CS Paper Radar

Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation

Onur Selim Kilic, Afra Nawar, Cem Okan Yaldiz, Michael J. Cho, Ahmet Rasim Emirdagi, Demet Tangolar, Amirali Aghazadeh, Amit J. Shah, Omer T. Inan

cs.AI ·submitted 2026-10-06 15:15 UTC · v1

Abstract

Paired translation between quasiperiodic physiological waveforms (i.e., recovering a target oscillatory signal from the source) is central to the interpretation of cardiovascular signals derived from wearables placed at different body locations. This source-to-target mapping in these problems carries inherent geometric structure: the phase wraps around the cycle and must be treated as a circular variable, the amplitude remains strictly positive, and the beat-to-beat alignment can drift unpredictably across cycles and subjects. While deep neural networks have been used for phase estimation and complex-valued signal modeling, prior work does not explicitly learn phase transport between paired signals. Consequently, neither endpoint-supervised regression nor the standard affine path used in flow matching accounts for this phase--amplitude structure. We introduce \emph{cylindrical geodesic flow matching} for paired cardiovascular waveform translation. We show that the standard affine path used in flow matching distorts intermediate amplitude and instantaneous frequency when interpolating between quasiperiodic signals; replacing it with a closed-form geodesic on the phase--amplitude cylinder eliminates these artifacts and converts each training pair into dense, geometry-consistent velocity supervision. On zero-shot photoplethysmography and limited-support seismocardiography adaptation benchmarks, our method consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction, reducing Hilbert Transform, $L_2$, and Dynamic Time Warping distance by up to ${\sim}15\%$ over the strongest competing baseline. These results suggest that bridge geometry is a critical inductive bias for flow matching on oscillatory signal translation.

Closest papers

Nearest neighbours by meaning across the whole index.

One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching

cs.CV ·2026-10-07 ·Shiyi Wang, Ruochen Sun, Peirong Liu, Xiang Li, Fangxu Xing
benchmark similarity 0.67
Abstract

Cine cardiovascular magnetic resonance (CMR) analysis relies on multi-frame sequences capturing the full cardiac cycle. However, standard multi-frame acquisition depends heavily on electrocardiogram (ECG) gating and repeated breath-holds, posing challenges in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing methods that synthesize full cardiac sequences either rely on explicit ECG signals to parameterize myocardium function, or employ deformable registration without physiological constraints, failing to faithfully reproduce clinically relevant dynamic metrics such as ejection fraction (EF) and ventricular contraction magnitude. We present PhaseFlow, a unified generative framework that overcomes both limitations. PhaseFlow estimates a non-linear cardiac phase signal directly from the input sequence via a segmentation-derived left-ventricular (LV) area curve, capturing the asymmetric dynamics of systole and diastole without any ECG dependency. At inference, this phase signal is provided by a pathology-specific template, informing phase-specific frame generation. A rectified flow model conditioned on the phase and slice position synthesizes the full cardiac motion trajectory in the latent space, decoded into a diffeomorphic displacement field that warps end-diastole pixel intensities directly, eliminating the reconstruction blur often accompanying the variational autoencoder. On the ACDC benchmark, PhaseFlow achieves superior physiological fidelity and image realism, with best LV volume curve $R^2$, structural similarity (SSIM) and generative quality (FID) among all baselines. Ablation studies confirm that each proposed component contributes measurably to the overall performance.

0.15

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

cs.CV ·2026-09-10 ·John Bonnici, Matthew Baugh, Aleksandra Kulbaka, Sarah Cechnicka, Bernhard Kainz +1 more
publishedcode/data similarity 0.65
Abstract · Accepted for oral presentation at the ASMUS workshop at MICCAI 2026

Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/

0.31

Cyclostationary Phase Conditioning for Medical Time Series Diffusion

cs.LG cs.AIeess.SP ·2026-09-28 ·Samuel Ruiperez-Campillo, Michele Copetti, Jorge da Silva Goncalves, Sonia Laguna, Thomas Hofmann +1 more
similarity 0.65
Abstract · 43 pages, 16 figures, 21 tables

Many physiological time series, such as cardiac and brain recordings, exhibit cyclostationarity: their statistics vary periodically with an underlying cycle phase. Corruption from motion, poor contact, and physiological interference obscures morphology needed for diagnosis, making signal restoration essential. Existing diffusion approaches condition on corrupted observations alone and must learn cyclic structure implicitly. We instead propose two inductive biases which encode cyclostationarity: a shift-covariant wavelet representation and dense per-sample phase conditioning inferred from the corrupted input. We further introduce a training-free cyclostationarity index that quantifies phase structure and predicts when phase conditioning will help. Finally, we propose antithetic coupling of reverse trajectories to reduce sampling variance while achieving comparable performance with fivefold fewer network evaluations. Across modalities, our results show that explicitly encoding measurable cyclic structure improves physiological time-series restoration.

