71
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

cs.CV ·2026-09-10 ·John Bonnici, Matthew Baugh, Aleksandra Kulbaka, Sarah Cechnicka, Bernhard Kainz +1 more
publishedcode/data similarity 0.70
Abstract · Accepted for oral presentation at the ASMUS workshop at MICCAI 2026

Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/

0.31

Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation

cs.AI ·2026-10-06 ·Onur Selim Kilic, Afra Nawar, Cem Okan Yaldiz, Michael J. Cho, Ahmet Rasim Emirdagi +4 more
similarity 0.67
Abstract

Paired translation between quasiperiodic physiological waveforms (i.e., recovering a target oscillatory signal from the source) is central to the interpretation of cardiovascular signals derived from wearables placed at different body locations. This source-to-target mapping in these problems carries inherent geometric structure: the phase wraps around the cycle and must be treated as a circular variable, the amplitude remains strictly positive, and the beat-to-beat alignment can drift unpredictably across cycles and subjects. While deep neural networks have been used for phase estimation and complex-valued signal modeling, prior work does not explicitly learn phase transport between paired signals. Consequently, neither endpoint-supervised regression nor the standard affine path used in flow matching accounts for this phase--amplitude structure. We introduce \emph{cylindrical geodesic flow matching} for paired cardiovascular waveform translation. We show that the standard affine path used in flow matching distorts intermediate amplitude and instantaneous frequency when interpolating between quasiperiodic signals; replacing it with a closed-form geodesic on the phase--amplitude cylinder eliminates these artifacts and converts each training pair into dense, geometry-consistent velocity supervision. On zero-shot photoplethysmography and limited-support seismocardiography adaptation benchmarks, our method consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction, reducing Hilbert Transform, $L_2$, and Dynamic Time Warping distance by up to ${\sim}15\%$ over the strongest competing baseline. These results suggest that bridge geometry is a critical inductive bias for flow matching on oscillatory signal translation.

0.30

Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

eess.IV cs.CV ·2026-10-13 ·Junkai Liu, Haofan Wu, Nay Aung, Joao A. C. Lima, Steffen E. Petersen +1 more
publishedcode/data similarity 0.67
Abstract · NeurIPS 2026. Project page: https://cardiofad.github.io/

Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus--Align--Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability--alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG--visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.

0.33

Phase-Aligned Finite-Fourier Periodic Deformation for 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Zhiheng Ma, Mingyang Ou, Heng Li +1 more
top venue similarity 0.66
Abstract · ACMMM 2026 accepted

4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in applications such as cardiac MRI and thoracic CT, where motion is often repetitive or near-periodic over clinically relevant intervals. A key challenge is that this structure is not always encoded directly in deformation representations for interpolation. In addition, physiological motion is often non-uniform, so equal temporal intervals do not necessarily correspond to equal amounts of anatomical change. To address these issues, we formulate interpolation as learning a continuous deformation process with a phase-structured prior. Given two endpoint volumes, we parameterize a phase-conditioned velocity field with a finite Fourier basis, which embeds near-periodic motion patterns directly into the deformation space and supports continuous querying at arbitrary target times. We further introduce a phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression. Intermediate volumes are then synthesized by continuously warping both endpoints, followed by bidirectional fusion and lightweight residual refinement. Experiments on ACDC and 4D-Lung show that the proposed method achieves state-of-the-art performance over existing baselines while producing anatomically plausible and coherent intermediate volumes from sparse observations.

0.66

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.66
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25