0.45

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.64
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement

cs.CV ·2026-09-30 ·Bo Zhao, Junzhe Cao, Dan Guo, Dongmin Huang, Wenjin Wang +3 more
similarity 0.62
Abstract

Remote photoplethysmography (rPPG) enables non-contact physiological measurement but remains vulnerable to domain shifts from illumination, motion, and sensors. We propose \textbf{FLOW (Feature-Level Optimal Warping)}, an \emph{optimal transport--driven} framework for domain-generalized rPPG. FLOW integrates a \textbf{Temporal Refinement Module (TRM)} to stabilize temporal dynamics and a \textbf{Prototype-based Cross-Temporal Optimal Transport (PCOT)} module to achieve domain-invariant alignment via learnable prototypes.Beyond feature alignment, FLOW employs soft cross-temporal correspondence modeling that aligns temporal features in a flexible manner, allowing the model to respect and preserve the intrinsic rhythmic patterns of physiological signals. Moreover, the lightweight design of our modules allows seamless integration into existing end-to-end rPPG architectures without additional preprocessing. Two regularization terms further enforce source consistency and identity preservation. Theoretically, we derive a generalization bound under conditional optimal transport. Extensive experiments across four rPPG benchmarks show that FLOW achieves state-of-the-art cross-domain performance with lightweight design and strong physiological fidelity.

0.43

Capturing Cardiac Cyclicity through Phase-Equivariant Self-Supervised Learning

cs.LG ·2026-08-21 ·Blaise Delaney, Dominic Dootson, Juan Jose Juan Castella, Salil Patel, Andrew Pfaff +3 more
similarity 0.61
Abstract

The cyclic structure of physiological processes offers a natural prior for self-supervised representation learning, and the cardiac cycle provides a particularly well-defined setting in which to exploit it. We derive a phase-equivariant self-supervised objective and introduce Winder, a joint-embedding architecture that organises representations into phase-invariant coordinates and phase-rotating harmonic subspaces. Its transport operator is fixed and closed-form, derived from the cycle's geometry rather than learned, and adds no parameters. Evaluated on PTB-XL under a frozen linear-probe protocol, Winder attains diagnostic accuracy within the range reported by state-of-the-art self-supervised methods at a ~1 M parameter footprint, while exhibiting phase-equivariant latent geometry. These findings demonstrate that explicitly encoding cardiac-phase symmetry can preserve diagnostically useful information while yielding a latent geometry that is legible, parameter-efficient, and directly tied to a measurable physiological quantity.

0.12

Pulseflow: PPG Counterfactual Generation Via Latent Transport

cs.LG ·2026-09-27 ·Hung Manh Pham, Dong Ma, Bin Zhu, Pan Zhou
code/data similarity 0.60
Abstract

Photoplethysmography (PPG) has become an important modality for continuous cardiovascular monitoring, including atrial fibrillation (AF) detection. However, labeled AF recordings remain limited in many clinical settings, making model adaptation difficult when only limited target data are available. Generative modeling offers a natural way to alleviate this scarcity by synthesizing additional AF signals. Existing approaches, however, mainly generate samples that match the target condition without explicitly modeling how an observed source recording should be transformed, making it difficult to leverage abundant source recordings from a specific population or cohort for targeted augmentation. We introduce PulseFlow, a source-conditioned counterfactual generation framework that combines conditional representation learning with invertible latent transport to edit cardiac rhythm while retaining information from the source. Experiments across two clinical cohorts demonstrate effective rhythm transformation, measurable source correspondence, and improved AF classification under limited labels.

0.24

Functional Autoencoders for Amplitude-Phase Representation Learning

cs.LG stat.ML ·2026-09-28 ·Peida Wu, Xinyang Xiong, Pengcheng Zeng
theorycode/data similarity 0.59
Abstract · 26 pages, 13 figures

Functional data are intrinsically infinite-dimensional, and often exhibit phase variation, where corresponding events occur at different times across observations. Existing linear dimension reduction methods struggle with nonlinear amplitude variation, while functional autoencoders without an explicit warp entangle temporal misalignment with shape. We propose the Amplitude--Phase Functional Autoencoders (AP-FAE), an unsupervised framework for functional data that spans both univariate and multivariate cases, with emphasis on the multivariate setting, and factorizes the latent space into separate amplitude and phase embeddings derived from all channels. A smooth functional decoder reconstructs channel-specific amplitude functions in canonical time, and a shared monotone, endpoint-preserving warp captures phase variation. We prove a bound linking amplitude recovery to registration, reconstruction, and noise errors, and validate it numerically. Across synthetic data and six real-world benchmarks, AP-FAE outperforms state-of-the-art baselines on most clustering and alignment metrics and on all reconstruction metrics. Clustering with amplitude embeddings alone consistently surpasses joint amplitude--phase clustering, confirming the benefit of explicit disentanglement. Code is available at https://anonymous.4open.science/r/APFAE-418C/}{https://anonymous.4open.science/r/APFAE-418C/.

0.41